• Designed to International (IEC) Standards for use globally.
• Meets the IEC 60127-2, Sheet 1 specification for Fast Acting Fuses.
• Available in Cartridge and Axial Lead Form.
• Available in ratings of 0.050 to 10 amperes.
• High breaking capacity.
ELECTRICAL CHARACTERISTICS:
% of Ampere Ampere Opening
Rating Rating Time
150% .05–6.3 60 minutes, Minimum
8-16 30 minutes, Minimum
210% .05–16 30 minutes, Maximum
275% .05–4 0.01 sec., Min.; 2 sec. Max.
5–6.3 0.01 sec., Min.; 3 sec. Max.
8-16 0.04 sec., Min.; 20 sec. Max.
400% .05–6.3 .003 sec., Min.; 0.3 sec. Max.
8-16 .01 sec., Min.; 1.0 sec. Max.
1000% .05–6.3 .02 seconds, Maximum
8-16 .03 seconds, Maximum
INTERRUPTING RATING:
0.05 - 10A 1500A @ 250 VAC, 0.7-0.8 power factor
ORDERING INFORMATION:
Cartridge Nominal Nominal
Catalog Ampere Voltage Resistance Melting I2t
Number Rating Rating Cold Ohms A2Sec.
216.050 .050 250 15.900 0.00019
216.063 .063 250 10.450 0.00054
216.080 .080 250 7.885 0.00084
216.100 .100 250 5.793 0.00450
216.125 .125 250 3.675 0.00545
216.160 .160 250 5.349 0.00576
216.200 .200 250 3.350 0.00438
216.250 .250 250 2.350 0.00891
216.315 .315 250 1.850 0.015
216.400 .400 250 0.903 0.036
216.500 .500 250 0.847 0.169
216.630 .630 250 0.466 0.179
216.800 .800 250 0.295 0.288
216 001 1 250 0.237 0.180
216 1.25 1.25 250 0.153 0.477
216 01.6 1.6 250 0.111 1.008
216 002 2 250 0.076 1.870
216 02.5 2.5 250 0.058 2.697
216 3.15 3.15 250 0.037 6.700
216 004 4 250 0.025 14.996
216 005 5 250 0.018 27.460
216 06.3 6.3 250 0.014 56.429
216 008 8* 250 0.010 64.316
216 010 10* 250 0.008 154.339
ENVIRONMENTAL SPECIFICATIONS:
Operating temperature: -55˚C to 125˚C
Thermal Shock: MIL-STD-202F Method 107G, Test Condition B: (5
cycles –65°C to +125°C)
Vibration: MIL-STD-202F Method 201A
Humidity: MIL-STD-202F Method 103B, Test Condition A. high relative
humidity (95%) and elevated temperature (40°C) for 240 hours.
Salt Spray: MIL-STD-202F Method 101D, Test Condition B
PHYSICAL SPECIFICATIONS:
Material: Body: Ceramic
Cap: Nickel Plated Brass
Leads: Tin Plated Copper
Filler Sand (160mA – 10A)
Terminal Strength: MIL-STD-202F Method 211A,
Test Condition A
Solderability: Reference IEC 60127 Second Edition 2003-01 Annex A
Product Marking: Cap 1: current and voltage rating.
Cap 2: Agency approval markings.
Packaging: Available in Bulk (V=5, H=100, M=1000 pcs/pkg) or on
Tape/Reel (MRET1=1000 pcs/reel).