PowerPlus DC * Optically Isolated MOSFET output * Ratings from 10A to 60A @ 48 VDC * AC control * Relays are easily paralleled for higher-current applications * LED Status Indicator * Optional IP20 Cover * UL Recognized, CE and RoHS Compliant PRODUCT SELECTION Control Voltage 10A 20A DC60A10 90-140 VAC DC60A20 40A DC60A40 60A DC60A60 AVAILABLE OPTIONS Control Voltage A: 90-140 VAC Series DC Cover Blank: Not Included C: Included 100 A Operating Voltage 60: 7-48 VDC 40 C Thermal Pad Blank: Not Included H: Included H Rated Load Current 10: 10 Amps 20: 20 Amps (Not valid with 400A suffix) 40: 40 Amps (Not valid with 400x suffixes) 60: 60 Amps (Not valid with 200A, 400x suffixes) OUTPUT SPECIFICATIONS (1) Description Operating Voltage [Vdc] (2) Blocking Voltage Rated Load Current [Adc] (3) Minimum Load Current [mA] (4) Maximum Surge Current [Adc] (10ms) Maximum On-State Voltage Drop @ Rated Current [Vdc] Maximum Off-State Leakage Current @ Rated Voltage [mA] Thermal Resistance Junction to Case (Rjc) [C/W] Maximum On-State Resistance @ Rated Current [RDS-ON][mOhms] 10A 1-48 VDC 60 10 2.5 78 0.33 0.1 2.1 33.4 20A 1-48 VDC 60 20 2.5 108 0.35 0.1 1.2 17.6 40A 1-48 VDC 60 40 2.5 163 0.62 0.1 1.1 15.6 60A 7-48 VDC 60 60 2.5 200 0.62 0.1 0.8 10.4 INPUT SPECIFICATIONS (1) Description DCxxxAxx Control Voltage Range Minimum Input Current @ min Control Voltage [mA] Maximum Input Current @ max Control Voltage [mA] Nominal Input Impedance Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] 90-140 VAC 11 13 Current Regulated 10 10 Description Parameters GENERAL SPECIFICATIONS Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 V DC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range (5) Ambient Storage Temperature Range Housing Material Weight (typical) (6) Encapsulation (7) Terminal Finish Recommended Terminal Screw Torque (6-32) [in lbs/Nm] Recommended Terminal Screw Torque (8-32) [in lbs/Nm] GENERAL NOTES 1) All parameters at 40C and per section unless otherwise specified. 2) Maximum voltage is 60VDC 3) Heat sinking required, see derating curves. 4) Low current loads and high ambient temperature can affect turn-on time. 5) Maximum Ambient Operating Temperature for the AC control relays is 65C 6) Typical weight for the AC control realys is 2.99 oz/85g. 7) AC controlled relays contain thermal conductive epoxy. MECHANICAL SPECIFICATIONS 2500 Vrms 109 Ohm 10 pF -30 to 80C -40 to 125 C Valox 420 SEO Black, UL 94 V-0 2.65 oz (75g) Epoxy Free Electroless Nickel 10/1.1 20/2.2 WIRING DIAGRAM AGENCY APPROVALS IEC 61000-4-2 Electrostatic Discharge Level 3, Criteria A IEC 61000-4-4 Electrically Fast Transients Level 3, Criteria A IEC 61000-4-5 Electrical Surges Level 3, Criteria A E116950 072312 THERMAL DERATE INFORMATION ANNEX - ENVIROMENTAL INFORMATION