1
LES010YE-A
45
50
55
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
EFF. (18v)
EFF. (24v)
EFF. (36v)
50
55
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
Efficiency vs. Load (48V Input)
Setpoint Accuracy ±1%
Line Regulation Vin Min. - Vin Max., Iout Rated 0.2%
Vout
Load Regulation Iout Min. - Iout Max., Vin Nom. 0.5% Vout
Minimum Output Current 10% Iout Rated
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 2% Vout
Settling Time 500 ms
Voltage Trim Range ±10%
Short Circuit / Overcurrent Protection Shutdown / Hiccup
Current Limit Threshold Range, % of Iout Rated 110 - 150%
Short Circuit Current Max. 200% Iout
(12Vout & 15Vout : 4.0A when Vout= 0.25V)
Ovp Trip Range 115 -140% Vout Nom.
Ovp Type Second Control Loop
Industry Standard Package
Industry Standard Pinout
100°C Case Operation
Short Circuit Protection
24V and 48V Inputs
Input Pi Filter and
6-Sided Shielding
Regulated Outputs
1500V Isolation
DESCRIPTION FEATURES
Efficiency vs. Load (24V Input)
Voltage Range
24 VDC Nominal 18 - 36 VDC
48 VDC Nominal 36 - 75 VDC
Reflected Ripple 50 mA
Input
Output
General
Turn-On Time 10 ms
Remote Shutdown Positive/Negative Logic
Switching Frequency 400 kHz
Isolation
Input - Output 1500 VDC
Output - Case 500 VDC
Temperature Coefficient 0.02 ppm/°C
Case Temperature
Operating Range -40 To +100°C
Storage Range -40 To +100°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz
MTBF(Bellcore TR-NWT-000332) 2.5 X 106hrs
Safety UL, cUL, TUV
Notes
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load,
unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
LES SERIES - 15 WATT
LES DC/DC converters provide up to 15 watts of output power in
an industry-standard package and footprint. With a maximum
case temperature of 100°C, the LES is well suited for the most
demanding telecom, networking, and industrial applications. The
LES features 1500VDC isolation, short circuit, and over-
temperature protection, as well as six-sided shielding. The LES is
available with optional enable and voltage trim pins. Please see
the IAD Series for dual output applications.
TECHNICAL SPECIFICATIONS
Rev. NOV 13, 2002
2
MODEL INPUT VOLTAGE INPUT VOLTAGE MAXIMUM INPUT OUTPUT RATED OUTPUT RIPPLE & NOISE TYPICAL
(VOLTS) RANGE (VOLTS) CURRENT (AMPS)* VOLTAGE (VOLTS) CURRENT (AMPS) pk-pk (mV) EFFICIENCY**
LES008YD 24 18-36 0.6 2.5 3.00 75 77%
LES010YE 24 18-36 0.8 3.3 3.00 100 81%
LES015YG 24 18-36 1.1 5 3.00 100 84%
LES015YH 24 18-36 1.3 12 1.25 120 85%
LES015YJ 24 18-36 1.3 15 1.00 150 86%
LES008ZD 48 36-75 0.35 2.5 3.00 75 77%
LES010ZE 48 36-75 0.4 3.3 3.00 100 81%
LES015ZG 48 36-75 0.6 5 3.00 100 83%
LES020ZG-3N 48 40-60 0.63 5 4.00 100 84%
LES015ZH 48 36-75 0.65 12 1.25 120 86%
LES015ZJ 48 36-75 0.65 15 1.00 150 86%
NOTES: * Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
LES SERIES - 15 WATT


 

 
 

















MECHANICAL DRAWING
Natural Convection 15.4 °C/W
100 LFM 12.2 °C/W
200 LFM 9.3 °C/W
300 LFM 7.4 °C/W
400 LFM 6.4 °C/W
Tolerances
Note:
Thermal impedance data is
dependent on many environmen-
tal factors. The exact thermal
performance should be validated
for specific application.
Pin Function
1+Vin
2 -Vin
3 no pin
(Optional shutdown
Pin)
4 +Vout
5 no pin
(Optional Trim Pin)
6 -Vout
Inches: (Millimeters)
.XX ± 0.020 .X ± 0.5
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
Case:
+ 0.04, - 0.00 + 1.0, - 0.00
(Dimensions as listed unless otherwise
specified.)
MODELS - (See the last page of section for options.)
Thermal Impedance
Rev. NOV 13, 2002
3
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD TTL "High" Turns Module OFF
Lucent-Compatible Trim T HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Pin Length and Heatsink Options Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length 8 All Leaded Models
0.150" (3.8mm) Pin Length 9 All Leaded Models
0.24" (6.1mm) Horizontal Heatsink 1H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.24" (6.1mm) Vertical Heatsink 1V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heatsink 2H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Vertical Heatsink 2V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heatsink 3H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Vertical Heatsink 3V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer
and add them to the model number. Example ordering options are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional President
of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
OPTIONS
REV. AUG 16, 2002