AC axial fan - HyBlade®
sickled blades (S series)
with guard grille for short nozzle
S4E500-AM03-01
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
County court Stuttgart · HRB 590142
Nominal data
Type S4E500-AM03-01
Motor M4E110-GF
Phase 1~ 1~
Nominal voltage VAC 230 230
Frequency Hz 50 60
Type of data definition ml ml
Valid for approval / standard CE CE
Speed min-1 1300 1400
Power input W 680 880
Current draw A 3.0 3.88
Motor capacitor µF 12 12
Capacitor voltage VDB 450 450
Max. back pressure Pa 150 100
Min. ambient temperature °C -40 -40
Max. ambient temperature °C 65 40
ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit
Subject to alterations
Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive No
Specific ratio*1.00
*Specific ratio = 1 + pfs / 100 000 Pa
Actual Request 2013 Request 2015
Overall efficiency ηes % 32.5 28.5 32.5
Efficiency grade N 40 36 40
Power input PekW 0.65
Air flow qvm³/h 5765
Pressure increase pfs Pa 129
Speed n min-1 1315
Data definition with optimum efficiency. LU-107128
The ErP data is determined using a motor-impeller combination in a standardised measurement configuration.
Item no. 10081-5-9980 · Revision 82542 · Release 2014-05-08 · Page 1 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)
with guard grille for short nozzle
S4E500-AM03-01
Technical features
Size 500 mm
Surface of rotor Coated in black
Material of terminal box PC/ABS plastic, black
Material of blades Press-fitted sheet steel blank, sprayed with PP plastic
Material of guard grille Steel, phosphated and coated in black plastic
Number of blades 5
Direction of air flow "V"
Direction of rotation Counter-clockwise, seen on rotor
Type of protection IP 54
Insulation class "F"
Humidity class F4-1
Max. permissible ambient motor
temp. (transp./ storage)
+ 80 °C
Min. permissible ambient motor
temp. (transp./storage)
- 40 °C
Mounting position Shaft horizontal or rotor on bottom; rotor on top on request
Condensate discharge holes Rotor-side
Operation mode S1
Motor bearing Ball bearing
Touch current acc. IEC 60990
(measuring network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads Via terminal box, integrated capacitor connected via terminal box
Motor protection Thermal overload protector (TOP) brought out
Cable exit Axial
Protection class I (if protective earth is connected by customer)
Product conforming to standard EN 61800-5-1; CE
Approval CSA C22.2 Nr.100; EAC; UL 1004-1; VDE
Item no. 10081-5-9980 · Revision 82542 · Release 2014-05-08 · Page 2 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)
with guard grille for short nozzle
S4E500-AM03-01
Product drawing
1 Direction of air flow "V"
2 Tightening torque 0.8±0.15 Nm
3 Cable diameter: min. 6 mm, max. 12 mm, tightening torque: 2.0±0.3 Nm
Item no. 10081-5-9980 · Revision 82542 · Release 2014-05-08 · Page 3 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)
with guard grille for short nozzle
S4E500-AM03-01
Connection screen
L = U1 = blue Z brown N = U2 = black
PE green / yellow TOP grey
Item no. 10081-5-9980 · Revision 82542 · Release 2014-05-08 · Page 4 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)
with guard grille for short nozzle
S4E500-AM03-01
Charts: Air flow 50 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]
9.0008.0007.0006.0005.0004.0003.0002.0001.0000
qv[cfm]
5.0004.0003.0002.0001.0000
p f s[Pa]
190
185
180
175
170
165
160
155
150
145
140
135
130
125
120
115
110
105
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
pfs _E[IN H2O]
0,76
0,74
0,72
0,7
0,68
0,66
0,64
0,62
0,6
0,58
0,56
0,54
0,52
0,5
0,48
0,46
0,44
0,42
0,4
0,38
0,36
0,34
0,32
0,3
0,28
0,26
0,24
0,22
0,2
0,18
0,16
0,14
0,12
0,1
0,08
0,06
0,04
0,02
0
p f s[Pa]
1
2
3
4
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
Measured values
1
2
3
4
U
V
230
230
230
230
f
Hz
50
50
50
50
n
min-1
1380
1355
1330
1300
Pe
W
513
571
623
680
I
A
2.25
2.50
2.73
3.00
LpAin
dB(A)
68
65
63
65
LwAin
dB(A)
75
72
70
72
LwAout
dB(A)
75
72
70
71
qv
m3/h
8905
7930
6705
5140
pfs
Pa
0
50
100
150
U = Supply voltage · f = Frequency · n = Speed · Pe= Power input · I = Current draw · LpAin = Sound pressure level inlet side · LwAin = Sound power level inlet side · LwAout = Sound power level outlet side
qv = Air flow · pfs = Pressure increase
Item no. 10081-5-9980 · Revision 82542 · Release 2014-05-08 · Page 5 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
AC axial fan - HyBlade®
sickled blades (S series)
with guard grille for short nozzle
S4E500-AM03-01
Charts: Air flow 60 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]
13.00012.00011.00010.0009.0008.0007.0006.0005.0004.0003.0002.0001.0000
qv[cfm]
7.0006.0005.0004.0003.0002.0001.0000
p f s[Pa]
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
pfs _E[IN H2O]
0,8
0,75
0,7
0,65
0,6
0,55
0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0
p f s[Pa]
1
2
3
4
Air performance measured as per ISO 5801
Installation category A. For detailed
information on the measuring set-up, please
contact ebm-papst. Suction-side noise
levels: LwA measured as per ISO 13347 /
LpA measured with 1m distance to fan axis.
The values given are valid under the
measuring conditions mentioned above and
may vary according to the actual installation
situation. With any deviation from the
standard set-up, the specific values have to
be checked and reviewed with the unit
installed.
Measured values
1
2
3
4
U
V
230
230
230
230
f
Hz
60
60
60
60
n
min-1
1530
1485
1450
1400
Pe
W
793
828
853
880
I
A
3.45
3.61
3.73
3.88
LpAin
dB(A)
70
68
66
65
LwAin
dB(A)
77
75
73
72
LwAout
dB(A)
78
75
73
72
qv
m3/h
9850
8990
8220
7300
pfs
Pa
0
40
70
100
U = Supply voltage · f = Frequency · n = Speed · Pe= Power input · I = Current draw · LpAin = Sound pressure level inlet side · LwAin = Sound power level inlet side · LwAout = Sound power level outlet side
qv = Air flow · pfs = Pressure increase
Item no. 10081-5-9980 · Revision 82542 · Release 2014-05-08 · Page 6 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com