IEC and British Standard fuses -- 5 Contents Bussmann series IEC cylindrical fuses Section page Description Fuses CSA Type P and D fuses (CDN, CDS and PON) 2 HRC Form II Class C fuses (CGL) 3 HRCI industrial ceramic body fuses HRCI-CA (CIF21) 4 HRCI-CB (CIF06) HRCI-Misc. Type K (CIH, CIK and CIL) HRC Form II current-limiting fuses (H07C, K07C, L14C, M14C, L09C, M09C, P09C, P11C, R11C) 5 6 BS88 Part 1 fuses SSD, NSD, ESD STD, NITD, AAO, BAO, OSD, CEO, DEO 7 BS88 EF, FF, FG, GF, GG, GH DIN Type D Diazed (D16, D27, D33, D125) DIN Type N Neozed (NZ01, NZ02) 8 9 NH HRC fuses (NHG) 10-11 JKS-700 fast-acting, current limiting UL Recognized and CSA Component Acceptance 700 Vac fuses up to 60 amps 11 NH fuse blocks and accessories (SD, TD) 12 Fuses continued IEC 60269 industrial fuses with and without indicator/striker Complete portfolio of 8-22 mm diameter Class aM and Class gG cylindrical fuses for industrial applications Class gG ferrule (C10G, C14G, C22G) 13 Class aM ferrule (C10M, C14M, C22M) 14 HRC fuse holders CAMaster SAFEloc 15 Red Spot BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries 5-1 IEC and British Standard fuses AC, AD, BC, BD, CD, DD, ED, EFS 5 -- IEC and British Standard fuses CDN, CDS and PON CSA Type P and D fuses Dimensions -- in (mm) A CSA time-delay Type D and P fuses. B Ratings ** Volts ** 250 Vac (CDN and PON) ** 600 Vac (CDS) Up to 60 A Amps 10-600 A ** IR 10 kA minimum CSA Certified to C22.2 No. 59.1, CE Features Economical fuse in a variety of ratings for applications not requiring time-delay Typical applications ** Lighting, heating and other circuits not subject to temporary surges and where available short-circuit current are relatively low Catalog no.* Catalog symbol Volts Available amp ratings Time-Delay CSA Type "D" fuses CDN** CDS 250 Vac 10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600 600 Vac 10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125, 150,175, 200, 225, 250, 300, 350, 400, 450, 500, 600 One-time CSA Type "P" fuses PON 250 Vac E 70 to 600 A Agency information ** B F ** ** A D C 15, 20, 25, 30, 35, 40, 45, 50, 60 * To order, specify catalog symbol and amp rating, e.g., CDN30, CDS110 or PON40. ** Below 10 amps, use FRN-R. Below 10 amps, use FRS-R. Amps A CDN/PON 250 Vac Up to 30 2.0 (51) 35-60 3.0 (76) 70-100 5.9 (149) 110-200 7.3 (185) 225-400 8.6 (219) 450-600 10.4 (264) CDS 600 Vac Up to 30 5.0 (127) 35-60 5.5 (140) 70-100 7.9 (200) 110-200 9.6 (245) 225-400 11.6 (295) 450-600 13.4 (340) B C D E 0.6 (14) 0.8 (21) -- -- -- -- -- -- 1.0 (25) 1.4 (35) 1.9 (48) 2.3 (57) -- -- -- -- -- 0.1 (3) 4.1 (105) 0.2 (5) 4.6 (118) 0.3 (6) 5.2 (132) 0.3 (6) -- -- 0.8 (19) 1.1 (29) 1.6 (41) 2 (51) 0.8 (21) 1.1 (27) -- -- -- -- -- -- 1.0 (25) 1.4 (35) 1.9 (48) 2.3 (57) -- -- -- 6.1 (116) 7.1 (118) 8.2 (208) -- -- 0.8 (19) 1.1 (29) 1.6 (41) 2 (51) -- -- 0.1 0.2 0.3 0.3 F (3) (5) (6) (6) Recommended fuse blocks Catalog no.* Volts Fuse amps 250 600 Up to 30 HM25030-(poles) HM60030-(poles) 35-60 HM25060-(poles) HM60060-(poles) 70-100 HM25100-(poles) HM60100-(poles) 110-200 HM25200-(poles) HM60200-(poles) 225-400 HM25400-(poles) HM60400-(poles) 450-600 HM25600-(poles) HM60600-(poles) * To order, specify 1, 2 or 3 poles, e.g., HM25030-2_. See data sheets 10289 (30-60 A) and 3192 (70-600 A) for available terminals. Data sheet no. 4126 5-2 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries IEC and British Standard fuses -- 5 CGL HRC Form II Class C fuses Dimensions -- in (mm) Current-limiting HRCII-C fuses designed to withstand inrush currents on typical motor start-ups while offering high current limitation in the short-circuit region. See drawings for dimensions. 