278 Hermetically Sealed Relay MY4H
Contact Ratings
■Characteristics
Contact material Ag alloy
Rated load Resistive
p.f.=1
110 VAC, 3 A
24 VDC, 3A
Inductive
p.f.=0.4
L/R-7 ms
110 VAC, 0.8 A
24 VDC, 1.5 A
Rated carry current 3 A
Max. switching voltage 125 VAC, 125 VDC
Max. switching current 3 A
Max. switching power 330 VA
72 W
Contact resistance 50 mΩ max.
Operate time 20 ms max.
Release time 20 ms max.
Max. operating
frequency
Mechanical 18,000 operations/hr
Electrical 1,800 operations/hr (under rated load)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC, 1 min between coil and contacts
1,000 VAC, 1 min between contacts of different polarity
700 VAC, 1 min between contacts of same polarity
Vibration resistance Destruction 10 to 55 Hz, 1.0 mm double amplitude
Malfunction 10 to 55 Hz, 1.0 mm double amplitude
Shock resistance Destruction 1,000 m/s2
Malfunction When energized: 200 m/s2
When not energized: 200 m/s2
Endurance Mechanical: 5,000,000 operations
Electrical: 50,000 operations
Ambient temperature Operating -25 to 60°C
Storage -25 to 60°C
Ambient humidity 5% to 85%
Weight Approx. 50 g