EPDX 00 - KY 30-05 ORANGE
Operating temperature, range
-40 .. 105 °C
Generated 10/12/06 for abdelfattah kamal - http://www.nexans.co.uk/e-service/ Page 1 / 2
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: 10037900
Country ref.: 084858OXX1
Unscreened hook-up wires
Standards
National NF C 32-070/C1; NF
C 93-521
Description
APPLICATION
Theses wires are mainly designed for internal wiring in electronic
equipment. They are fire retardant (to NF C 32-070/C1 French
specification).
STANDARDS
NF C 93-521.
MAIN CHARACTERISTICS
Operating voltage: 250 and 750 Volts
Operating temperature: - 40° C up to + 105°C (ambient temperature +
rise).
CONSTRUCTION
CONDUCTOR
Stranded (KY30 and KY33A) annealed tinned copper wires
1.
INSULATION
high temperature PVC
2.
Contact
Cables for Industrial
Applications
Nexans House, Chesney Wold,
Bleak Hall
MK6 1LA Milton Keynes
United Kingdom
Phone: 01908 250850
Fax: 01908 250851
mick.hayman@nexans.com
EPDX 00 - KY 30-05 ORANGE
Generated 10/12/06 for abdelfattah kamal - http://www.nexans.co.uk/e-service/ Page 2 / 2
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans ref.: 10037900
Characteristics
Construction characteristics
Conductor material Tinned annealed copper
Type of conductor Circular, stranded
Insulation PVC
Wire colour Orange
Outer sheath Unsheathed
Dimensional characteristics
Number of cores 1
Conductor cross-section (AWG) 22
Conductor cross-section 0.34 mm²
Number of core wires (nb x mm Ø) 7 x 0.25 mm Ø
Diameter, range 1.20 .. 1.45 mm
Approximate weight (kg/km) 4.3 kg/km
Electrical characteristics
Operating voltage (V) 250 V
Usage characteristics
Operating temperature, range -40 .. 105 °C
Length (m) 250 m
Packaging Coil