0.22 0.81 0.22 (5.56) (20.64) (5.56) 0.06 2.0 2.80 ** (84.14) CGL 1-30 0.22 ** 600 Vac ** 250 Vdc (1-30 A) Amps 1-600 A ** IR ** 200 kA ** 40 kA DC (23.81) 3.31 Volts ** 0.94 (8.73) (71.04) Ratings (1.59) 0.34 (50.8) 0.81 0.22 (5.56) (20.64) (5.56) 0.06 2.0 (1.59) 0.50 (50.8) 2.80 1.06 (12.7) (71.04) (26.92) 3.5 (88.9) CGL 35-60 0.343 1.34 0.343 (8.71) (34.04) (8.71) Agency information 2.39 CSA Certified, C22.2 No. 106, Class 1422,File 53787, CE (60.72) 3.64 0.09 (2.29) 0.75 1.375 (19.05) (34.93) (92.47) 4.31 Catalog no. (amps) (109.54) CGL-1 CGL-25 CGL-80 CGL-225 CGL-2 CGL-30 CGL-90 CGL-250 CGL-3 CGL-35 CGL-100 CGL-300 CGL-4 CGL-40 CGL-110 CGL-350 CGL-6 CGL-45 CGL-125 CGL-400 CGL-10 CGL-50 CGL-150 CGL-450 CGL-15 CGL-60 CGL-175 CGL-500 CGL-20 CGL-70 CGL-200 CGL-600 0.343 0.343 (8.71) (8.71) 3.00 0.125 0.75 (76.2) (19.05) 4.30 (109.22) Close sizing to loads allows using smaller and less costly switches ** Provides a higher degree of short-circuit protection ** Helps protect motors against burnout from overloads (38.1) 5.31 (134.87) 0.19 (4.76) 1.0 (25.4) (9.53) ** (3.18) 1.50 CGL 110-200 0.38 Features 1.0 3.0 (25.4) 2.38 (76.2) (60.33) 5.25 (133.35) 8.19 (207.96) Typical applications ** CGL 70-100 IEC and British Standard fuses ** CGL 225-400 For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads 1.0 0.41 (25.4) (10.32) Available Red Spot fuse holders Fuse amps Catalog symbol* Up to 32 RS32_ 35-60 RS63_ 70-100 RS100_ 110-200 RS200_ 225-400 RS400_ 1.0 (25.4) 0.60 3.0 (76.2) 5.25 (133.35) 8.19 (15.24) 0.375 (9.53) 3.00 (76.2) (207.96) CGL 450-600 * See Red Spot data sheet no. 10083 for terminal options. Data sheet no. 4125 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries 5-3 5 -- IEC and British Standard fuses CIF21 HRCI-CA industrial ceramic body fuses CIF06 HRCI-CB industrial ceramic body fuses The HRCI-CA bolt-on, ceramic body fuse provides both overload and short-circuit protection to HRCI requirements. Offset blades for bolt-on mounting CIF21 fuse fits the Bussmann series Red Spot fuse holder (data sheet 10083) and CAMaster fuse holder (data sheet number 4132). A miniature offset clip-in blade, ceramic body industrial fuse that provides both short-circuit and overload protection and the CIF06 fits the 30 A SAFEloc fuse holder (data sheet number 4133). Ratings ** ** Ratings Volts ** 600 Vac Volts ** 600 Vac ** 250 Vdc 250 Vdc ** Amps 1-30 A ** Amps 1-30 A ** IR 200 kA RMS Sym. ** IR 200 kA RMS Sym. Agency information ** Agency information ** ** CSA C22.2, No. 106-M92, CE Catalog no. Amps Catalog no. Amps 1CIF21 1 15CIF21 15 3CIF21 3 20CIF21 20 6CIF21 6 25CIF21 25 10CIF21 10 30CIF21 30 Features CSA C22.2 No. 106-M92 (3-30 A only), CE Catalog no. Amps Catalog no. Amps 1CIF06 1 15CIF06 15 3CIF06 3 20CIF06 20 6CIF06 6 25CIF06 25 10CIF06 10 30CIF06 30 Features ** Close sizing to loads allows using smaller and less costly switches Close sizing to loads allows using smaller and less costly switches ** Provides a higher degree of short-circuit protection ** Provides a higher degree of short-circuit protection ** Helps protect motors against burnout from overloads ** Helps protect motors against burnout from overloads Typical applications ** Typical applications ** ** For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads Recommended fuse holders Amps Description Catalog no.* Up to 20 Red Spot RS20_(terminal option) Up to 30 CAMaster CM20CF For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loads Recommended fuse holders Amps Description Catalog no.* Up to 30 SAFEloc C30(terminal option) * See data sheet no. 4133 for SAFEloc details. Dimensions -- in (mm) * See data sheet no. 10083 (Red Spot) and 4132 (CAMaster) for details. 