IEC and British Standard fuses — 5
IEC and British
Standard fuses
Contents
Description
Section
page
Fuses
CSA Type P and D fuses (CDN, CDS and PON) 2
HRC Form II Class C fuses (CGL) 3
HRCI industrial ceramic body fuses
HRCI-CA (CIF21) 4
HRCI-CB (CIF06)
HRCI-Misc. Type K (CIH, CIK and CIL) 5
HRC Form II current-limiting fuses (H07C, K07C, L14C,
M14C, L09C, M09C, P09C, P11C, R11C) 6
BS88 Part 1 fuses
SSD, NSD, ESD 7
STD, NITD, AAO, BAO, OSD, CEO, DEO
BS88
AC, AD, BC, BD, CD, DD, ED, EFS 8
EF, FF, FG, GF, GG, GH
DIN Type D Diazed (D16, D27, D33, D125) 9
DIN Type N Neozed (NZ01, NZ02)
NH HRC fuses (NHG) 10-11
JKS-700 fast-acting, current limiting UL Recognized and CSA
Component Acceptance 700 Vac fuses up to 60 amps 11
NH fuse blocks and accessories (SD, TD) 12
Fuses continued
IEC 60269 industrial fuses with and without indicator/striker
Class gG ferrule (C10G, C14G, C22G) 13
Class aM ferrule (C10M, C14M, C22M) 14
HRC fuse holders
CAMaster
15SAFEloc
Red Spot
Bussmann series IEC
cylindrical fuses
Complete portfolio of 8-22
mm diameter Class aM and
Class gG cylindrical fuses for
industrial applications
5-1
BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
5 — IEC and British Standard fuses
CDN, CDS and PON CSA Type P and D fuses
CSA time-delay Type D and P fuses.
Ratings
Volts
250 Vac (CDN and PON)
600 Vac (CDS)
Amps 10-600 A
IR 10 kA minimum
Agency information
CSA Certified to C22.2 No. 59.1, CE
Features
Economical fuse in a variety of ratings for applications not
requiring time-delay
Typical applications
Lighting, heating and other circuits not subject to temporary
surges and where available short-circuit current are relatively low
Catalog no.*
Catalog symbol Volts Available amp ratings
Time-Delay CSA Type "D" fuses
CDN** 250 Vac
10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60,
70, 80, 90, 100, 110, 125, 150, 175, 200,
225, 250, 300, 350, 400, 450, 500, 600
CDS600 Vac
10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60,
70, 80, 90, 100, 110, 125, 150,175, 200,
225, 250, 300, 350, 400, 450, 500, 600
One-time CSA Type "P" fuses
PON 250 Vac 15, 20, 25, 30, 35, 40, 45, 50, 60
* To order, specify catalog symbol and amp rating, e.g., CDN30, CDS110 or
PON40.
** Below 10 amps, use FRN-R.
Below 10 amps, use FRS-R.
Dimensions — in (mm)
Amps A B C D E F
CDN/PON 250 Vac
Up to 30 2.0 (51) 0.6 (14)
35-60 3.0 (76) 0.8 (21)
70-100 5.9 (149) 1.0 (25) 0.1 (3) 0.8 (19)
110-200 7.3 (185) 1.4 (35) 4.1 (105) 0.2 (5) 1.1 (29)
225-400 8.6 (219) 1.9 (48) 4.6 (118) 0.3 (6) 1.6 (41)
450-600 10.4 (264) 2.3 (57) 5.2 (132) 0.3 (6) 2 (51)
CDS 600 Vac
Up to 30 5.0 (127) 0.8 (21)
35-60 5.5 (140) 1.1 (27)
70-100 7.9 (200) 1.0 (25) 0.1 (3) 0.8 (19)
110-200 9.6 (245) 1.4 (35) 6.1 (116) 0.2 (5) 1.1 (29)
225-400 11.6 (295) 1.9 (48) 7.1 (118) 0.3 (6) 1.6 (41)
450-600 13.4 (340) 2.3 (57) 8.2 (208) 0.3 (6) 2 (51)
Recommended fuse blocks
Catalog no.* Volts
Fuse amps 250 600
Up to 30 HM25030-(poles) HM60030-(poles)
35-60 HM25060-(poles) HM60060-(poles)
70-100 HM25100-(poles) HM60100-(poles)
110-200 HM25200-(poles) HM60200-(poles)
225-400 HM25400-(poles) HM60400-(poles)
450-600 HM25600-(poles) HM60600-(poles)
* To order, specify 1, 2 or 3 poles, e.g., HM25030-2_. See data sheets 10289
(30-60 A) and 3192 (70-600 A) for available terminals.
E
B
F
A
DC
70 to 600 A
AB
Up to 60 A
Data sheet no. 4126
5-2 BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
IEC and British Standard fuses — 5
IEC and British
Standard fuses
CGL HRC Form II Class C fuses
Current-limiting HRCII-C fuses designed to withstand inrush currents
on typical motor start-ups while offering high current limitation in the
short-circuit region. See drawings for dimensions.
