Expert diffuse-mode sensor with a visible red beam
QPMA
E
U
R
O
-
S
T
Y
L
E
P
I
G
T
A
I
L
P
U
R
C
A
B
L
E
C
A
L
L
F
A
C
T
O
R
Y
Easy-to-set automatic Expert-style Static and Dynamic TEACH options, multiple
Single-Point Set options, plus manual adjustment for fine tuning
Smart power-control algorithm to maximize performance in low-contrast applica-
tions
Normal mode provides 1.8 ms sensing response with improved crosstalk avoid-
ance routine (for two sensors) and improved fluorescent light immunity
Selectable high-speed (HS) mode option for 300-microsecond response (crosstalk
avoidance and fluorescent light immunity disabled)
Easy push-button Dark Operate/Light Operate select, output OFF-delay, and oper-
ating speed setup
Powerful, highly collimated visible red sensing beam
Easy-to-read operating status indicators, with 8-segment bar graph display
Bipolar discrete outputs, PNP and NPN
Selectable 30-millisecond OFF-delay
Compact housing, mounting versatility – via popular 30 mm threaded barrel or
side-mount
Tough ABS housing is rated IEC IP67; NEMA 6
Models available with 2 m or 9 m (6.5 ft or 30 ft) cable or integral quick-disconnect
Models Range Cable Supply Voltage Output Type
QS30EDV High-Speed Mode: 1,100 mm (43 inches
Normal Mode: 1,400 mm (55 inches)
2 m (6.5 ft) 5-wire cable
10 to 30V dc Bipolar NPN/PNP
QS30EDVQ Integral 5-pin Euro-style QD
Standard 2 m (6.5 ft) cable models are listed. To order the 9 m (30 ft) cable model, add suffix "W/30" (QS30EDV W/30). A model with a
QD connector requires a mating cable; see Accessories on page 10.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does NOT include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
Overview
The QS30EDV is an easy-to-use diffuse-mode sensor. It provides high-perform-
ance sensing in low-contrast applications. Its visible red beam provides easy sen-
sor alignment. The sensor offers multiple configuration options, in addition to man-
ual fine adjustment, remote programming, and security lockout options.
The sensor features bipolar outputs, one each NPN and PNP.
The sensor’s compact housing has a large, easy-to-see bar graph display plus
bright LEDs for easy configuration and status monitoring during operation. LEDs 1
through 4 of the bar graph display also show configuration status during setup.
The sensor can be side-mounted, using its integral mounting holes, or front-moun-
ted, via its 30 mm threaded barrel.
Output LED (yellow)
Power ON LED (green)
Configuration
push buttons
Bargraph display(red)
LEDs 1-4 also display
configuration status
Switching threshold
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
P/N 127755 Rev. C 4/1/2013
0 127755 5
Sensor Configuration
Sensor configuration is accomplished through TEACH or Set options, plus Setup mode. After TEACH or Set have defined the sensing
parameters, Setup mode may be used to enable the delay, to change the Light Operate/Dark Operate status, or to select the high-speed
response option (HS). Manual Adjust may be used to fine-tune the thresholds (see Bar Graph Indicator Functions on page 8). Two
push buttons, Dynamic (+) and Static (-), or the remote wire, may be used to access and set the parameters.
Sensor configuration options include:
Two-Point Static TEACH: a single switching threshold, determined by two taught conditions.
Dynamic (on-the-fly) TEACH: a single switching threshold, determined by multiple sampled conditions.
Window Set: a sensing window, centered on a single sensing condition.
Light Set and Dark Set: a single switching threshold, offset from a single sensing condition.
Remote Configuration
The remote function may be used to configure the sensor remotely or to disable the push button for security. Connect the gray wire of the
sensor to ground (0V dc), with a remote programming switch connected between them. Pulse the remote line according to the diagrams
in the configuration procedures. The length of the individual programming pulses is equal to the value T where: 0.04 seconds ≤ “T” ≤ 0.8
seconds
Returning to Run Mode
Configuration modes each may be exited either after the 60-second time-out or by exiting the process in one of the two following ways:
In static TEACH or SET modes, press and hold the Static (-) button (or hold the remote line) for 2 seconds. The sensor returns to Run
mode without saving any new settings.