2.38 (60) 1.44 (36) Dimensions -- in (mm) 0.54 (14) 0.03 (4) 0.44 (11) 0.19 (5) 1.75 (45) Data sheet no. 4127 5-4 0.5 (13) 0.54 (14) 2.15 (55) 1.44 (36) 0.14 (4) 0.03 (1) Data sheet no. 4128 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries IEC and British Standard fuses -- 5 CIH, CIK and CIL HRCI -- Misc. Type K fuses Misc. Type K HRCI bolt-on, ceramic body fuses provide both overload and short-circuit protection, featuring offset blades for bolt down mounting. Ratings ** Volts 600 V ** Amps 1-100 A ** IR 200 kA@600 V Agency information ** CSA C22.2 No. 106-M92, CE Catalog no. (amp)CIH, CIK, CIL 1CIH07 15CIH07 35CIK07 80CIL14 3CIH07 20CIH07 40CIK07 90CIL14 6CIH07 25CIH07 50CIK07 100CIL14 10CIH07 30CIH07 60CIK07 Dimensions -- in (mm) K F A D J E G B H IEC and British Standard fuses L C G The CIL14 has a rejection hole, not a slot as shown above. Amps Up to 30 35- 60 80100 A 2.25 (57) 2.28 (58) 2.75 (70) B 0.94 (24) 1.06 (27) 1.44 (37) C 3.38 (86) 3.56 (91) 4.38 (111) D 0.38 (10) 0.5 (13) 0.75 (19) E 0.04 (1) 0.05 (1) 0.09 (3) F 2.88 (73) 2.88 (73) 3.69 (94) G 0.21 (5) 0.21 (5) 0.34 (9) H 0.31 (8) 0.41 (11) 0.41 (11) J 1 (25) 1.09 (28) 1.5 (39) K 0.10 (3) 0.13 (3) -- L 2.38 (60) 2.38 (61) 2.91 (74) Recommended fuse holders Amps Red Spot* CAMaster* Up to 30 RS32_ CM30CF 35-60 RS63_ CM60CF 80-100 RS100_ -- * See data sheet no. 10083 (Red Spot) and 4132 (CAMaster) for details. Data sheet no. 4130 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries 5-5 5 -- IEC and British Standard fuses HRC Form II current-limiting fuses Dimensions -- in (mm) J E H C H07C offset blades Volts ** 600 Vac (or less) ** 250 Vdc F A G J E D B ** Amps 2-600 A ** IR 200 kA RMS Sym. H C K07C, K07CR, L14C, M14C offset blades Agency information ** D B Ratings ** F A G HRC Form II bolt-on, ceramic body current-limiting fuses. C A H G B D CSA C22.2 No. 106-M92, BS88:2, IEC 60269:2, CE (amps) catalog no. E F L09C, M09C, P09C center blades H07C offset blades 2H07C 6H07C 15H07C 25H07C 4H07C 10H07C 20H07C 30H07C K K F A G B D K07C offset blades 40K07C 60K07C 50K07C 80K07CR 100K07CR L14C offset blades 80L14C 100L14C M14C offset blades 125M14C* 150M14C* 200M14C* L09C center blades 80L09C* 100L09C* M09C center blades 125M09C 150M09C 200M09C P09C center blades 250P09C* 300P09C* 350P09C* 400P09C* 350P11C 400P11C P11C center blades 250P11C 300P11C R11C center blades 450R11C 500R11C 600R11C * Not suitable for installation in Red Spot fuse holders. Typical applications ** H C P11C, R11C center blades Used to protect motor control circuits, together with contactors and overload protection relays to provide Type 2 coordination per IEC 60947-4. Catalog symbol/ style A B H07C offset blades 1.38 0.56 2-30 (35) (14) K07C offset blades 2.19 0.88 40-60 (56) (22) 2.19 0.88 80-100 (56) (22) L14C offset blades 2.38 0.88 80-100 (60) (21) M14C offset blades 2.56 1.5 125-200 (65) (38) L09C center blades 2.38 0.88 80-100 (60) (21) M09C center blades 2.56 1.5 125-200 (65) (38) P09C center blades 3.06 2.31 250-400 (178) (59) P11C center blades 3.06 2.31 250-400 (178) (59) R11C center blades 3.19 2.88 450-600 (81) (73) C D E F G E H J 3.38 0.38 0.06 2.88 0.22 0.31 0.56 -- (85) (9) (1) (73) (6) (8) (14) 3.44 (87) 3.75 (95) 0.5 (13) 0.5 (13) 0.06 (1) 0.06 (1) 2.88 (73) 2.88 (73) 0.22 (6) 0.22 (6) 0.31 (8) 0.31 (8) 0.88 -- (22) 0.88 -- (22) HRCII-C HRCII-C HRCIIMISC -- HRCII-C 4.38 0.75 0.09 3.69 0.34 0.44 -- (111) (19) (2) (94) (9) (11) -- HRCIIMISC 5 0.56 0.13 4.38 0.34 0.44 -- (127) (14) (3) (111) (9) (11) -- HRCIIMISC 5.38 0.75 0.13 4.38 0.34 0.56 -- (136) (19) (3) (111) (9) (14) -- HRCII-C 5.38 1 0.19 4.38 0.34 0.5 (136) (25) (5) (111) (9) (13) -- HRCIIMISC -- 8.25 1 0.19 5.25 0.41 0.63 -- (210) (25) (5) (133) (10) (16) 1 HRCII-C (25) 8.25 1 0.25 5.25 0.41 0.63 -- (210) (25) (6) (133) (10) (16) 1 HRCII-C (25) Data sheet no. 4131 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 CSA category 4.38 0.56 0.13 3.69 0.34 0.44 1 (111) (14) (3) (94) (9) (11) (25) Recommended fuse holders: Red Spot up to 400 amps (data sheet no.10083) and CAMaster up to 100 amps (data sheet no. 4132). 