Ratings
Volts
600 Vac
250 Vdc (1-30 A)
Amps 1-600 A
IR
200 kA
40 kA DC
Agency information
CSA Certified, C22.2 No. 106, Class 1422,File 53787, CE
Catalog no. (amps)
CGL-1 CGL-25 CGL-80 CGL-225
CGL-2 CGL-30 CGL-90 CGL-250
CGL-3 CGL-35 CGL-100 CGL-300
CGL-4 CGL-40 CGL-110 CGL-350
CGL-6 CGL-45 CGL-125 CGL-400
CGL-10 CGL-50 CGL-150 CGL-450
CGL-15 CGL-60 CGL-175 CGL-500
CGL-20 CGL-70 CGL-200 CGL-600
Features
Close sizing to loads allows using smaller and less costly switches
Provides a higher degree of short-circuit protection
Helps protect motors against burnout from overloads
Typical applications
For use in circuits subject to surge currents such as those caused
by motors, transformers and other inductive loads
Available Red Spot fuse holders
Fuse amps Catalog symbol*
Up to 32 RS32_
35-60 RS63_
70-100 RS100_
110-200 RS200_
225-400 RS400_
* See Red Spot data sheet no. 10083 for terminal options.
Data sheet no. 4125
2.0
(50.8)
2.80
(71.04)
3.5
(88.9)
0.94
(23.81)
0.06
(1.59)
2.0
(50.8)
2.80
(71.04)
3.31
(84.14)
0.81
(20.64)
0.22
(5.56)
0.22
(5.56)
0.34
(8.73)
CGL 1-30
CGL 35-60
0.50
(12.7)
0.81
(20.64)
0.22
(5.56)
0.22
(5.56)
1.06
(26.92)
0.06
(1.59)
CGL 70-100
0.75
(19.05)
1.34
(34.04)
0.343
(8.71)
0.343
(8.71)
2.39
(60.72)
3.64
(92.47)
4.31
(109.54)
1.375
(34.93)
0.09
(2.29)
CGL 110-200
0.75
(19.05)
0.343
(8.71)
0.343
(8.71)
3.00
(76.2)
4.30
(109.22)
5.31
(134.87)
1.50
(38.1)
0.125
(3.18)
CGL 225-400
1.0
(25.4)
0.38
(9.53)
3.0
(76.2)
5.25
(133.35)
8.19
(207.96)
2.38
(60.33)
0.19
(4.76)
1.0
(25.4)
CGL 450-600
0.41
(10.32)
3.00
(76.2)
1.0
(25.4)
1.0
(25.4)
0.375
(9.53)
3.0
(76.2)
5.25
(133.35)
8.19
(207.96)
0.60
(15.24)
Dimensions — in (mm)
5-3
BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
5 — IEC and British Standard fuses
CIF06 HRCI-CB industrial ceramic body fuses
A miniature offset clip-in blade, ceramic body industrial fuse that
provides both short-circuit and overload protection and the CIF06 fits
the 30 A SAFEloc fuse holder (data sheet number 4133).
Ratings
Volts
600 Vac
250 Vdc
Amps 1-30 A
IR 200 kA RMS Sym.
Agency information
CSA C22.2 No. 106-M92 (3-30 A only), CE
Catalog no. Amps Catalog no. Amps
1CIF06 1 15CIF06 15
3CIF06 3 20CIF06 20
6CIF06 6 25CIF06 25
10CIF06 10 30CIF06 30
Features
Close sizing to loads allows using smaller and less costly switches
Provides a higher degree of short-circuit protection
Helps protect motors against burnout from overloads
Typical applications
For use in circuits subject to surge currents such as those caused
by motors, transformers and other inductive loads
Recommended fuse holders
Amps Description Catalog no.*
Up to 30 SAFEloc C30(terminal option)
* See data sheet no. 4133 for SAFEloc details.
Dimensions — in (mm)
Data sheet no. 4128
2.38 (60)
1.44 (36)
0.54 (14)
0.14 (4)
0.5 (13)
0.03 (4)
CIF21 HRCI-CA industrial ceramic body fuses
The HRCI-CA bolt-on, ceramic body fuse provides both overload
and short-circuit protection to HRCI requirements. Offset blades for
bolt-on mounting CIF21 fuse fits the Bussmann series Red Spot
fuse holder (data sheet 10083) and CAMaster fuse holder (data
sheet number 4132).
Ratings
Volts
600 Vac
250 Vdc
Amps 1-30 A
IR 200 kA RMS Sym.
Agency information
CSA C22.2, No. 106-M92, CE
Catalog no. Amps Catalog no. Amps
1CIF21 1 15CIF21 15
3CIF21 3 20CIF21 20
6CIF21 6 25CIF21 25
10CIF21 10 30CIF21 30
Features
Close sizing to loads allows using smaller and less costly switches
Provides a higher degree of short-circuit protection
Helps protect motors against burnout from overloads
Typical applications
For use in circuits subject to surge currents such as those caused
by motors, transformers and other inductive loads
Recommended fuse holders
Amps Description Catalog no.*
Up to 20 Red Spot RS20_(terminal option)
Up to 30 CAMaster CM20CF
* See data sheet no. 10083 (Red Spot) and 4132 (CAMaster) for details.
Dimensions — in (mm)
Data sheet no. 4127
2.15 (55)
1.44 (36)
1.75 (45)
0.19 (5)
0.54 (14)
0.44 (11)
0.03 (1)
5-4 BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
IEC and British Standard fuses — 5
IEC and British
Standard fuses
CIH, CIK and CIL HRCI — Misc. Type K fuses
Misc. Type K HRCI bolt-on, ceramic body fuses provide both overload
and short-circuit protection, featuring offset blades for bolt down
mounting.
