OCXO-DELTA 1. Specification Frequency range: 2,048 MHz ... 16.384 MHz Standard frequencies ( 1 ) : Standard frequencies ( 2 ), multiplied frequencies : Type: Frequency stability in the temperature range - 20C to + 70C: vs. supply voltage changes UB 5 %: vs. load changes 50 Ohm 10 %: Long term stability after 30 days of operation: 4.096; 5.0; 5.120; 6.4; 8.192; 10.0; 10.23; 10.24; 10.368 MHz 12.0; 12.8; 13.0; 14.4; 16.384 MHz B C < + 2.5x10-8 ( 1 ) < + 5x10-8 ( 2 ) < + 1x10-7 ( 3 ) < + 5x10-9 ( 1 ) < + 1x10-8 ( 2 ) < + 2x10-8 ( 3 ) < + 2x10-9 < + 2x10-9 < + 1x10-9 < + 1x10-9 < + 3x10-9 per day < + 1x10-7 per year < + 5x10-10 per day < + 5x10-8 per year < + 1x10-11 Short term stability: Frequency control range with ext. trimmer 20 kOhm or external voltage 1 ... 5 V: > + 4x10-7 > + 3x10-7 12 V 10 % Supply voltage UB: Current consumption at steady state @ - 20C: @ + 25C: < 50 mA < 40 mA < 120 mA < 95 mA Peak Current consumption during warm-up: < 400 mA < 600 mA Warm-up time within < + 1x10-7: within < + 5x10-8: Temperature ranges Operating: Storage: Output voltage : load : duty cycle : < 7min.@ -20C < 5min.@ +25C < 8.5min.@ -20C < 7.0min.@ +25C -20C ... + 70C -55C ... + 85C HCMOS Low < 1.0 V; High > 4.0 V 1 kOhm // 15 pF max.2TTL or 10HCMOS 45 / 55 % USA: Vectron International * 166 Glover Avenue, Norwalk, CT 06856 * Tel: 1-88-VECTRON-1 * Fax: 1-888-FAX-VECTRON EUROPE: In Denmark, Finland, Ireland, Italy, Israel, Norway, Spain, UK: Tel: 44(0) 1703 766 288 * Fax: 44 (0) 1703 766 822 In Austria, Belgium, France, Germany, Luxembourg, Netherlands, Sweden, Switzerland: Tel: 49 (0) 72 63 648 0 * Fax: 49(0) 72 63 619 6 ASIA: In China, Taiwan, Japan: Tel: 1-603-598-0075 * In Korea, Singapore, Australia, India: Tel: 1-203-853-4433 * Fax: 1-203-849-1423 www.vectron.com Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. OCXO-DELTA Phase noise: Frequencies ( 1 ): 1 Hz 10 Hz 100 Hz 1000 Hz 10000 Hz Frequencies ( 2 ): 1 Hz 10 Hz 100 Hz 1000 Hz 10000 Hz - 85 dBc/Hz -120 dBc/Hz -130 dBc/Hz -140 dBc/Hz -150 dBc/Hz - 80 dBc/Hz -115 dBc/Hz -130 dBc/Hz -140 dBc/Hz -150 dBc/Hz Phase noise: phase noise freq.2 phase noise freq.1 -80 -90 -90 -100 -100 L(f) [dBc/Hz] L(f) [dBc/Hz] -80 -110 -110 -120 -120 -130 -130 -140 -140 -150 -150 -160 1 10 100 f [Hz] 1000 10000 -160 1 10 100 1000 10000 f [Hz] Typical phase noise for type OCXO-DELTA C1X , 5 MHz: Ordering data: e.g. OCXO-DELTA 16,384 MHz, Version C temperature stability: < + 1x10-8 : Case: BF-131 code Z : C 2 Z OCXO-DELTA C2Z, 16,384 MHz USA: Vectron International * 166 Glover Avenue, Norwalk, CT 06856 * Tel: 1-88-VECTRON-1 * Fax: 1-888-FAX-VECTRON EUROPE: In Denmark, Finland, Ireland, Italy, Israel, Norway, Spain, UK: Tel: 44(0) 1703 766 288 * Fax: 44 (0) 1703 766 822 In Austria, Belgium, France, Germany, Luxembourg, Netherlands, Sweden, Switzerland: Tel: 49 (0) 72 63 648 0 * Fax: 49(0) 72 63 619 6 ASIA: In China, Taiwan, Japan: Tel: 1-603-598-0075 * In Korea, Singapore, Australia, India: Tel: 1-203-853-4433 * Fax: 1-203-849-1423 www.vectron.com Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. OCXO-DELTA 2. Environmental conditions