5-6 K Eaton.com/bussmannseries IEC and British Standard fuses -- 5 SSD, NSD, ESD BS88 Part 1 fuses The NSD and ESD are low voltage offset blade, ceramic body fuses complying with general purpose gG characteristics. Ratings Volts 240-550 Vac ** Amps ** The STD to DEO type ceramic body, offset bolt-on blade low voltage fuses complying with general purpose gG characteristics. Ratings ** 2-63 A ** 20M25 to 63M100 motor starter ratings ** Volts 240-550 Vac ** Amps IR ** 33 kA (SSD) ** 80 kA (NSD, ESD) ** Agency information ** Meets the requirements of BS88 Part 1 and IEC 60269-1, CE ** Amps (class) Max Vac BS88 ref. SSD 2, 4, 6, 10, 16, 20, 25, 32 (gG) 240 E1 2, 4, 6, 10, 16, 20, 25, 32 (gG) 550 NSD ESD 20M25, 20M32, 20M36, 32M36, 32M40, 32M50, 32M63 (gM) 415 2, 4, 6, 10, 16, 20, 25, 32 (gG) 550 40, 50, 63 (gG) 415 63M80, 63M100 (gM) * To order, specify catalog symbol and amp rating, e.g., SSD20. "M" indicates motor starter ratings. 2-200 A ** 20M25 to 200M315 motor starter ratings IR ** 33 kA (STD) ** 80 kA (NITD, AAO, BAO, CEO, DEO, OSD) Agency information Catalog no.* Catalog symbol ** Meets the requirements of BS88 Part 1 and IEC 60269-1, CE Catalog no.* Catalog symbol Amps (class) Max Vac BS88 ref. STD 2, 4, 6, 10, 16, 20, 25, 32 (gG) 240 -- F1 2, 4, 6, 10, 16, 20, 25, 32 (gG) NITD F2 AAO BAO Recommended fuse holders Fuse symbol Catalog no. NSD 32NNSF ESD 63ENSF CEO DEO OSD 20M25, 20M32 (gM) 550 32M40, 32M50, 32M63 (gM) 415 2, 4, 6, 10, 16, 20, 25, 32, (gG) 550 32M40, 32M50, 32M63 (gM) 500 40, 50, 63 (gG) 63M80, 63M100 (gM) 500 32, 40, 50, 63, 80, 100 (gG) 550 100M125, 100M160, 100M200 (gM) 415 125, 160, 200 (gG) 415 200M315 (gM) 80, 100 (gG) 500 100M125, 100M160 (gM) 415 -- A2 A3 A4 -- -- * To order, specify basic catalog symbol and amp rating. E.g., BAO16. "M" indicates motor starter ratings. Typical applications ** The STD type are used in 240 V street lighting cut-outs ** NITD to DEO types used for industrial and general purpose applications Recommended fuse blocks and holders Fuse catalog symbol Block/holder catalog no.* NITD CM32FC, RS20_ AAO CM32F, RS32_ BAO CM63F, RS63_ OSD CM100F, RS100_ CEO BH-0111 * See data sheet no. 4132 (CM_), 10083 (RS_) and 1200 (BH-_). Data sheet no. 4105 (SSD), 4100 (NSD) and 4101 (ESD) Data sheet no. 4123 (STD), 4106 (NITD), 4109 (AAO), 4112 (BAO), 4107 (OSD), 4115 (CEO) and 4117 (DEO) BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries 5-7 IEC and British Standard fuses ** STD, NITD, AAO, BAO, OSD, CEO, DEO BS88 Part 1 fuses 5 -- IEC and British Standard fuses AC, AD, BC, BD, CD, DD, ED, EFS BS88 fuses EF, FF, FG, GF, GG, GH BS88 fuses Ceramic body, center blade two-hole bolt-on low voltage fuses that comply with general purpose gG characteristics and available up to 400 amps with two hole mount and up to 1250 amps with four hole mount. Ceramic body, center blade four-hole bolt-on low voltage fuses complying with general purpose gG characteristics and available up to 400 amps with two hole mount and up to 1250 amps with four hole mount. Ratings Ratings (see catalog numbers table) ** ** ** Volts ** ** 415/550 Vac ** 415/690 Vac ** 250 Vdc ** 250/400 Vdc Amps ** 2-400 A ** 63M80 to 400M500 motor starter ratings Catalog no.* IR ( kA) Max volts Catalog symbol AC DC AC 80 40 Amps (class) 2, 4, 6, 10, 16, 20 (gG) 25, 32 (gG) 2, 4, 6, 10, 16, 20 (gG) AD 25, 32 (gG) BC BD 40, 50, 63 (gG) 63M80, 63M100 (gM) 40, 50, 63 (gG) 80 40 80 40 80 40 80 -- 80 -- 80 -- CD80, CD100 (gG) CD DD 100M125, 100M160, 100M200 (gM) 125, 160, 200 (gG) 200M250, 200M315 (gM) 250, 315, 355, 400 (gG) ED 315M400 (gM) 400M500 (gM) EFS Amps 355-1250 A ** IR see catalog numbers table ** Meets the requirements of BS88 Parts 1 and 2 and IEC 60269-1, CE AC ** Agency information IR see catalog numbers table Agency information ** Volts 550 500 550 IR ( kA) Max volts Catalog symbol AC DC AC 80 40 Amps (class) DC BS88 ref. -- C1 BS88 ref. EF 250 -- FF 450, 500, 560, 630 (gG) 80 40 550 400 C2 FG 450, 500, 560, 630 (gG) 80 40 550 400 -- GF 710, 800 (gG) 80 40 550 250 C3 GG 710, 800 (gG) -- 500 250 -- 500 250 -- 500 -- 415 -- 415 -- B2 -- B3 B4 -- -- 415 Catalog no.