Ratings
Volts 600 V
Amps 1-100 A
IR 200 kA@600 V
Agency information
CSA C22.2 No. 106-M92, CE
Catalog no. (amp)CIH, CIK, CIL
1CIH07 15CIH07 35CIK07 80CIL14
3CIH07 20CIH07 40CIK07 90CIL14
6CIH07 25CIH07 50CIK07 100CIL14
10CIH07 30CIH07 60CIK07
Dimensions — in (mm)
The CIL14 has a rejection hole, not a slot as shown above.
Amps A B C D E F G H J K L
Up to
30
2.25
(57)
0.94
(24)
3.38
(86)
0.38
(10)
0.04
(1)
2.88
(73)
0.21
(5)
0.31
(8)
1
(25)
0.10
(3)
2.38
(60)
35- 60 2.28
(58)
1.06
(27)
3.56
(91)
0.5
(13)
0.05
(1)
2.88
(73)
0.21
(5)
0.41
(11)
1.09
(28)
0.13
(3)
2.38
(61)
80-
100
2.75
(70)
1.44
(37)
4.38
(111 )
0.75
(19)
0.09
(3)
3.69
(94)
0.34
(9)
0.41
(11)
1.5
(39) 2.91
(74)
Recommended fuse holders
Amps Red Spot* CAMaster*
Up to 30 RS32_ CM30CF
35-60 RS63_ CM60CF
80-100 RS100_
* See data sheet no. 10083 (Red Spot) and 4132 (CAMaster) for details.
E
G
G
H
D
K
F
A
L
C
J
B
Data sheet no. 4130
5-5
BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
5 — IEC and British Standard fuses
HRC Form II current-limiting fuses
HRC Form II bolt-on, ceramic body current-limiting fuses.
Ratings
Volts
600 Vac (or less)
250 Vdc
Amps 2-600 A
IR 200 kA RMS Sym.
Agency information
CSA C22.2 No. 106-M92, BS88:2, IEC 60269:2, CE
(amps) catalog no.
H07C offset blades
2H07C 6H07C 15H07C 25H07C
4H07C 10H07C 20H07C 30H07C
K07C offset blades
40K07C 60K07C 100K07CR
50K07C 80K07CR
L14C offset blades
80L14C 100L14C
M14C offset blades
125M14C* 150M14C* 200M14C*
L09C center blades
80L09C* 100L09C*
M09C center blades
125M09C 150M09C 200M09C
P09C center blades
250P09C* 300P09C* 350P09C* 400P09C*
P11C center blades
250P11C 300P11C 350P11C 400P11C
R11C center blades
450R11C 500R11C 600R11C
* Not suitable for installation in Red Spot fuse holders.
Typical applications
Used to protect motor control circuits, together with contactors
and overload protection relays to provide Type 2 coordination per
IEC 60947-4.
Recommended fuse holders: Red Spot up to 400 amps (data sheet
no.10083) and CAMaster up to 100 amps (data sheet no. 4132).
E
D
G
F
A
H
C
J
B
D
G
C
A
F
B
E
H
E
D
G
F
A
H
C
J
B
FB
E
G
C
A
K
D
K
H
H07C offset blades
K07C, K07CR, L14C, M14C offset blades
L09C, M09C, P09C center blades
P11C, R11C center blades
Data sheet no. 4131
Dimensions — in (mm)
Catalog
symbol/
style A B C D E F G H J K
CSA
category
H07C offset blades
2-30 1.38
(35)
0.56
(14)
3.38
(85)
0.38
(9)
0.06
(1)
2.88
(73)
0.22
(6)
0.31
(8)
0.56
(14) HRCII-C
K07C offset blades
40-60 2.19
(56)
0.88
(22)
3.44
(87)
0.5
(13)
0.06
(1)
2.88
(73)
0.22
(6)
0.31
(8)
0.88
(22) HRCII-C
80-100 2.19
(56)
0.88
(22)
3.75
(95)
0.5
(13)
0.06
(1)
2.88
(73)
0.22
(6)
0.31
(8)
0.88
(22) HRCII-
MISC
L14C offset blades
80-100 2.38
(60)
0.88
(21)
4.38
(111 )
0.56
(14)
0.13
(3)
3.69
(94)
0.34
(9)
0.44
(11)
1
(25) HRCII-C
M14C offset blades
125-200 2.56
(65)
1.5
(38)
4.38
(111 )
0.75
(19)
0.09
(2)
3.69
(94)
0.34
(9)
0.44
(11) HRCII-
MISC
L09C center blades
80-100 2.38
(60)
0.88
(21)
5
(127)
0.56
(14)
0.13
(3)
4.38
(111 )
0.34
(9)
0.44
(11) HRCII-
MISC
M09C center blades
125-200 2.56
(65)
1.5
(38)
5.38
(136)
0.75
(19)
0.13
(3)
4.38
(111 )
0.34
(9)
0.56
(14) HRCII-C
P09C center blades
250-400 3.06
(178)
2.31
(59)
5.38
(136)
1
(25)
0.19
(5)
4.38
(111 )
0.34
(9)
0.5
(13) HRCII-
MISC
P11C center blades
250-400 3.06
(178)
2.31
(59)
8.25
(210)
1
(25)
0.19
(5)
5.25
(133)
0.41
(10)
0.63
(16) 1
(25) HRCII-C
R11C center blades
450-600 3.19
(81)
2.88
(73)
8.25
(210)
1
(25)
0.25
(6)
5.25
(133)
0.41
(10)
0.63
(16) 1
(25) HRCII-C
5-6 BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
IEC and British Standard fuses — 5
IEC and British
Standard fuses
SSD, NSD, ESD BS88 Part 1 fuses
The NSD and ESD are low voltage offset blade, ceramic body fuses
complying with general purpose gG characteristics.
