STANDARD
MICROCIRCUIT DRAWING
SIZE
A
86025
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990 REVISION LEVEL
F SHEET 3
DSCC FORM 2234
APR 97
DEPARTMENT OF DEFENSE SPECIFICATION
MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard Electronic Component Case Outlines.
DEPARTMENT OF DEFENSE HANDBOOKS
MIL-HDBK-103 - List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Copies of these documents are available online at https://assist.daps.dla.mil/quicksearch/ or from the Standardization
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-
JAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer
Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-
PRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying
activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan
may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device.
These modifications shall not affect the PIN as described herein. A "Q" or "QML" certification mark in accordance with MIL-
PRF-38535 is required to identify when the QML flow option is used. This drawing has been modified to allow the manufacturer
to use the alternate die/fabrication requirements of paragraph A.3.2.2 of MIL-PRF-38535 or other alternative approved by the
qualifying activity.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38535, appendix A and herein.
3.2.1 Terminal connections. The terminal connections shall be as specified on figure 1.
3.2.2 Truth table. The truth table shall be as specified on figure 2.
3.2.3 Logic diagram. The logic diagram shall be as specified on figure 3.
3.2.4 Case outlines. The case outlines shall be in accordance with 1.2.2 herein.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full case operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are described in table I.
3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN listed
in 1.2 herein. In addition, the manufacturer's PIN may also be marked.
3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance
to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a "Q" or "QML" certification mark in
accordance with MIL-PRF-38535 to identify when the QML flow option is used. For product built in accordance with A.3.2.2 of
MIL-PRF-38535, or as modified in the manufacturer’s QM plan, the “QD” certification mark shall be used in place of the "Q" or
"QML" certification mark.