* DC 250 500 Meets the requirements of BS88 Parts 1 and 2 and IEC 60269-1, CE B1 355, 400 (gG) 400M500 (gM) 80 1000, 1250 (gG) GH 710, 800, 1000, 1250 80 40 -- -- 415 550 550 550 250 -- -- -- D1 * To order, specify catalog symbol and amp rating, e.g., FG450. "M" indicates motor starter ratings. 550 125, 160, 200, 250, 315 (gG) 80 -- 415 * To order, specify catalog symbol and amp rating. E.g., BC40. "M" indicates motor starter ratings. Recommended fuse blocks Fuse catalog symbol Modular block catalog no.* AC BH-0111 AD BH-____ BC BH-0111 BD BH-____ CD BH-____ DD BH-____ ED BH-1131 * See data sheet no. 1200 (BH-0_) and 1201 (BH-1_) for details. Data sheets no. 4110 (AC), 4111 (AD), 4113 (BC), 4114 (BD), 4116 (CD), 4118 (DD), 4119 (ED) and 4121 (EFS) 5-8 Data sheet no. 4120 (EF), 4102 (FF), 4122 (FG), 4103 (GF), 4104 (GG) and 4108 (GH) BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries IEC and British Standard fuses -- 5 D16, D27, D33, D125 DIN Type D Diazed fuses NZ01, NZ02 DIN Type N Neozed fuses DIN style Type D ceramic body low voltage fuses. DIN style Type N ceramic body low voltage. Ratings Ratings ** Volts 500 Vac ** Volts 400 Vac ** Amps 2-100 A ** Amps 2-63 A ** IR 50 kA ** IR 50 kA Agency information ** Agency information IEC 60269 and DIN 49515, CE Catalog no. ** Amps "D" dimension Color code Fig. IEC 60269 and DIN 49515, CE Catalog no. Amps "D" dimension Color code 2D16 2 6 Pink 2NZ01 2 11 Pink 4D16 4 6 Brown 4NZ01 4 11 Brown 6D16 6 6 Green 6NZ01 6 11 Green 10D16 10 8 Red 10NZ01 10 11 Red 1 16D16 16 10 Grey 16NZ01 16 11 Grey 20D16 20 12 Blue 20NZ02 20 15 Blue 25D16 25 14 Yellow 25NZ02 25 15 Yellow 2D27 2 6 Pink 35NZ02 35 15 Black 4D27 4 6 Brown 50NZ02 50 15 White 6D27 6 6 Green 63NZ02 63 15 Copper 10D27 10 8 Red 16D27 16 10 Grey 20D27 20 12 Blue 25D27 25 14 Yellow 35D33 35 16 Black 50D33 50 18 White 63D33 63 20 Copper 80D125 80 5 Silver 100D125 100 7 Red Dimensions -- mm IEC and British Standard fuses 2 D 3 36 4 Additional 500 V quick acting fuses in body sizes D16, D27, D33 and D125 rated 2-100 A. Reference number suffixed "Q." E.g., 10D27Q. Gauge rings and keys can also be supplied. Dimensions -- mm 21.5 13.2 50 D Fig. 1 Fig. 2 Data sheet no. 4124 57 50 50 D 33.5 27.5 D Fig. 3 D Fig. 4 Data sheet no. 4124 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries 5-9 5 -- IEC and British Standard fuses ___NHG___B NH HRC fuses ___NHG___B NH HRC fuses DIN 000 to 4 Class: gG/gL DIN square bodied, dual indication industrial fuses with voltage conducting metal gripping lugs. They are made of a steatite insulator, corrosion-proof (aluminum) metal parts with full-contact and silver-plated copper blades. All NHG fuses feature a selectivity ratio: 1:1.6 up to 500 Vac. Ratings ** Volts ** 500 Vac ** 690 Vac ** Amps 2-1250 A ** IR 120 kA ** Frequency ** 45-62 Hz operating Agency information ** IEC 60269, VDE 0636, DIN 43620 ** CE (500 Vac only) Dimensions -- mm a4 a3 e3 d 2 min. c2 c1 e1 b e4 f e2 a2 a1 Fuse size 000 00 0 01 1 02 2 03 3 4 a1 79 79 125 135 135 150 150 150 150 200 a2 54 54 68 75 75 75 75 75 75 84 a3 45 45 62 62 62 62 62 62 62 80 a4 49 49 68 68 68 68 68 68 68 90 b 15 15 15 15 20 20 25 25 32 50 c1 35 35 35 40 40 48 48 60 60 85 c2 10 11 11 11 11 11 11 11 11 11 D 2 7.0 2.5 2.5 2.5 2.5 2.5 2.5 3.0 3 e1 41 48 48 48 53 53 61 61 75 120 Recommended fuse blocks Block catalog no. Fuse size SD00-D 000-00 SD1-D 1*, 1 SD2-D 02, 2, 03, 3 e2 21 30 30 30 52 52 60 60 70 87 e3 16 25 25 25 25 25 25 25 25 -- e4 6 6 6 6 6 6 6 6 6 8 f 8 15 15 15 15 15 15 15 18 30 500 Vac gG/gL dual indicator voltage conducting metal gripping lugs Amps 000 size 2 4 6 10 16 20 25 32 35 40 50 63 80 100 00 size 50 63 80 100 125 160 0 size 6 10 16 20 25 32 35 40 50 63 80 100 125 160 01 size 6 10 16 20 25 32 35 40 50 63 80 100 125 160 Catalog no. 2NHG000B 4NHG000B 6NHG000B 10NHG000B 16NHG000B 20NHG000B 25NHG000B 32NHG000B 35NHG000B 40NHG000B 50NHG000B 63NHG000B 80NHG000B 100NHG000B 50NHG00B 63NHG00B 80NHG00B 