Ratings
Volts 240-550 Vac
Amps
2-63 A
20M25 to 63M100 motor starter ratings
IR
33 kA (SSD)
80 kA (NSD, ESD)
Agency information
Meets the requirements of BS88 Part 1 and IEC 60269-1, CE
Catalog no.*
Catalog
symbol Amps (class)
Max
Vac
BS88
ref.
SSD 2, 4, 6, 10, 16, 20, 25, 32 (gG) 240 E1
NSD
2, 4, 6, 10, 16, 20, 25, 32 (gG) 550
F1
20M25, 20M32, 20M36, 32M36, 32M40,
32M50, 32M63 (gM) 415
ESD
2, 4, 6, 10, 16, 20, 25, 32 (gG) 550
F240, 50, 63 (gG) 415
63M80, 63M100 (gM)
* To order, specify catalog symbol and amp rating, e.g., SSD20.
"M" indicates motor starter ratings.
Recommended fuse holders
Fuse symbol Catalog no.
NSD 32NNSF
ESD 63ENSF
STD, NITD, AAO, BAO, OSD, CEO, DEO BS88 Part 1
fuses
The STD to DEO type ceramic body, offset bolt-on blade low voltage
fuses complying with general purpose gG characteristics.
Ratings
Volts 240-550 Vac
Amps
2-200 A
20M25 to 200M315 motor starter ratings
IR
33 kA (STD)
80 kA (NITD, AAO, BAO, CEO, DEO, OSD)
Agency information
Meets the requirements of BS88 Part 1 and IEC 60269-1, CE
Catalog no.*
Catalog
symbol Amps (class)
Max
Vac
BS88
ref.
STD 2, 4, 6, 10, 16, 20, 25, 32 (gG) 240
NITD
2, 4, 6, 10, 16, 20, 25, 32 (gG) 550 20M25, 20M32 (gM)
32M40, 32M50, 32M63 (gM) 415
AAO2, 4, 6, 10, 16, 20, 25, 32, (gG) 550 A2
32M40, 32M50, 32M63 (gM) 500
BAO40, 50, 63 (gG) 500 A3
63M80, 63M100 (gM)
CEO32, 40, 50, 63, 80, 100 (gG) 550 A4
100M125, 100M160, 100M200 (gM) 415
DEO125, 160, 200 (gG) 415
200M315 (gM)
OSD80, 100 (gG) 500
100M125, 100M160 (gM) 415
* To order, specify basic catalog symbol and amp rating. E.g., BAO16.
"M" indicates motor starter ratings.
Typical applications
The STD type are used in 240 V street lighting cut-outs
NITD to DEO types used for industrial and general purpose
applications
Recommended fuse blocks and holders
Fuse catalog symbol Block/holder catalog no.*
NITD CM32FC, RS20_
AAO CM32F, RS32_
BAO CM63F, RS63_
OSD CM100F, RS100_
CEO BH-0111
* See data sheet no. 4132 (CM_), 10083 (RS_) and 1200 (BH-_).
Data sheet no. 4105 (SSD), 4100 (NSD) and 4101 (ESD)
Data sheet no. 4123 (STD), 4106 (NITD), 4109 (AAO),
4112 (BAO), 4107 (OSD), 4115 (CEO) and 4117 (DEO)
5-7
BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
5 — IEC and British Standard fuses
AC, AD, BC, BD, CD, DD, ED, EFS BS88 fuses
Ceramic body, center blade two-hole bolt-on low voltage fuses that
comply with general purpose gG characteristics and available up to
400 amps with two hole mount and up to 1250 amps with four hole
mount.
Ratings
Volts
415/550 Vac
250 Vdc
Amps
2-400 A
63M80 to 400M500 motor starter ratings
IR see catalog numbers table
Agency information
Meets the requirements of BS88 Parts 1 and 2 and IEC 60269-1,
CE
Catalog no.* IR ( kA) Max volts
BS88
ref.
Catalog
symbol Amps (class) AC DC AC DC
AC 2, 4, 6, 10, 16, 20 (gG) 80 40 550 250
25, 32 (gG) 500
AD 2, 4, 6, 10, 16, 20 (gG) 80 40 550 250
25, 32 (gG) 500
BC40, 50, 63 (gG) 80 40 500 250
63M80, 63M100 (gM)
BD 40, 50, 63 (gG) 80 40 500 250
CD
CD80, CD100 (gG)
80
500
B1
100M125, 100M160,
100M200 (gM) 415
DD125, 160, 200 (gG) 80 415 B2
200M250, 200M315 (gM)
ED
250, 315, 355, 400 (gG)
80 415 B3
B4
315M400 (gM)
400M500 (gM) 550
EFS 125, 160, 200, 250, 315
(gG) 80 415
* To order, specify catalog symbol and amp rating. E.g., BC40.
"M" indicates motor starter ratings.
Recommended fuse blocks
Fuse catalog symbol Modular block catalog no.*
AC BH-0111
AD BH-____
BC BH-0111
BD BH-____
CD BH-____
DD BH-____
ED BH-1131
* See data sheet no. 1200 (BH-0_) and 1201 (BH-1_) for details.
