cui.com
date 01/24/2019 │ page 3 of 11CUI Inc │ SERIES: PYBE20 │ DESCRIPTION: DC-DC CONVERTER
OUTPUT (CONTINUED)
parameter conditions/description min typ max units
cross regulation
dual output models:
main output 50% load
secondary output from 10~100% load
±5 %
start-up time nominal input, constant resistive load 10 ms
adjustability8see application notes ±10 %
switching frequency9PWM mode 270 kHz
transient recovery time 25% load step change, nominal input voltage 300 500
transient response deviation
25% load step change, nominal input voltage
3.3, 5, ±5 Vdc output models
all other models
±5
±3
±8
±5
%
%
at full load ±0.03 %/°C
Note: 8. For single output models only.
9. Value is based on full load. At loads <50%, the switching frequency decreases with decreasing load
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection 110 160 %
over current protection 110 190 %
short circuit protection hiccup, continuous, self recovery
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output for 1 minute at 1 mA 1,500 Vdc
isolation resistance input to output at 500 Vdc 1,000
isolation capacitance
input to output, 100 kHz / 0.1 V
PYBE20-Q24-S24
all other models
2,050
1,050
pF
pF
safety approvals10, 11 UL 60950-1, EN 62368-1
conducted emissions
radiated emissions
ESD
radiated immunity
EFT/burst
surge
conducted immunity
voltage dips & interruptions
MTBF 1,000,000 hours
yes
Note: 10. UL approval only for board mount models.
Additional Resources: Product Page | 3D Model | PCB Footprint