100NHG00B 125NHG00B 160NHG00B 6NHG0B 10NHG0B 16NHG0B 20NHG0B 25NHG0B 32NHG0B 35NHG0B 40NHG0B 50NHG0B 63NHG0B 80NHG0B 100NHG0B 125NHG0B 160NHG0B 6NHG01B 10NHG01B 16NHG01B 20NHG01B 25NHG01B 32NHG01B 35NHG01B 40NHG01B 50NHG01B 63NHG01B 80NHG01B 100NHG01B 125NHG01B 160NHG01B Amps 1 size 50 63 80 100 125 160 200 224 250 315 355 02 size 35 40 50 63 80 100 125 160 200 224 250 2 size 250 300 315 355 400 425 450 500 03 size 250 315 355 400 3 size 315 355 400 425 450 500 630 800 4 size* 500 630 800 1000 1250 Catalog no. 50NHG1B 63NHG1B 80NHG1B 100NHG1B 125NHG1B 160NHG1B 200NHG1B 224NHG1B 250NHG1B 315NHG1B 355NHG1B 35NHG02B 40NHG02B 50NHG02B 63NHG02B 80NHG02B 100NHG02B 125NHG02B 160NHG02B 200NHG02B 224NHG02B 250NHG02B 250NHG2B 300NHG2B 315NHG2B 355NHG2B 400NHG2B 425NHG2B 450NHG2B 500NHG2B 250NHG03B 315NHG03B 355NHG03B 400NHG03B 315NHG3B 355NHG3B 400NHG3B 425NHG3B 450NHG3B 500NHG3B 630NHG3B 800NHG3B 500NHG4G 630NHG4G 800NHG4G 1000NHG4G 1250NHG4G * Size 4 is a a single indicator fuse with slotted end blades. Data sheet no. 10164 (500 V), 720109 (690 V) 5-10 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries IEC and British Standard fuses -- 5 ___NHG___B NH HRC fuses JKS-700 fast-acting fuses 690 Vac gG/gL dual indicator voltage conducting metal gripping lugs Catalog no. 000 size Amps Catalog no. 2 size 2 2NHG000B-690 200 200NHG2B-690 4 4NHG000B-690 224 224NHG2B-690 6 6NHG000B-690 250 250NHG2B-690 10 10NHG000B-690 315 315NHG2B-690 16 16NHG000B-690 3 size 20 20NHG000B-690 250 250NHG3B-690 25 25NHG000B-690 315 315NHG3B-690 32 32NHG000B-690 355 355NHG3B-690 35 35NHG000B-690 400 400NHG3B-690 40 40NHG000B-690 425 425NHG3B-690 ** Volts 700 Vac (or less) 50 50NHG000B-690 500 500NHG3B-690 ** Amps 25-60 A 63 63NHG000B-690 4 size** ** IR 00 size 50 50NHG00B-690 63 63NHG00B-690 80 80NHG00B-690 100 100NHG00B-690 125 125NHG00B-690 160* 160NHG00B-690 Bussmann recommends the JM70100 modular fuse block and the JM70100-MW power distribution fuse block for the 30 amp case size JKS-700 fuses. See page 8-18 for details. Ratings 630 630NHG4B-690 ** Minimum 6In 800 800NHG4B-690 ** 200 kA RMS Sym. * 160 amps rated at 660 Vac. ** Size 4 is a single indicator fuse with slotted end blades. Operating class aR Agency information 1 size ** UL Recognized, 248-13 Semiconductor Fuses, File E56412 ** CSA Component Acceptance, C22.2 No 248.13 Semiconductor Fuses, Class 1422-30 50 50NHG1B-690 63 63NHG1B-690 Features 80 80NHG1B-690 ** 100 100NHG1B-690 125 125NHG1B-690 Current limitation for non-inductive circuits provides currentlimiting response to maximum ground fault and short-circuit conditions 160 160NHG1B-690 ** 200 kA interrupting rating provides protection at all circuit locations 200 200NHG1B-690 ** Economical circuit protection for high-fault current circuits 224 224NHG1B-690 Typical applications 250 250NHG1B-690 ** Power panelboards up to 700 Vac ** Machinery disconnects up to 700 Vac Catalog no. (amps) JKS-25-700 Data sheet no. 10164 (500 V), 720109 (690 V) JKS-30-700 JKS-35-700 JKS-60-700 Data sheet no. 1026 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries 5-11 IEC and British Standard fuses Amps The JKS-700 is a fast-acting, current-limiting fuse that is UL Recognized and has CSA Component Acceptance for applications up to 700 Vac. The JKS-700 is available in ratings up to 60 amps with the same dimensions as a standard Class J fuses; but its voltage rating places it outside the standard Class J fuse class. 