Voltage/Current
Design Max
Vf/If Vf/If
V/C Table I
5V/75mA 5.5V/85mA
6V/40mA 7V/60mA
12V/30mA 14V/40mA
15V/30mA 16.5V/35mA
24V/30mA 26V/35mA
28V/25mA 30V/28mA
48V/20mA 52V/22mA
60V/16mA 65V/18mA
120VAC/9.5mA 130VAC/10.5mA
Voltage/Current
Design Max
Vf/If Vf/If
V/C Table II
5V/26mA 5.5V/35mA
6V/28mA 7V/39mA
12V/15mA 14V/22mA
15V/15mA 16.5V/19mA
24V/15mA 26V/18mA
28V/15mA 30V/18mA
48V/9mA 50V/9.5mA
60V/6.5mA 65V/7.2mA
120VAC/5mA 130VAC/5.5mA
445 S. Douglas Street, El Segundo, CA 90245-4630 • (800) 421-6815 • (310) 640-0442 • FAX (310) 640-7639
www.datadisplay.com
© 2005 Data Display Products
61
Data Display Products®
TO ORDER, FOLLOW THE EXAMPLE:
Voltage[3]
5
6
12
15
24
28
48
60
120
Lens
-CW
Model LED Voltage Lens
1116W -R 12 -CW
LED
-R
-O
-A
-G
-B
-W
-L
Color
RED
ORG
AMB
GRN
BLU
CWHT
WWHT
V/C
Table[2]
I
I
I
II
II
II
II
Iv[1]
(mcd)
2800 (*4)
2000 (*4)
2800 (*4)
2400 (*2)
700 (*2)
2500 (*2)
1800 (*2)
λpk
(nm)
634
609
592
520
465
3
4
1234
Select one BOLD component from each numbered category in the tables below.
Part Number 1116W-R12-CW
2
Model Wires
1116 W
(optional)
1
[1] Iv = typical luminous intensity @ If = 20mA(Ta=25°C). (*4) = 4 LEDs per package;
(*2) = 2 LEDs per package.
[2] See Voltage/Current table for design specifications.
[3] Ta = 25°C. Voltages 6 through 60 are VDC. For AC operation, insert D after Voltage (e.g 24AC),
not required for 120V. Contact factory for VAC design currents. For 120 VDC, insert DC after
Voltage (e.g. 120DC).
1116
Standard Wire Leads:
6.0" total length(nominal)/.50" stripped (nominal), red
anode/black cathode, 18 AWG stranded UL1015 insula-
tion. Contact factory for other lengths, gauges and colors.
All dimensions are in inches (mm)
Tolerances: .xx"(.x) ±.025"(.63) / .xxx"(.xx)±.010"(.25)
Specifications are subject to change without notice.
11 /16" MOUNT PANEL LIGHT WITH LENS
High Intensity, Wide Angle