EF, FF, FG, GF, GG, GH BS88 fuses
Ceramic body, center blade four-hole bolt-on low voltage fuses
complying with general purpose gG characteristics and available up
to 400 amps with two hole mount and up to 1250 amps with four
hole mount.
Ratings (see catalog numbers table)
Volts
415/690 Vac
250/400 Vdc
Amps 355-1250 A
IR see catalog numbers table
Agency information
Meets the requirements of BS88 Parts 1 and 2 and IEC 60269-1,
CE
Catalog no.* IR ( kA) Max volts
BS88
ref.
Catalog
symbol Amps (class) AC DC AC DC
EF355, 400 (gG) 80 40 415 C1
400M500 (gM) 550
FF 450, 500, 560, 630 (gG) 80 40 550 400 C2
FG 450, 500, 560, 630 (gG) 80 40 550 400
GF 710, 800 (gG) 80 40 550 250 C3
GG 710, 800 (gG) 80 40 550 250
1000, 1250 (gG)
GH 710, 800, 1000, 1250 80 550 D1
* To order, specify catalog symbol and amp rating, e.g., FG450.
"M" indicates motor starter ratings.
Data sheets no. 4110 (AC), 4111 (AD), 4113 (BC), 4114 (BD),
4116 (CD), 4118 (DD), 4119 (ED) and 4121 (EFS)
Data sheet no. 4120 (EF), 4102 (FF), 4122 (FG), 4103 (GF),
4104 (GG) and 4108 (GH)
5-8 BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
IEC and British Standard fuses — 5
IEC and British
Standard fuses
D16, D27, D33, D125 DIN Type D Diazed fuses
DIN style Type D ceramic body low voltage fuses.
Ratings
Volts 500 Vac
Amps 2-100 A
IR 50 kA
Agency information
IEC 60269 and DIN 49515, CE
Catalog no. Amps "D" dimension Color code Fig.
2D16 2 6 Pink
1
4D16 4 6 Brown
6D16 6 6 Green
10D16 10 8Red
16D16 16 10 Grey
20D16 20 12 Blue
25D16 25 14 Yellow
2D27 2 6 Pink
2
4D27 4 6 Brown
6D27 6 6 Green
10D27 10 8Red
16D27 16 10 Grey
20D27 20 12 Blue
25D27 25 14 Yellow
35D33 35 16 Black
350D33 50 18 White
63D33 63 20 Copper
80D125 80 5 Silver 4
100D125 100 7Red
Additional 500 V quick acting fuses in body sizes D16, D27, D33 and
D125 rated 2-100 A. Reference number suffixed "Q." E.g., 10D27Q.
Gauge rings and keys can also be supplied.
Dimensions — mm
NZ01, NZ02 DIN Type N Neozed fuses
DIN style Type N ceramic body low voltage.
Ratings
Volts 400 Vac
Amps 2-63 A
IR 50 kA
Agency information
IEC 60269 and DIN 49515, CE
Catalog no. Amps "D" dimension Color code
2NZ01 2 11 Pink
4NZ01 4 11 Brown
6NZ01 6 11 Green
10NZ01 10 11 Red
16NZ01 16 11 Grey
20NZ02 20 15 Blue
25NZ02 25 15 Yellow
35NZ02 35 15 Black
50NZ02 50 15 White
63NZ02 63 15 Copper
Dimensions — mm
Data sheet no. 4124 Data sheet no. 4124
D
36
13.2 21.5 27.5 33.5
57
50
50
50
D
D
D
D
Fig. 1 Fig. 4
Fig. 3Fig. 2
5-9
BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
5 — IEC and British Standard fuses
___NHG___B NH HRC fuses
500 Vac gG/gL dual indicator voltage conducting metal
gripping lugs
___NHG___B NH HRC fuses
DIN 000 to 4 Class: gG/gL DIN square bodied, dual indication
industrial fuses with voltage conducting metal gripping lugs. They
are made of a steatite insulator, corrosion-proof (aluminum) metal
parts with full-contact and silver-plated copper blades. All NHG fuses
feature a selectivity ratio: 1:1.6 up to 500 Vac.
Ratings
Volts
500 Vac
690 Vac
Amps 2-1250 A
IR 120 kA
Frequency
45-62 Hz operating
Agency information
IEC 60269, VDE 0636, DIN 43620
CE (500 Vac only)
Dimensions — mm
Fuse
size a1a2a3a4b c1c2D e1e2e3e4f
000 79 54 45 49 15 35 10 2 41 21 16 6 8
00 79 54 45 49 15 35 11 7. 0 48 30 25 6 15
0125 68 62 68 15 35 11 2.5 48 30 25 6 15
01 135 75 62 68 15 40 11 2.5 48 30 25 6 15
1135 75 62 68 20 40 11 2.5 53 52 25 6 15
02 150 75 62 68 20 48 11 2.5 53 52 25 6 15
2150 75 62 68 25 48 11 2.5 61 60 25 6 15
03 150 75 62 68 25 60 11 2.5 61 60 25 6 15
3150 75 62 68 32 60 11 3.0 75 70 25 6 18
4 200 84 80 90 50 85 11 3120 87 8 30
Recommended fuse blocks
Block catalog no. Fuse size
SD00-D 000-00
SD1-D 1*, 1
SD2-D 02, 2, 03, 3
a4
a3
a2
a1
c2
e3
e2
e4
e1
2 min.
c1
b
f
d
Data sheet no. 10164 (500 V), 720109 (690 V)
Amps Catalog no.
