4 advancedenergy.com
COOLX600 SERIES
Reliabilty
Parameter Conditions/Description Min Nom Max Units
Reliability and MTBF MTBF of > 400 kHours, Telecordia SR-332, Issue 1 CoolMod — 0.52 — Fpmh
CoolPac — 1.08 — Fpmh
Warranty 5 years ————
Environmental
Parameter Conditions/Description Min Nom Max Units
Operating Temperature Operates to specification below -20°C after 10 min warmup -40 — 85 °C
Storage Temperature -40 — 85 °C
Derating See Derating Curves including note 5 — — — —
Relative Humidity Non-condensing 5 — 95 %RH
Shock and Vibration MIL-STD-810G Method 514.6 — — — —
Altitude — — 5000 m
Leakage Currents
Parameter Conditions/Description Nom Units
AC Leakage Current Input to Earth Ground — —
Normal Condition (High Line) Mains Voltage 264 VAC / 60 Hz 248 µA
Single Fault Condition (High Line) Mains Voltage 264 VAC / 60 Hz 393 µA
Touch Current
Normal Condition Mains Voltage 264 VAC / 60 Hz 4.7 µA
Single Fault Condition Mains Voltage 264 VAC / 60 Hz 247 µA
EMC
Parameter Conditions/Description Units
Radiated Emissions4EN 55011, EN 55022 and FCC, Class B Compliant
Conducted Emissions4EN 55011, EN 55022 and FCC, Class B Compliant
Power Line Harmonics EN 61000-3-2, Class A Compliant
Voltage Flicker EN 61000-3-3 Compliant
ESD EN 61000-4-2, level 4, 8 kV contact, 15 kV air A
Radiated Immunity EN 61000-4-3, level 2, 3 V/m A
Electrical Fast Transient EN 61000-4-4, level 4, ±4 kV B
Surge Immunity EN 61000-4-5, level 4, 2 kV DM, 4 kV CM B
Conducted RF Immunity EN 61000-4-6, level 3, 10 Vemf 150 KHz-80 MHz A
Power Frequency Magnetic Field EN 61000-4-8, level 4, 30 A/m A
4 Consult AE applications for system level compliance
Standards and Directives4
Parameter Conditions/Description
Safety Agency Approvals EN60601-1 3rd Edition, UL60601-1, CSA601
EN60950 2nd Edition, CSA C22.2 No. 60950-1
IEC/EN 60950-1, Edition 2 and
All National Deviations
UL 60950-1/CSA 22.2 No 60950-1, Edition 2
5000 m (16,400 ft) altitude, 100 V to 240 ±10% VAC
IEC/EN 60601-1, Edition 3 and
All National Deviations
IEC 60601-1(2005), EN60601-1 (2006)
ANSI/AAMI ES 60601-1 (2005)
CAN/CSA C22.2 No. 60601-1 (2008)
5,000 m (16,400 ft) altitude, 100 V to 240 VAC ±10%
ELECTRICAL SPECIFICATIONS (CONTINUED)