40 Industrial Way East, Eatontown , NJ 07724 [USA]
Phone: (732) 460-0212, Fax: (732) 460-0214
www.aeroflex.com/acc, email: acc-sales@aeroflex.com
Parameter Specification Units
Frequency Range (min) 18 - 26 GHz
Flatness v.s. Frequency 800 dB
Minimum Output Voltage 4 mV
Specifications:
Features:
• Contains hermetically sealed modules, inter-
nal RF matching, DC return, and RF bypass
capacitor.
• The video port is protected from static or
transient charges.
• Input impedance matching.
• Models may be chosen for broadband RF
performance of for optimized narrow bands
Revision Date: 2/23/2011
ACTP-1799
High Frequency Tunnel Detector
Notes:
Maximum input power: +14dBm (3dB guardband for
+17dBm possible burnout)
Sensitivity is measured into an open circuit load
(>10k ohm).
Environmental Specifications:
Designed to meet:
MIL-E-5400, MIL-STD-202, MIL-E-16400
Operating Temp: -55°C to +125°C
Storage Temp: -65°C to +150°C
Humidity: MIL-STD-202F, M103, Cond B
Shock: MIL-STD-202F, M213, Cond B
Altitude: MIL-STD-202F, M105, Cond B
Vibration: MIL-STD-202F, M204, Cond B
Thermal Shock: MIL-STD-202F, M107, Cond A
Temperature Cycle: MIL-STD-202F, M105C, Cond D
SCREENING:
Internal Visual per MIL-STD-883, Method 2017
Temperature Cycle: -65°C to +100°C, 10 cycles
OPTIONAL HIGH-REL SCREENING
(Ref MIL-PRF-38534):
Stabilization Bake per MIL-STD-883, Method 1008
Temperature Cycle per MIL-STD-883, Method 1010
Constant Acceleration per MIL-STD-883, Method
2001
Burn-in per MIL-STD-883, Method 1015
Leak Test per MIL-STD-883, Method 1014
External Visual per MIL-STD-883, Method 2009