In SETUP mode, press and hold both the Static (-) and Dynamic (+) buttons (or hold the remote line) for 2 seconds. The sensor
returns to Run mode and saves the current setting.
Two-Point Static TEACH (Threshold)
Sets a single switching threshold (switching point)
Threshold position is adjustable using “+” and “-” buttons (Manual Adjust).
Recommended for applications where two conditions can be presented by the
user.
Two-Point TEACH is the traditional configuration method. The sensor locates a sin-
gle switchpoint at the optimal location between the two taught conditions, with the
Output ON condition on one side, and the Output OFF condition on the other.
The first condition taught is the ON condition. The Output ON and OFF conditions
can be reversed by changing Light/Dark Operate status in Setup Mode.
Sensor positions
threshold midway
between taught conditions
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF Output ON
2nd Taught
Condition
1st Taught
Condition
Position
adjusted by
Manual Adjust
Two-Point TEACH and Manual Adjust
Using Manual Adjust with Two-Point TEACH moves the switching threshold position. The lighted LED on the bar graph moves to exhibit
the received signal, relative to the threshold.
Bargraph LED (Following TEACH) Relative Signal Difference/Recommendation
6 to 8 Excellent: Very stable operation.
4 to 5 Good: Minor variables will not affect sensing reliability.
2 to 3 Low: Minor sensing variables may affect sensing reliability.
1 Unreliable: Consider an alternate sensing scheme.
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
2 www.bannerengineering.com - tel: 763-544-3164 P/N 127755 Rev. C
Push Button Remote Line
Result
0.04 seconds ≤ “Click” ≤ 0.8
seconds
0.04 seconds ≤ T ≤ 0.8 sec-
onds
Access TEACH
Mode
Press and hold Static (-) button
for more than 2 seconds
No action required; sensor is
ready for 1st TEACH condi-
tion.
Power LED: OFF
Output LED: ON
Bar graph: #5 and 6 alternately flash
TEACH Output
ON Condition
Present Output ON condition
and click the Static (-) button
Present Output ON condition
and single-pulse the remote
line
Power LED: OFF
Output LED: Flash, then OFF
Bar graph: #5 and 6 alternately flash
TEACH Output
OFF Condition
Present Output OFF condition
and click the Static (-) button
Present Output OFF condi-
tion and single-pulse the re-
mote line
TEACH Accepted
Power LED: ON
Bar graph: One LED flashes to show relative con-
trast (good signal difference shown; see table
above)
Sensor returns to RUN mode
TEACH Unacceptable
Power LED: OFF
Bar graph: #1, 3 and 5, 7 alternately flash to show
failure
Sensor returns to “TEACH Output ON Condition”
Dynamic TEACH and Adaptive Thresholds
• Teach on-the-fly
• Sets a single switching threshold (switching point)
• Threshold position is adjustable using “+” and “-” buttons (Manual Adjust)
• Recommended for applications where a machine or process may not be stop-
ped for teaching.
Dynamic TEACH is a variation of two-point TEACH. It programs the sensor during
actual machine run conditions, taking multiple samples of the light and dark condi-
tions and automatically setting the threshold at the optimum level.
Dynamic TEACH activates the sensor’s adaptive threshold system, which continu-
ously tracks minimum and maximum signal levels, and automatically maintains cen-
tering of the threshold between the light and dark conditions. The adaptive threshold
system remains in effect during Run mode. The adaptive routine saves to non-vola-
tile memory at least once per hour.
Sensor positions
threshold midway
between taught conditions
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF Output ON
Darkest Taught
Condition
Lightest Taught
Condition
Position
adjusted by
Manual Adjust
When Dynamic TEACH mode is used, the output ON state (Light or Dark Operate) will remain as it was last programmed. To change the
output ON state, use Setup Mode.
The sensing threshold may be adjusted (fine-tuned) whenever the sensor is in RUN mode by clicking the “+” and “-” buttons. However,
when a manual adjustment is made, the adaptive threshold system is disabled (cancelled).