5 -- IEC and British Standard fuses SD_ and TD_ NH fuse blocks Shroud kits NH fuse bases feature thermoplastic bodies, and DIN-Rail and screw mounting (size 4 is screw fix). They are available with a range of protection accessories for live parts for IP20 protection. Ratings ** Volts up to 690 Vac ** Amps up to 1250 A ** NH fuse sizes 000 to 4 Agency information ** IEC 60269, DIN 43620 Typical applications ** Protection of industrial circuits and electrical apparatus Catalog no. Fuse size Poles Amps Catalog no. Carton qty. SD00-D 3 TD00-D 1 SD1-D 3 TD1-D 1 SD2-D 3 TD2-D 1 SD3-D 3 TD3-D 1 SD4-S 3 Accepts fuse sizes DIN-Rail or screw mount 1 00 160 3 1 1 250 3 1 2 400 3 1 3 630 3 000 and 00 01 and 1 02 and 2 03 and 3 Screw mount only 4 1 1250 4 Catalog no. Fits fuse block TD00-IP20 TD00-D TD1-IP20 TD1-D TD2-IP20 TD2-D TD3-IP20 TD3-D SD12-SK SD1 and SD2 SD3-SK SD3 Terminal covers and separators (from shroud kits) Neutrals Terminal covers (1) Separator (3) Amps Cat. no. Carton qty. Cat. no. Carton qty. 160 CS00* 6 BC00* 2 0 160 CS0 6 BC0 2 1 250 CS1 6 BC1-2 2 2 400 CS2 6 BC1-2 2 3 630 CS3 6 BC3 2 NH size Amps Catalog no. Carton qty. NH size 1 250 SDL-1 3 00* 2 400 SDL-2 3 3 630 SDL-3 3 Fuse extraction handle Size Catalog no. Carton qty. C00-3 FEH 1 * For single pole only Phase barrier kits* Catalog no. Fits fuse block SD12-PB SD1 and SD2 SD3-PB SD3 * Kits include 2 phase barriers and 2 ganging links. Data sheet 720136 5-12 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries IEC and British Standard fuses -- 5 Class gG IEC 60269 industrial ferrule fuses 10 to 22mm diameter IEC Class gG fuses with optional indicators (10x38mm only) and strikers. See catalog numbers for availability and ratings. 10x38mm, Class gG, 500 and 400 Vac, 0.5 to 32 A Class gG, 400, 500 and 690 Vac, 2 to 125 A Catalog no. Standard W/ striker Vac C22G2 -- C22G4 C22G6 C22G8 C22G10 C22G12 C22G16 C22G20 C22G25 C22G32 C22G40 C22G50 C22G63 C22G80 C22G100 C22G125 C22G4S C22G6S C22G8S C22G10S C22G12S C22G16S 690 C22G20S C22G25S C22G32S C22G40S C22G50S C22G63S C22G80S 500 C22G100S C22G125S 400 Amps IR (kA) Holder/block 2 4 6 8 10 12 16 20 25 32 40 50 63 80 100 125 80 CH22 DIN-Rail*, JM70100 block 120 * Use striker version to actuate optional, external microswitch. Dimensions -- mm W/ indicator -- -- -- -- -- -- -- -- -- -- -- -- -- C10G321 C10G40I C10G50I Vac 500 400 400 500 500 400 Amps IR (kA) 0.5 1 2 4 6 8 10 12 120 16 20 25 32 32 32 40 50 Holder/block C D OA OE B CHM DIN-Rail*, BMM block Indicator/striker Catalog symbol OA B C D OE C10G 10 38 10 -- -- C14G 14.3 51 13 8 4 C22G 22 58 16 8 4 * Not recommended for use with indicator version. 14x51mm, Class gG, 400, 500 and 690 Vac, 1 to 50 A Catalog no. Standard C14G1 C14G2 -- C14G4 -- C14G6 -- C14G8 -- C14G10 -- C14G12 -- C14G16 -- C14G20 -- C14G25 -- C14G32 C14G40 C14G50 W/ striker -- -- C14G2S -- C14G4S -- C14G6S -- C14G8S -- C14G10S -- C14G12S -- C14G16S -- C14G20S -- C14G25S C14G32S C14G40S C14G50S Vac 690 500 690 500 690 500 690 500 690 500 690 500 690 500 690 500 690 500 400 Amps 1 2 4 6 8 10 12 16 20 25 32 40 50 IR ( kA) Holder 80 120 80 120 80 120 80 120 80 120 CH14 DIN-Rail** 80 120 80 120 80 120 80 120 ** Not recommended for use with indicator version, use striker version to actuate optional, external microswitch Data sheet no. 720115 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries 5-13 IEC and British Standard fuses Catalog no. Standard C10G0.5 C10G1 C10G2 C10G4 C10G6 C10G8 C10G10 C10G12 C10G16 C10G20 C10G25 C10G32 C10G32 -- -- -- .22x58mm, 5 -- IEC and British Standard fuses Class aM IEC 60269 industrial ferrule fuses 10 to 22mm diameter IEC Class aM fuses with optional indicators (22x58mm only) and strikers. See catalog numbers for availability and ratings. 10x38mm, Class aM, 500 and 400 Vac, 0.25 to 25 A Catalog no. Standard Vac C10M0.5 C10M1 C10M2 C10M4 C10M6 500 C10M8 C10M10 C10M12 C10M16 C10M20 400 C10M25 Amps IR (kA) 0.5 1 2 4 6 8 10 12 16 20 25 Holder/block W/ striker -- -- -- -- C14M2S -- C14M4S -- C14M6S -- C14M8S -- C14M10S -- C14M12S -- C14M16S -- C14M20S -- C14M25S C14M32S C14M40S C14M50S Vac 690 500 690 500 690 500 690 500 690 500 690 500 690 500 690 500 690 500 400 Catalog no. W/ Standard indicator C22M2 -- C22M4 -- C22M6 -- C22M8 -- C22M10 -- C22M12 -- C22M16 -- C22M20 -- C22M25 -- C22M32 -- C22M40 -- C22M50 -- C22M63 -- C22M80 -- C22M100 -- C22M125 C22M125I