DHS-12
DHS250B
DC-DC Converters Bus Converter .Power Module Type
DH S 250 B 05 -O
Ordering information
R
1 2 3 4 5 6
1 Series name
2 Single output
3 Output wattage
4 B : DC200-400V
5 Output voltage
6 Optional
T : with Mounting hole
(f3.4 thru)
MODEL DHS250B03 DHS250B05 DHS250B07 DHS250B12 DHS250B15 DHS250B24 DHS250B28 DHS250B48
MAX OUTPUT WATTAGE[W] 165.0 250.0 247.5 252.0 247.5 252.0 252.0 249.6
DC OUTPUT 3.3V 50A 5V 50A 7.5V 33A 12V 21A 15V 16.5A 24V 10.5A 28V 9.0A 48V 5.2A
SPECIFICATIONS
MODEL DHS250B03 DHS250B05 DHS250B07 DHS250B12 DHS250B15 DHS250B24 DHS250B28 DHS250B48
INPUT
VOLTAGE[V] DC200 - 400
CURRENT[A]
*1
0.67A 1.0A 1.0A 1.0A 1.0A 1.0A 1.0A 1.0A
EFFICIENCY[%]
*1
88.0typ 90.0typ 88.0typ 88.0typ 88.0typ 88.0typ 88.0typ 89.0typ
OUTPUT
VOLTAGE[V] 3.3 5 7.5 12 15 24 28 48
CURRENT[A] 50 50 33 21 16.5 10.5 9.0 5.2
LINE REGULATION[mV] 10max 10max 20max 24max 30max 48max 56max 96max
LOAD REGULATION[mV] 10max 10max 20max 24max 30max 48max 56max 96max
RIPPLE[mVp-p]
0 to +100C
*2
80max 80max 100max 120max 120max 120max 120max 200max
-40
to
0C
*2
120max 120max 130max 150max 150max 150max 150max 250max
0 to 15% Load
*2
160max 160max 200max 240max 240max 240max 240max 400max
RIPPLE NOISE[mVp-p]
0 to +100C
*2
120max 120max 130max 150max 150max 150max 150max 250max
-40
to
0C
*2
200max 200max 200max 200max 200max 250max 250max 400max
0 to 15% Load
*2
240max 240max 260max 300max 300max 300max 300max 500max
TEMPERATURE REGULATION[mV]
0 to +65C
35max 50max 70max 120max 150max 240max 280max 480max
-40 to +100C
66max 100max 140max 240max 300max 480max 560max 960max
DRIFT[mV]
*
3
16max 20max 30max 40max 60max 90max 90max 180max
START-UP TIME[ms] 200max (DCIN 280V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
*
4
Fixed (TRM pin open), adjustable by external VR or external voltage
1.98 - 3.96 3.00 - 6.00 4.50 - 8.25
7.20 - 13.20 9.00 - 16.50 14.40 - 26.40 16.80 - 30.80 28.80 - 52.80
OUTPUT VOLTAGE SETTING[V]
3.30 - 3.40 4.97 - 5.13 7.43 - 7.67
11.91 - 12.29 14.76 - 15.24 23.62 - 24.38 27.56 - 28.44 47.24 - 48.76
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
4.20 - 4.85 6.30 - 7.30
8.70 - 10.20 13.90 - 16.35 17.25 - 20.25 27.60 - 32.40 32.20 - 37.80 55.20 - 64.80
REMOTE SENSING Provided
REMOTE ON/OFF Provided (Neqative Logic L : ON, H :OFF)
ISOLATION
INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY AGENCY APPROVALS UL60950-1, C-UL, EN60950-1
OTHERS CASE SIZE/WEIGHT 58.4X12.7X61mm [2.3X0.5X2.4 inches](WXHXD) / 100g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 At rated input(DC280V) and rated load.
*2
Ripple and ripple noise is measured by using measuring board. Refer to the manual.
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*4
Refer to the manual for input range.
* Providing heat sink
as option