000 size
2 2NHG000B
4 4NHG000B
6 6NHG000B
10 10NHG000B
16 16NHG000B
20 20NHG000B
25 25NHG000B
32 32NHG000B
35 35NHG000B
40 40NHG000B
50 50NHG000B
63 63NHG000B
80 80NHG000B
100 100NHG000B
00 size
50 50NHG00B
63 63NHG00B
80 80NHG00B
100 100NHG00B
125 125NHG00B
160 160NHG00B
0 size
6 6NHG0B
10 10NHG0B
16 16NHG0B
20 20NHG0B
25 25NHG0B
32 32NHG0B
35 35NHG0B
40 40NHG0B
50 50NHG0B
63 63NHG0B
80 80NHG0B
100 100NHG0B
125 125NHG0B
160 160NHG0B
01 size
6 6NHG01B
10 10NHG01B
16 16NHG01B
20 20NHG01B
25 25NHG01B
32 32NHG01B
35 35NHG01B
40 40NHG01B
50 50NHG01B
63 63NHG01B
80 80NHG01B
100 100NHG01B
125 125NHG01B
160 160NHG01B
Amps Catalog no.
1 size
50 50NHG1B
63 63NHG1B
80 80NHG1B
100 100NHG1B
125 125NHG1B
160 160NHG1B
200 200NHG1B
224 224NHG1B
250 250NHG1B
315 315NHG1B
355 355NHG1B
02 size
35 35NHG02B
40 40NHG02B
50 50NHG02B
63 63NHG02B
80 80NHG02B
100 100NHG02B
125 125NHG02B
160 160NHG02B
200 200NHG02B
224 224NHG02B
250 250NHG02B
2 size
250 250NHG2B
300 300NHG2B
315 315NHG2B
355 355NHG2B
400 400NHG2B
425 425NHG2B
450 450NHG2B
500 500NHG2B
03 size
250 250NHG03B
315 315NHG03B
355 355NHG03B
400 400NHG03B
3 size
315 315NHG3B
355 355NHG3B
400 400NHG3B
425 425NHG3B
450 450NHG3B
500 500NHG3B
630 630NHG3B
800 800NHG3B
4 size*
500 500NHG4G
630 630NHG4G
800 800NHG4G
1000 1000NHG4G
1250 1250NHG4G
* Size 4 is a a single indicator fuse
with slotted end blades.
5-10 BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
IEC and British Standard fuses — 5
IEC and British
Standard fuses
___NHG___B NH HRC fuses
690 Vac gG/gL dual indicator voltage conducting metal
gripping lugs
Amps Catalog no.
000 size
2 2NHG000B-690
4 4NHG000B-690
6 6NHG000B-690
10 10NHG000B-690
16 16NHG000B-690
20 20NHG000B-690
25 25NHG000B-690
32 32NHG000B-690
35 35NHG000B-690
40 40NHG000B-690
50 50NHG000B-690
63 63NHG000B-690
00 size
50 50NHG00B-690
63 63NHG00B-690
80 80NHG00B-690
100 100NHG00B-690
125 125NHG00B-690
160* 160NHG00B-690
1 size
50 50NHG1B-690
63 63NHG1B-690
80 80NHG1B-690
100 100NHG1B-690
125 125NHG1B-690
160 160NHG1B-690
200 200NHG1B-690
224 224NHG1B-690
250 250NHG1B-690
Amps Catalog no.
2 size
200 200NHG2B-690
224 224NHG2B-690
250 250NHG2B-690
315 315NHG2B-690
3 size
250 250NHG3B-690
315 315NHG3B-690
355 355NHG3B-690
400 400NHG3B-690
425 425NHG3B-690
500 500NHG3B-690
4 size**
630 630NHG4B-690
800 800NHG4B-690
* 160 amps rated at 660 Vac.
** Size 4 is a single indicator fuse with
slotted end blades.
Data sheet no. 10164 (500 V), 720109 (690 V)
JKS-700 fast-acting fuses
The JKS-700 is a fast-acting,
current-limiting fuse that is
UL Recognized and has CSA
Component Acceptance for
applications up to 700 Vac. The
JKS-700 is available in ratings
up to 60 amps with the same
dimensions as a standard Class J
fuses; but its voltage rating places
it outside the standard Class J fuse
class.
Bussmann recommends the JM70100 modular fuse block and the
JM70100-MW power distribution fuse block for the 30 amp case size
JKS-700 fuses. See page 8-18 for details.
Ratings
Volts 700 Vac (or less)
Amps 25-60 A
IR
Minimum 6In
200 kA RMS Sym.
Operating class aR
Agency information
UL Recognized, 248-13 Semiconductor Fuses, File E56412
CSA Component Acceptance, C22.2 No 248.13 Semiconductor
Fuses, Class 1422-30
Features
Current limitation for non-inductive circuits provides current-
limiting response to maximum ground fault and short-circuit
conditions
200 kA interrupting rating provides protection at all circuit locations
Economical circuit protection for high-fault current circuits
Typical applications
Power panelboards up to 700 Vac
Machinery disconnects up to 700 Vac
Catalog no. (amps)
JKS-25-700 JKS-30-700 JKS-35-700 JKS-60-700
Data sheet no. 1026
5-11
BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
5 — IEC and British Standard fuses
SD_ and TD_ NH fuse blocks
NH fuse bases feature thermoplastic bodies, and DIN-Rail and screw
mounting (size 4 is screw fix). They are available with a range of
protection accessories for live parts for IP20 protection.