Bar Graph LED (Following TEACH) Relative Signal Difference/Recommendation
6 to 8 Excellent: Very stable operation.
4 to 5 Good: Minor variables will not affect sensing reliability.
2 to 3 Low: Minor sensing variables may affect sensing reliability.
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
P/N 127755 Rev. C www.bannerengineering.com - tel: 763-544-3164 3
Bar Graph LED (Following TEACH) Relative Signal Difference/Recommendation
1 Unreliable: Consider an alternate sensing scheme.
Push Button Remote Line Result
Access Dynamic
TEACH Mode
Press and hold Dynamic (+)
push button for more than 2
seconds
Hold the remote line low (to
ground) for more than 2 sec-
onds
Power LED: OFF
Output LED: OFF
Bargraph: #7 and 8 alternately flash
TEACH Sensing
Conditions
Continue to hold push button
(+) and present the Output ON
and OFF conditions
Continue to hold remote line
low (to ground) and present
the Output ON and OFF con-
ditions
Power LED: OFF
Output LED: OFF
Bargraph: #7 and 8 alternately flash
Return to Run
Mode Release push button (+) Release the remote line/
switch
TEACH Accepted
Power LED: ON
Bargraph: One LED flashes to show relative con-
trast (good signal difference shown; see table
above)
Sensor returns to RUN mode with new settings
TEACH Unacceptable
Power LED: OFF
Bargraph: #1, 3 and 5, 7 alternately flash to show
failure
Sensor returns to RUN mode without changing
settings
Single-Point Window Set
Sets a single ON condition that extends 12.5% above and below the taught condi-
tion.
All other conditions (lighter or darker) result in OFF output
Sensing window size (sensitivity) is adjustable using the “+” and “-” buttons (Manual
Adjust)
Recommended for applications where the target to be sensed may not always ap-
pear in the same place, or when other signals may appear.
Single-Point Set designates a sensing window, by setting two switching thresholds at
12.5% above and below the presented condition. The Output ON condition is inside the
window, and the Output OFF conditions are outside the window when Light Operate is
selected. Output ON and OFF conditions can be reversed by changing Light/Dark Op-
erate status in Setup mode.
Sensor positions
window thresholds
12.5% from the
presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Condition
Presented
Sensing window size
adjusted by
Manual Adjust
Output OFF Output OFFOutput ON
Single-Point Window Set and Manual Adjust
Using Manual Adjust with Single-Point Window Set expands or contracts the size of the window. The lighted LEDs on the light bar sepa-
rate to a greater or lesser extent to exhibit the relative sensing window size.
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
4 www.bannerengineering.com - tel: 763-544-3164 P/N 127755 Rev. C
Push Button Remote Line
Result
0.04 seconds ≤ “Click” ≤
0.8 seconds
0.04 seconds ≤ T ≤ 0.8
seconds
Access Set Mode
Press and hold Static (-)
push button for more than 2
seconds
Single-pulse the remote line
Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Bar graph: #5 and 6 alternately flash
Set Sensing Con-
dition
Present the sensing condi-
tion and double-click the
Static (-) push button
Present the sensing condi-
tion and double-pulse the re-
mote line
Threshold Conditions Accepted
Power LED: ON
Bar graph: 2 indicators flash together to show the
threshold conditions are accepted
Sensor returns to RUN mode with new settings
Threshold Conditions Unacceptable
Power LED: OFF
Bar graph: #1, 3 and 5, 7 alternately flash to show
failure
Sensor returns to “SET Sensing Condition”
Single-Point Light Set
Sets a threshold 12.5% below the taught condition.
Any condition darker than the threshold condition causes the output to change
state.
Threshold position is adjustable using the “+” and “-” buttons (Manual Adjust).
Recommended for applications where only one condition is known, for example
a stable light background with varying darker targets.
A single sensing condition is presented, and the sensor positions a threshold 12.5%
below the presented condition. When a condition darker than the threshold is
sensed, the output either turns ON or OFF, depending on the Light/Dark Operate
setting (see Setup Mode on page 6).
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold 12.5% below
the presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF Output ON
Condition
Presented
Light Set and Light/Dark Operate Selection
In Light Operate mode, Light Set teaches the Output ON condition. In Dark Operate mode, Light Set teaches the Output OFF condition.
