1 Low Signal Relay G5V-2
Low Signal Relay
G5V-2
Suitable for handling low signals in computer peripherals,
telecommunications and security equipment.
Capable of switching loads up to 2 A.
Conforms to FCC part 68 1500 V surge withstand.
Reliable bifurcated crossbar contacts.
Fully-sealed construction.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-2-DC12).
Specifications
Contact Data
Type Contact form Construction Model
Standard DPDT Fully-sealed G5V-2
High-sensitivity G5V-2-H
Ultra-sensitive G5V-2-H1
Item Standard and high-sensitivity Ultra-sensitive
Load Resistive load (p.f. = 1)
Rated load 0.50 A at 125 VAC
2 A at 30 VDC
0.5 A at 125 VAC
1 A at 24 VDC
Contact material Ag (Au clad)
Carry current 2 A
Max. operating voltage 125 VAC
125 VDC
Max. operating current 2 A 1 A
Max. switching capacity 62.5 VA
60W
62.5 VA
24W
Min. permissible load 10 µA, 10 mVDC
Low Signal Relay G5V-2 2
Coil Data
Standard Type
High-sensitivity Type
Ultra-sensitive Type
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C (73°F).
Rated voltage
(VDC)
Rated current
(mA)
Coil
resistance
()
Coil inductance
(Ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature OFF Armature ON % of rated voltage
3 166.70 18 0.04 0.05 75% max. 5% min. 120% max.
at 65°C
(149°F)
Approx. 500
5 100 50 0.09 0.11
6 83.30 72 0.16 0.19
9 55.60 162 0.31 0.49
12 41.70 288 0.47 0.74
24 20.80 1,152 1.98 2.68
48 12 4,000 -- -- 110% max.
at 60°C
(140°F)
Approx. 580
Rated voltage
(VDC)
Rated current
(mA)
Coil
resistance
()
Coil inductance
(Ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature OFF Armature
ON
% of rated voltage
3 120 25 0.04 0.07 75% max. 5% min. 120% max.
at 70°C
(158°F)
Approx. 360
572700.120.19
6 60 100 0.18 0.29
9 40 225 0.40 0.62
12 30 400 0.75 1.18
24 15 1,600 3.16 4.81
48 7.5 6,400 -- -- 110% max.
at 70°C
(158°F)
Rated voltage
(VDC)
Rated current
(mA)
Coil
resistance
()
Coil inductance
(Ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature OFF Armature
ON
% of rated voltage
3 50 60 0.18 0.26 75% max. 5% min. 150% max.
at 70°C
(158°F)
Approx. 150
5 30 166.7 0.46 0.47
6 25 240 0.70 0.97
9 16.70 540 1.67 2.33
12 12.50 960 2.90 3.99
24 8.30 2,880 6.72 9.27 Approx. 120
48 6.25 7,680 20.10 26.70 Approx. 300
3 Low Signal Relay G5V-2
Characteristics
Note: Data shown are of initial value.
Characteristic Data
Contact resistance 50 m max. G5V-2, G5V-2-H, 100 m max. G5V-2-H1
Operate time 7 ms max. (mean value: approx. 3.5 ms)
Release time 3 ms max. (mean value: approx. 0.8 ms)
Bounce time Operate Mean value: approx. 0.5 ms
Release Mean value: approx. 3.5 ms
Operating frequency Mechanical 36,000 operations/hour
Electrical 1,800 operations/hour (under rated load)
Insulation resistance 1,000 M min (at 500 VDC)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same poles
(500 VAC, 50/60 Hz for 1 minute between contacts of same poles for ultra-sensitive type)
Surge withstand voltage 1,500 V 10 X 160 µs (conforms to part 68 of FCC rules)
Vibration Mechanical durability 10 to 55 Hz, 1.50 mm (0.59 in) double amplitude
Malfunction durability
Shock Mechanical durability 1,000 m/s2 (approx. 100 G)
Malfunction durability 200 m/s2 (approx. 20 G), 100 m/s2 (approx. 10 G) for ultra-sensitive type
Ambient temperature Operating/storage -25° to 70°C (-13° to 158°F)
Humidity 35% to 85% RH
Service life Mechanical 15 million operations min. (at operating frequency of 36,000 operations/hour)
Electrical See “Characteristic Data”
Weight 6 g (0.21 oz)
Rated operating voltage (V) Rated operating current (A) Rated operating current (A)
--- 48 VDC coil voltage (standard type)
All other types and voltages
Maximum voltage (%)
Service life (X103 operations)
Rated operating current (A)
Maximum Switching Capacity Electrical Service Life Ambient Temperature vs. Maximum Voltage
Low Signal Relay G5V-2 4
Dimensions
Unit: mm (inch)
Relays
Fully-sealed Terminal arrangement/Internal Mounting holes
(bottom view) (bottom view)
Note: 1. and indicate mounting orientation marks.
2. A tolerance of ±0.10 (0.004) applies to the above dimensions.
Approvals
UL (File No. E41515)/CSA (File No. LR24825)
Note: 1. The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this catalog.
2. In the interest of product improvement, specifications are subject to change.
3. UL1950 recognition.
Type Contact form Coil rating Contact ratings
G5V-2
G5V-2-H
DPDT 3 to 48 VDC
3 to 24 VDC
0.6 A, 125 VAC
0.6 A, 110 VDC
2.0 A, 30 VDC
G5V-2-H1 3 to 48 VDC 0.5 A, 125 VAC
0.6 A, 125 VAC
0.2 A, 110 VDC
0.6 A, 110 VDC
1.0 A, 24 VDC
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.ca
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
Cat. No. GC RLY8 5/03 Specifications subject to change without notice Printed in USA
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
416-286-6465
OMRON ELECTRONICS LLC
One Commerce Drive
Schaumburg, IL 60173