Ratings
Volts up to 690 Vac
Amps up to 1250 A
NH fuse sizes 000 to 4
Agency information
IEC 60269, DIN 43620
Typical applications
Protection of industrial circuits and electrical apparatus
Catalog no.
Fuse
size Poles Amps Catalog no.
Carton
qty.
Accepts fuse
sizes
DIN-Rail or screw mount
00 1160 SD00-D 3 000 and 00
3 TD00-D 1
11250 SD1-D 3 01 and 1
3 TD1-D 1
21400 SD2-D 3 02 and 2
3 TD2-D 1
31630 SD3-D 3 03 and 3
3 TD3-D 1
Screw mount only
4 1 1250 SD4-S 3 4
Neutrals
NH size Amps Catalog no. Carton qty.
1 250 SDL-1 3
2 400 SDL-2 3
3 630 SDL-3 3
Fuse extraction handle
Size Catalog no. Carton qty.
C00-3 FEH 1
Data sheet 720136
Shroud kits
Catalog no. Fits fuse block
TD00-IP20 TD00-D
TD1-IP20 TD1-D
TD2-IP20 TD2-D
TD3-IP20 TD3-D
SD12-SK SD1 and SD2
SD3-SK SD3
Terminal covers and separators (from shroud kits)
NH size Amps
Terminal covers (1) Separator (3)
Cat. no. Carton qty. Cat. no. Carton qty.
00* 160 CS00* 6 BC00* 2
0160 CS0 6 BC0 2
1 250 CS1 6 BC1-2 2
2 400 CS2 6 BC1-2 2
3 630 CS3 6 BC3 2
* For single pole only
Phase barrier kits*
Catalog no. Fits fuse block
SD12-PB SD1 and SD2
SD3-PB SD3
* Kits include 2 phase barriers and 2 ganging links.
5-12 BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
IEC and British Standard fuses — 5
IEC and British
Standard fuses
Class gG IEC 60269 industrial ferrule fuses
Data sheet no. 720115
ØE
ØA
CD
B
.22x58mm, Class gG, 400, 500 and 690 Vac, 2 to 125 A
Catalog no.
Standard W/ striker Vac Amps IR (kA) Holder/block
C22G2
690
2
80 CH22 DIN-Rail*,
JM70100 block
C22G4 C22G4S 4
C22G6 C22G6S 6
C22G8 C22G8S 8
C22G10 C22G10S 10
C22G12 C22G12S 12
C22G16 C22G16S 16
C22G20 C22G20S 20
C22G25 C22G25S 25
C22G32 C22G32S 32
C22G40 C22G40S 40
C22G50 C22G50S 50
C22G63 C22G63S 63
C22G80 C22G80S 500 80
C22G100 C22G100S 100 120
C22G125 C22G125S 400 125
* Use striker version to actuate optional, external microswitch.
Dimensions — mm
Catalog
symbol Ø A B C
Indicator/striker
DØ E
C10G 10 38 10
C14G 14.3 51 13 8 4
C22G 22 58 16 8 4
10 to 22mm diameter IEC Class gG fuses with optional indicators
(10x38mm only) and strikers. See catalog numbers for availability
and ratings.
10x38mm, Class gG, 500 and 400 Vac, 0.5 to 32 A
Catalog no.
Standard W/ indicator Vac Amps IR (kA) Holder/block
C10G0.5
500
0.5
120 CHM DIN-Rail*,
BMM block
C10G1 1
C10G2 2
C10G4 4
C10G6 6
C10G8 8
C10G10 10
C10G12 12
C10G16 16
C10G20 20
C10G25 25
C10G32 400 32
C10G32 400 32
C10G321 500 32
C10G40I 500 40
C10G50I 400 50
* Not recommended for use with indicator version.
14x51mm, Class gG, 400, 500 and 690 Vac, 1 to 50 A
Catalog no.
Standard W/ striker Vac Amps IR ( kA) Holder
C14G1 690 180
CH14 DIN-Rail**
C14G2 2
C14G2S 500 120
C14G4 690 480
C14G4S 500 120
C14G6 690 680
C14G6S 500 120
C14G8 690 880
C14G8S 500 120
C14G10 690 10 80
C14G10S 500 120
C14G12 690 12 80
C14G12S 500 120
C14G16 690 16 80
C14G16S 500 120
C14G20 690 20 80
C14G20S 500 120
C14G25 690 25 80
C14G25S
500 120
C14G32 C14G32S 32
C14G40 C14G40S 40
C14G50 C14G50S 400 50
** Not recommended for use with indicator version, use striker version to actuate
optional, external microswitch
5-13
BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
5 — IEC and British Standard fuses
Class aM IEC 60269 industrial ferrule fuses
Data sheet no. 720115
22x58mm, Class aM, 400, 500 and 690 Vac, 2 to 125 A
Catalog no.