Push Button Remote Line Result
0.04 seconds ≤ “Click” ≤
0.8 seconds
0.04 seconds ≤ T ≤ 0.8
seconds
Access Set Mode Press and hold Static (-)
push button for more than 2
seconds
Single-pulse the remote
line
Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Bar graph: #5 and 6 alternately flash
Set Sensing Condi-
tion
Present the sensing condi-
tion and click the Static (-)
push button four times
Present the sensing con-
dition and four-pulse the
remote line
Threshold Condition Accepted
Power LED: ON
Bar graph: Indicators #5–8 flash together to show that
the threshold condition is accepted
Sensor returns to RUN mode with new settings
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
P/N 127755 Rev. C www.bannerengineering.com - tel: 763-544-3164 5
Push Button Remote Line Result
0.04 seconds ≤ “Click” ≤
0.8 seconds
0.04 seconds ≤ T ≤ 0.8
seconds
Threshold Condition Unacceptable
Power LED: OFF
Bar graph: #1, 3 and 5, 7 alternately flash to show fail-
ure
Sensor returns to “SET Sensing Condition”
Single-Point Dark Set
Sets a threshold 12.5% above the taught condition.
Any condition lighter than the threshold condition causes the output to change
state.
Threshold position is adjustable using the “+” and “-” buttons (Manual Adjust).
Recommended for applications where only one condition is known, for example a
stable dark background with varying lighter targets.
A single sensing condition is presented, and the sensor positions a threshold 12.5%
above the taught condition. When a condition lighter than the threshold is sensed, the
output either turns ON or OFF, depending on the Light/Dark Operate setting (see
Setup Mode on page 6).
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold 12.5% above
the presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF Output ON
Condition
Presented
Dark Set and Light/Dark Operate Selection
In Light Operate mode, Dark Set teaches the Output OFF condition. In Dark Operate mode, Dark Set teaches the Output ON condition.
Push Button Remote Line
Result
0.04 seconds ≤ “Click” ≤
0.8 seconds
0.04 seconds ≤ T ≤
0.8 seconds
Access Set Mode
Press and hold the Static
(-) push button for more
than 2 seconds
Single-pulse remote
line
Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Bar graph: #5 and 6 alternately flash
Set Sensing Con-
dition
Present the sensing condi-
tion and click the Static (-)
push button five times
Present the sensing
condition and five-pulse
the remote line
Threshold Condition Accepted
Power LED: ON
Bar graph: Indicators #1–4 flash together to show that the
threshold condition is accepted
Sensor returns to Run mode with new settings
Threshold Condition Unacceptable
Power LED: OFF
Bar graph: #1, 3 and 5, 7 alternately flash to show failure
Sensor returns to “Set Sensing Condition”
Setup Mode
Setup mode is used to change sensor output response for:
Light or Dark operate
30-millisecond pulse stretcher (OFF delay), if required.
300 μs high-speed response
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
6 www.bannerengineering.com - tel: 763-544-3164 P/N 127755 Rev. C
If Setup mode programming is interrupted and remains inactive for 60 seconds, the sen-
sor returns to Run mode with the most recent settings (e.g., exits and saves current se-
lection). Setup mode operates in the “background” while the outputs are active; changes
are updated instantly.
Push Button Remote Line
Result
0.04 seconds ≤ “Click” ≤
0.8 seconds
0.04 seconds ≤ T ≤ 0.8
seconds
Access Setup Mode
Press and hold both push but-
tons (+ and -) for more than 2
seconds
Double-pulse the remote
line
Green Power LED turns OFF
Output LED remains active
Status indicators (bar graph #1–4) flash current
setup
Select Setting Combi-
nation
Click either push button (+ or
-) until the LEDs show the de-
sired settings
Pulse the remote line until
the LEDs show the desired
settings.
NOTE: Double-pulsing the
remote line causes the set-
ting to “back up” one step.
