Page:13/15
5. Reliability Test Items
(Note3)
Item Test Conditions Remark
High Temperature Storage Ta = 7 0℃ 240hrs Note 1,Note 4
Low Temperature Storage Ta = - 3 0 ℃ 240hrs Note 1,Note 4
High Temperature Operation Ts = 6 0℃ 240hrs Note 2,Note 4
Low Temperature Operation Ta = -2 0℃ 240hrs Note 1,Note 4
Operate at High Temperature
and Humidity +40℃, 90%RH 240hrs Note 4
Thermal Shock
-30℃/30 min ~ +70℃/30 min for a total 100
cycles, Start with cold temperature and end
with high temperature.
Note 4
Vibration Test
Frequency range:10~55Hz
Stroke:1.5mm
Sweep:10Hz~55Hz~10Hz
2 hours for each direction of X. Y. Z.
(6 hours for total)
Mechanical Shock 100G 6ms,±X, ±Y, ±Z 3 times for each
direction
Package Vibration Test
Random Vibration :
0.015G*G/Hz from 5-200HZ, -6dB/Octave
from 200-500HZ
2 hours for each direction of X. Y. Z.
(6 hours for total)
Package Drop Test Height:60 cm
1 corner, 3 edges, 6 surfaces
Electro Static Discharge ± 2KV, Human Body Mode, 100pF/1500Ω
Note 1: Ta is the ambient temperature of samples.
Note 2: Ts is the temperature of panel’s surface.
Note 3: In the standard condition, there shall be no practical problem that may affect the
display function. After the reliability test, the product only guarantees operation,
but don’t guarantee all of the cosmetic specification.
Note 4: Before cosmetic and function test, the product must have enough recovery time,
at least 2 hours at room temperature.