Shock: DIN IEC 68-2-27,Test Ea, 100 g, 6ms Half-sine, 3 bumps in 3 main directions Vibration: DIN IEC 68-2-6, Test Fc, 10-500Hz, 10g, 2 h in 3 main directions Humidity: DIN IEC 68-2-3, 40C/93%RH, 21 days Solderability: DIN IEC 68-2-20 only for wire leads, Methode 3: Solder globule at + 235C 3. Marking Manufacturer's name, date code(week/year) Specification Center frequency 4. Case Case style: BF-133 67 x 60 x 30 mm ( X ) Pin configuration 1. RF-output 2. Potentiometer ( Vref out ) 3. Ground, case, potentiometer 4. Potentiomer SL ( VC in ) 5. Supply voltage USA: Vectron International * 166 Glover Avenue, Norwalk, CT 06856 * Tel: 1-88-VECTRON-1 * Fax: 1-888-FAX-VECTRON EUROPE: In Denmark, Finland, Ireland, Italy, Israel, Norway, Spain, UK: Tel: 44(0) 1703 766 288 * Fax: 44 (0) 1703 766 822 In Austria, Belgium, France, Germany, Luxembourg, Netherlands, Sweden, Switzerland: Tel: 49 (0) 72 63 648 0 * Fax: 49(0) 72 63 619 6 ASIA: In China, Taiwan, Japan: Tel: 1-603-598-0075 * In Korea, Singapore, Australia, India: Tel: 1-203-853-4433 * Fax: 1-203-849-1423 www.vectron.com Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. OCXO-DELTA Case style: BF-138 51,3 x 41,3 x 25 mm ( Y ) Pin configuration 1. Ground, case, potentiometer 2. Potentiometer SL ( VC in ) 3. Potentiometer ( Vref out ) 4. Supply voltage 5. RF-output Case style: BF-131 50 x 50 x 25,4 mm ( Z ) 1.Pin configuration 1. Potentiometer SL ( VC in ) 2. Potentiometer ( Vref out ) 3. RF-output 4. Ground, case, potentiometer 5. Supply voltage 5. Test circuits USA: Vectron International * 166 Glover Avenue, Norwalk, CT 06856 * Tel: 1-88-VECTRON-1 * Fax: 1-888-FAX-VECTRON EUROPE: In Denmark, Finland, Ireland, Italy, Israel, Norway, Spain, UK: Tel: 44(0) 1703 766 288 * Fax: 44 (0) 1703 766 822 In Austria, Belgium, France, Germany, Luxembourg, Netherlands, Sweden, Switzerland: Tel: 49 (0) 72 63 648 0 * Fax: 49(0) 72 63 619 6 ASIA: In China, Taiwan, Japan: Tel: 1-603-598-0075 * In Korea, Singapore, Australia, India: Tel: 1-203-853-4433 * Fax: 1-203-849-1423 www.vectron.com Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. OCXO-DELTA Test circuit BF-131 20 kOhm 2 Oscillator +UB O 1 5 A O Oscilloscope, Counter or Spectrum Analyzer RE = 50 Ohm O Oscilloscope, Counter or Spectrum Analyzer RE = 50 Ohm O Oscilloscope, Counter or Spectrum Analyzer RE = 50 Ohm 975 Ohm 3 4 V 15 pF 50 Ohm GND O Test circuit BF-133 20 kOhm 2 Oscillator +UB O 4 5 A 975 Ohm 1 3 V 15 pF 50 Ohm GND O Test circuit BF-138 20 kOhm 3 Oscillator +UB O 2 4 A 975 Ohm 5 1 V 15 pF 50 Ohm GND O USA: Vectron International * 166 Glover Avenue, Norwalk, CT 06856 * Tel: 1-88-VECTRON-1 * Fax: 1-888-FAX-VECTRON EUROPE: In Denmark, Finland, Ireland, Italy, Israel, Norway, Spain, UK: Tel: 44(0) 1703 766 288 * Fax: 44 (0) 1703 766 822 In Austria, Belgium, France, Germany, Luxembourg, Netherlands, Sweden, Switzerland: Tel: 49 (0) 72 63 648 0 * Fax: 49(0) 72 63 619 6 ASIA: In China, Taiwan, Japan: Tel: 1-603-598-0075 * In Korea, Singapore, Australia, India: Tel: 1-203-853-4433 * Fax: 1-203-849-1423 www.vectron.com Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.