W/ striker -- -- -- -- -- C22M12S C22M16S C22M20S C22M25S C22M32S C22M40S C22M50S C22M63S C22M80S C22M100S C22M125S Vac Amps IR (kA) Holder/block 2 4 6 8 10 12 690 16 80 20 CH22 DIN-Rail*, JM70100 block 25 32 40 50 63 80 500 100 120 400 125 * Not recommended for use with indicator version, use striker version to actuate optional, external microswitch. Dimensions -- mm C D OA OE CHM Din-Rail, BMM block 14x51mm, Class aM, 400, 500 and 690 Vac, 0.25 to 50 A Catalog no. Standard C14M0.25 C14M0.5 C14M1 C14M2 -- C14M4 -- C14M6 -- C14M8 -- C14M10 -- C14M12 -- C14M16 -- C14M20 -- C14M25 -- C14M32 C14M40 C14M50 22x58mm, Class aM, 400, 500 and 690 Vac, 2 to 125 A B Indicator/striker Catalog symbol OA B C D OE C10M 10 38 10 -- -- C14M 14.3 51 13 8 4 C22M 22 58 16 8 4 Amps IR (kA) Holder 0.25 0.5 1 80 80 2 120 80 4 120 80 6 120 80 8 120 80 10 120 CH14 DIN-Rail** 80 12 120 80 16 120 80 20 120 80 25 32 40 50 120 ** Use striker version to actuate optional, external microswitch. Data sheet no. 720115 5-14 BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries IEC and British Standard fuses -- 5 HRC fuse holders CAMaster SAFEloc The Bussmann series CAMaster HRC fuse holder features a unique cam-action for easy fuse removal while allowing significantly improved contact pressure between fuse carrier and base contact that enhances electrical performance. A range of lockable safety carriers for the fuse holder (catalog reference LSC), are available. ** Volts 690 V The Bussmann series SAFEloc HRC fuse holders (for use with HRCI-CB fuses) provides a positive, stress-free fuse fitting and locks it in position to ensure safe insertion and withdrawal from the base. Base contacts are fully shrouded to help protect against electric shock. Shrouds utilize simple slide/snap action allowing access to the contact terminal screws. It can be mounted on a 35mm DIN-Rail or panel-mounted with a single screw. ** Amps up to 100 A Ratings Agency information ** CSA C22.2 No. 39; IEC 269 and BS88, CE Catalog no. Amps CM20CF 30 CM30CF 30 CM60CF 60 CM100CF 100 Details for Fuses accepted HRCI-CA applications HRCII applications _CIF21 _H07C _K07C _K07CR Accessories ** Volts 600 V ** Amps 30-60 A Agency information ** Designed to accommodate the compact range of offset blade fuse to CSA C22.2 No. 106, HRCI-CB, CE Catalog no.* Amps 20BS 30 32BS 30 60/100BS 60/100 GLP All 20LSC 30 32LSCC 30 63/100LSC 60/100 Description CAMaster accepted CM20CF Back stud CM30CF CM60/100CF Ganging link kit 3-Pole CM20CF Security carrier with clip Connection C30F C30BS Catalog no. Amps Front 30 Back C30FBS _CIF06 Front-back C60F C60BS Fuses accepted Front 60 Back C60FBS EK-(amp) Front-back * For use with HRCI-CB fuses. Bussmann series Red Spot fuse holders CM30CF CM60/100CF These versatile CSA Certified and IP20 finger-safe fuse holders for BS88 HRC industrial fuses are available in ratings from 20 to 400 amps. Padlock inserts, warning carriers and fuse adapter accessories enhance safety and application flexibility. See data sheet no. 10083 for details. BUSSMANN SERIES FULL LINE CATALOG 1007 -- JUNE 2017 Eaton.com/bussmannseries 5-15 IEC and British Standard fuses Ratings BUSSMANN SERIES Enhanced safety. Improved system reliability. Simplified inventory. It's easier than ever to improve your circuit protection while efficiently reducing your fuse inventory. Leveraging BussmannTM series ultimate protection fuses, our Low-PeakTM Upgrade program couples the industry's most advanced circuit protection with our extensive knowledge to deliver enganced safety, improved system reliability and simplified inventory. In just three simple steps, you'll save time and increase productivity. All by using Bussmann series Low-Peak fuses. Three steps to ultimate protection: 1 Audit 2 Analyze 3 Implement Visit Eaton.com/bussmannseries to learn more. Follow us on social media to get the latest product and support information.