www.clare.com
2
CPC1393
R03
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Ratings Units
Peak Blocking Voltage 600 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1100 mW
Total Package Dissipation 2550 mW
Isolation Voltage, Input to Output 5000 Vrms
Operational Temperature -40 to +85 ºC
Storage Temperature -40 to +125 ºC
1 Derate Linearly 1.33 mW/ºC
2 Derate Linearly 3.00 mW/ºC
Electrical absolute maximum ratings are at 25ºC
Absolute Maximum Ratings
Electrical Characteristics
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Current
Continuous - IL--90
mA
Peak t=10ms ILPK - - 350
On-resistance 1IL=90mA RON -3550 Ω
Off-State Leakage Current VL=600V ILEAK -- 1 μA
Switching Speeds
Turn-On IF=5mA, VL=10V TON -- 5
ms
Turn-Off TOFF -- 5
Output Capacitance IF=0mA, VL=50V, f=1MHz COUT -50 - pF
Input Characteristics @ 25°C
Input Control Current IL=90mA IF- 0.55 2
mA
Input Dropout Current - IF0.2 - -
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10 μA
Common Characteristics @ 25°C
Input to Output Capacitance - CI/O -3 - pF
1 Within 1 second of time.