Monolithic InGaP HBT MMIC Amplier
Page 3 of 4
ISO 9001 ISO 14001 AS 9100 CERTIFIED
Mini-Circuits®
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661
The Design Engineers Search Engine Provides ACTUAL Data Instantly at
®
Notes: 1. Performance and quality attributes and conditions not expressly stated in this specification sheet are intended to be excluded and do not form a part of this specification sheet. 2. Electrical specifications
and performance data contained herein are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. 3. The parts covered by this specification sheet are subject to
Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard
Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp.
For detailed performance specs
& shopping online see web site
minicircuits.com
IF/RF MICROWAVE COMPONENTS
Product Marking
Recommended Application Circuit
Test Board includes case, connectors, and components (in bold) soldered to PCB
RAM-7+
Case Style: AF190
Suggested Layout for PCB Design: PL-254
Ceramic surface-mount, .083 body diameter, lead nish: tin/silver/nickel
Evaluation Board: TB-414-7+
7” inch reels with 20, 50, 100, 200, 500, 1000 devices.
Tape & Reel: F14
7” inch reels with 20, 50, 100, 200, 500, 1000 devices.
Additional Detailed Technical Information
Additional information is available on our web site. To access this information enter the model number on
our web site home page.
Environmental Ratings: ENV08T6
Performance data, graphs, s-parameter data set (.zip le)
A07
R BIAS
Vcc “1%” Res. Values (ohms)
for Optimum Biasing
7 137
8 182
9 226
10 274
11 316
12 365
13 412
14 453
15 499
4
2
3
1
C block
IN
C block
Ibias
OUT
Vd
R FC (Optional)
C bypas
Vcc
R bias (R equired)
Markings in addition to model number designation may appear for internal quality control purposes.