Datasheet Rev. FB1
Issued 2006/02
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
1
Power PCB Relay RP II/2
I2 pole 8, 2 C/O or 2 N/O contacts
I4 kV / 8 mm coil-contact
ITwin contacts available
IPCB-sockets
IRoHS compliant (Directive 2002 / 95 / EC)
as per product date code 0404
Applications
Domestic appliances, UPS's
Approvals
V
,
Z
Technical data of approved types on request
Contact data
Configuration 2 C/O contact or 2 N/O contact
Type of contact single contact
Rated current 8 A (UL: 10 A)
Rated voltage / max.breaking voltage AC 250 Vac / 440 Vac
Maximum breaking capacity AC 2000 VA
Make current (max. 4 s at duty cycle 10%) 14 A
Contact material AgNi 0.15, AgCdO
Contact ratings
Type Load Operations Standard
RP440 64 A ON, 2 A OFF, 250 Vac 1x104VDE 0860
RP421 2 A, 50 Vdc, resistive approx. 2x106
RP421 1/10hp, 240 Vac, per contact UL 508
RP421 3 A, 380 Vac, AC11 approx. 3x104VDE 0660
RP421 0.18 A, 110 Vdc, DC11 approx. 1x105VDE 0660
RP420
0.6 A, 220 Vac, cosϕ=0.8, single phase motor
approx. 1.3x106
Coil data
Nominal voltage 5...110 Vdc
Nominal coil power 500 mW
Operate category 2 / b
Coil versions, DC-coil
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vdc Vdc Vdc Vdc cmA
005 5 3.5 0.5 9.0 54+10% 92.6
006 6 4.2 0.6 10.8 68+10% 88.2
012 12 8.4 1.2 21.6 270+10% 44.4
024 24 16.8 2.4 43.2 1100+15% 21.8
048 48 33.6 4.8 86.4 4400+15% 10.9
060 60 42.0 6.0 108.0 6540+15% 9.2
110 110 77.0 11.0 198.0 23100+15% 4.8
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request
F0150-B
Datasheet Rev. FB1
Issued 2006/02
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
2
Power PCB Relay RP II/2 (Continued)
Insulation
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 250
Other data
RoHS - Directive 2002 / 95 / EC
compliant as per product date code 0404
Ambient temperature -40...+70 °C
Mechanical life 20x106operations
Max. switching rate at rated- / minimum load 10 min-1 / 1200 min-1
Operate- / release time typ. 9 / 3 ms
Bounce time N/O contact/N/C contact typ. 2 / 3 ms
Vibration resistance N/O / N/C contact 11 / 1.5 g, 30...150 Hz
Shock resistance (destruction) 100 g
Category of protection (IEC 61810) RT II - flux proof, RT III - wash tight
Relay weight 18 g
Packaging unit 20 / 500 pcs.
Accessories see accessories RT and RP
PCB layout / terminal assignment
Bottom view on solder pins
Dimensions in mm
Dimensions
Dimensions in mm
2 C/O contacts
2 N/O contacts
S0163-CO
S0163-BJ
S0163-BK
S0273-AB
Datasheet Rev. FB1
Issued 2006/02
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Specifications subject to
change.
General Purpose Relays
3