Sensor rotates through eight setting combina-
tions, in the following order:
1. Normal Speed - No Delay - LO*
2. Normal Speed - No Delay - DO
3. Normal Speed - Delay - LO
4. Normal Speed - Delay - DO
5. High Speed - No Delay - LO
6. High Speed - No Delay - DO
7. High Speed - Delay - LO
8. High Speed - Delay - DO
* Factory default setting
Return to Run Mode
Press and hold both push but-
tons (+ and -) for more than 2
seconds
Hold the remote line low
for more than 2 seconds
Green Power LED turns ON
Sensor returns to RUN mode with new settings
Manual Adjust
Manual Adjust is used during Run mode and is accomplished via the push buttons only. Its behavior depends on whether a switching
threshold or a sensing window is used.
Switching Threshold:
Fine-tunes sensing sensitivity
Press “+” to increase; press “-” to decrease
Sensing Window:
Adjusts sensing window size (tolerance) for the single-point target condition
Press “+” to increase; press “-” to decrease
The lighted bargraph LEDs move to reflect the increase or decrease.
Enabling or Disabling the Push Button
In addition to its programming function, the remote line may be used to disable the push buttons for security. Disabling the push buttons
prevents undesired tampering with the sensor configuration settings.
1. Connect the sensor’s gray wire.
2. Four-pulse the remote line to enable or disable the push button.
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
P/N 127755 Rev. C www.bannerengineering.com - tel: 763-544-3164 7
The sensor toggles between enable and disable settings and returns to RUN mode.
Bar Graph Indicator Functions
Run Mode. The lighted bar graph segment represents relative distance from the cutoff point. Its behavior depends on whether a sensing
window or a sensing threshold is taught.
Sensing Window
Above window
Inside window
Below window
Switching Threshold
Above threshold
Below threshold
More light
Signal intensity
Less light
Signal intensity
Specifications
General Performance
Sensing Beam
660 nm visible red
Power
Supply voltage: 10 to 30V dc (10% max. ripple) @ 25
mA max current, exclusive of load
Supply protection circuitry: Protected against reverse
polarity, over voltage, and transient voltages
Delay at power-up: 250 ms; outputs do not conduct
during this time
Adjustments
2 push buttons and remote wire
Easy push-button configuration; manually adjust (+/–)
cutoff (push buttons only); Light Operate/Dark Operate
and OFF-delay configuration options (push buttons on-
ly); Push-button lockout (from remote wire only)
Indicators
8-segment red bar graph: distance relative to cutoff
point
Green LED: Power ON
Yellow LED: Output conducting
Construction
ABS plastic housing; acrylic lens cover
Connections
5-conductor 2 m (6.5 ft) PVC cable, 9 m (30 ft) PVC ca-
ble, or 5-pin integral Euro-style quick-disconnect fitting
Output Configuration
Bipolar: 1 current sourcing (PNP) and 1 current sinking
(NPN)
Output Ratings
150 mA maximum load (derate ~ 1 mA/°C above 25
°C)
OFF-state leakage current: < 50 μA at 30V dc
ON-state saturation voltage (NPN): < 200 mV @ 10
mA; < 1V @ 150 mA
ON-state saturation voltage (PNP): < 1.25V @ 10 mA;
< 2V @ 150 mA
Output Protection
Protected against output short-circuit, continuous over-
load, transient over-voltages, and false pulse on power
up
Output Response Time
High-Speed Mode: 300 microseconds
Normal Mode: 1.8 ms
Repeatability
High-Speed Mode: 100 microseconds
Normal Mode: 150 microseconds
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
8 www.bannerengineering.com - tel: 763-544-3164 P/N 127755 Rev. C
Environmental Certifications
Rating
IP67, NEMA 6
Operating Conditions
Temperature: -10 to +55 °C (+14 to 122 °F)
Max. relative humidity: 90% @ 55 °C (non-condensing)
Vibration and Mechanical Shock
All models meet Mil. Std. 202F requirements. Method
201A (Vibration: 10 to 60 Hz max. double amplitude
0.06", maximum acceleration 10G). Also meets IEC
947-5-2 requirements: 30G, 11 ms duration, half sine
wave.
Performance Curves
Performance curves are based on the use of a 90% reflectance white test card.