Standard
W/
indicator W/ striker Vac Amps IR (kA) Holder/block
C22M2
690
2
80
CH22 DIN-Rail*,
JM70100 block
C22M4 4
C22M6 6
C22M8 8
C22M10 10
C22M12 C22M12S 12
C22M16 C22M16S 16
C22M20 C22M20S 20
C22M25 C22M25S 25
C22M32 C22M32S 32
C22M40 C22M40S 40
C22M50 C22M50S 50
C22M63 C22M63S 63
C22M80 C22M80S 500 80
120C22M100 C22M100S 100
C22M125 C22M125I C22M125S 400 125
* Not recommended for use with indicator version, use striker version to actuate
optional, external microswitch.
Dimensions — mm
ØE
ØA
CD
B
10 to 22mm diameter IEC Class aM fuses with optional indicators
(22x58mm only) and strikers. See catalog numbers for availability
and ratings.
10x38mm, Class aM, 500 and 400 Vac, 0.25 to 25 A
Catalog no.
Standard Vac Amps IR (kA) Holder/block
C10M0.5
500
0.5
CHM Din-Rail,
BMM block
C10M1 1
C10M2 2
C10M4 4
C10M6 6
C10M8 8
C10M10 10
C10M12 12
C10M16 16
C10M20 400 20
C10M25 25
14x51mm, Class aM, 400, 500 and 690 Vac, 0.25 to 50 A
Catalog no.
Standard W/ striker Vac Amps IR (kA) Holder
C14M0.25
690
0.25
C14M0.5 0.5
CH14 DIN-Rail**
C14M1 1 80
C14M2 280
C14M2S 500 120
C14M4 690 480
C14M4S 500 120
C14M6 690 680
C14M6S 500 120
C14M8 690 880
C14M8S 500 120
C14M10 690 10 80
C14M10S 500 120
C14M12 690 12 80
C14M12S 500 120
C14M16 690 16 80
C14M16S 500 120
C14M20 690 20 80
C14M20S 500 120
C14M25 690 25 80
C14M25S
500 120
C14M32 C14M32S 32
C14M40 C14M40S 40
C14M50 C14M50S 400 50
** Use striker version to actuate optional, external microswitch.
Catalog
symbol Ø A B C
Indicator/striker
DØ E
C10M 10 38 10
C14M 14.3 51 13 8 4
C22M 22 58 16 8 4
5-14 BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
IEC and British Standard fuses — 5
IEC and British
Standard fuses
HRC fuse holders
CAMaster
The Bussmann series CAMaster
HRC fuse holder features a
unique cam-action for easy
fuse removal while allowing
significantly improved contact
pressure between fuse carrier
and base contact that enhances
electrical performance. A range
of lockable safety carriers for the
fuse holder (catalog reference
LSC), are available.
Ratings
Volts 690 V
Amps up to 100 A
Agency information
CSA C22.2 No. 39; IEC 269 and BS88, CE
Catalog no. Amps Details for Fuses accepted
CM20CF 30 HRCI-CA applications _CIF21
CM30CF 30 _H07C
CM60CF 60 HRCII applications _K07C
CM100CF 10 0 _K07CR
Accessories
Catalog no. Amps Description CAMaster accepted
20BS 30
Back stud
CM20CF
32BS 30 CM30CF
60/100BS 60/100 CM60/100CF
GLP All Ganging link kit 3-Pole
20LSC 30
Security carrier
with clip
CM20CF
32LSCC 30 CM30CF
63/100LSC 60/100 CM60/100CF
SAFEloc
The Bussmann series SAFEloc
HRC fuse holders (for use with
HRCI-CB fuses) provides a
positive, stress-free fuse fitting
and locks it in position to ensure
safe insertion and withdrawal
from the base. Base contacts are
fully shrouded to help protect
against electric shock. Shrouds
utilize simple slide/snap action
allowing access to the contact
terminal screws. It can be
mounted on a 35mm DIN-Rail
or panel-mounted with a single
screw.
Ratings
Volts 600 V
Amps 30-60 A
Agency information
Designed to accommodate the compact range of offset blade fuse
to CSA C22.2 No. 106, HRCI-CB, CE
Catalog no.* Amps Connection Fuses accepted
C30F
30
Front
_CIF06C30BS Back
C30FBS Front-back
C60F
60
Front
EK-(amp)C60BS Back
C60FBS Front-back
* For use with HRCI-CB fuses.
Bussmann series Red Spot fuse holders
These versatile CSA Certified and IP20 finger-safe fuse holders for
BS88 HRC industrial fuses are available in ratings from 20 to 400
amps.
Padlock inserts, warning carriers and fuse adapter accessories
enhance safety and application flexibility.
See data sheet no. 10083 for details.
5-15
BUSSMANN SERIES FULL LINE CATALOG 1007 — JUNE 2017 Eaton.com/bussmannseries
It’s easier than ever to improve
your circuit protection while
efciently reducing your fuse
inventory.
Leveraging Bussmann™ series
ultimate protection fuses, our
Low-Peak™ Upgrade program
couples the industry’s most
advanced circuit protection with
our extensive knowledge to deliver
enganced safety, improved system
reliability and simplied inventory.
In just three simple steps,
you’ll save time and increase
productivity. All by using
Bussmann series Low-Peak fuses.
BUSSMANN
SERIES
Follow us on social media to get the
latest product and support information.
Enhanced safety.
Improved system reliability.
Simplified inventory.
Audit
Analyze
Implement
1
2
3
Three steps to ultimate protection:
Visit Eaton.com/bussmannseries to
learn more.