1
10
100
1000
10000
E
X
C
E
S
S
G
A
I
N
DISTANCE
10 mm
(0.4")
100 mm
(3.9")
1000 mm
(39.4")
10000 mm
(393.7")
QS30EDV Series
High Speed
Normal Speed
Figure 1. Excess Gain Curve
1500 mm
(59.0")
1200 mm
(47.2")
900 mm
(35.4")
600 mm
(23.6")
300 mm
(11.8")
0
0
-4 mm
-8 mm
-12 mm
4 mm
8 mm
12 mm
0
-0.16"
-0.31"
-0.47"
0.16"
0.31"
0.47"
DISTANCE
QS30EDV Series
High Speed
Normal Speed
B
E
A
M
W
I
D
T
H
Figure 2. Beam Pattern
Dimensions
Cabled Models QD Models
22.0 mm
(0.87")
5.0 mm
(0.20")
32.5 mm
(1.28")
LO
HS
static dynamic
DO
33.0 mm
(1.30")
Emitter
28.8 mm
(1.13")
Receiver
17.6 mm
(0.69")
12.5 mm
(0.49")
3.5 mm
(0.14")
44.0 mm
(1.73")
1.3 mm
(0.05")
13.0 mm
(0.51")
35.0 mm
(1.38")
2 x ø3.3 mm (0.125")
max. torque
0.7 Nm (6 in lbs)
M30 x 1.5 Thread
max. torque
6 Nm (53 in lbs)
with included 30 mm
mounting nut
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
P/N 127755 Rev. C www.bannerengineering.com - tel: 763-544-3164 9
Cabled Models QD Models
Hardware included: (10) M3 x 0.5 x 28 stainless steel machine
screws, nuts and washers
Hookups
Cabled Models QD Models
bn
Remote Teach
bu
wh
bk
gy
+10 - 30V dc
Load
Load
150 mA max. load
bn
Remote Teach
bu
wh
bk
gy
+10 - 30V dc
Load
Load
150 mA max. load
Accessories
5-Pin Threaded M12/Euro-Style Cordsets (Single Ended)
Model Length Style Dimensions Pinout (Female)
MQDC1-501.5 0.50 m (1.5 ft)
Straight
44 Typ.
ø 14.5
M12 x 1
2
3
4
1
5
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
MQDC1-506 1.83 m (6 ft)
MQDC1-515 4.57 m (15 ft)
MQDC1-530 9.14 m (30 ft)
MQDC1-506RA 1.83 m (6 ft)
Right-Angle
32 Typ.
[1.26"]
30 Typ.
[1.18"]
ø 14.5 [0.57"]
M12 x 1
MQDC1-515RA 4.57 m (15 ft)
MQDC1-530RA 9.14 m (30 ft)
Brackets
SMBQS30L
Right-angle bracket for ca-
ble sensor models
Clearance for M4 (#8)
hardware
± 12° tilt adjustment
14-ga. stainless steel
Hole center spacing: A to B=35.0
Hole size: A=ø 4.3, B=ø 4.25x16.3
SMBQS30LT
Tall right-angle bracket for
QD models
± 8° tilt adjustment
14-ga. stainless steel
Hole center spacing: A to B=35.0
Hole size: A=ø 4.3, B=ø 4.25x16.3
SMBQS30Y SMBQS30YL
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
10 www.bannerengineering.com - tel: 763-544-3164 P/N 127755 Rev. C
Brackets
Heavy-duty die-cast brack-
et
M18 vertical mount option
± 8° tilt adjustment with ca-
bled units
Includes nuts and lock
washer
Hole size: A=ø 15.3
Heavy-duty die-cast brack-
et designed for industrial
protection
M18 vertical mount option
Replaceable window
Includes nuts and lock
washer
Hole size: A=ø 15.3
Other compatible mounting brackets include: SMB30MM, SMB30SC, and SMB30A
Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of
shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned
to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse,
abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (IN-
CLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND
WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL
BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPEN-
SES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY
PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WAR-
RANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or
liabilities relating to any product previously manufactured by Banner Engineering Corp.
WORLD-BEAM QS30EDV Expert Diffuse-Mode Sensor
www.bannerengineering.com - tel: 763-544-3164