MODEL
CDS4004802 CDS4004803 CDS4004805 CDS4004807 CDS4004812 CDS4004815 CDS4004824 CDS4004828
MAX OUTPUT WATTAGE[W] 200 330 400 405 500 510 504 504
DC OUTPUT 2V 100A 3.3V 100A 5V 80A 7.5V 54A 12.5V 40A 15V 34A 24V 21A 28V 18A
SPECIFICATIONS
MODEL
CDS4004802 CDS4004803 CDS4004805 CDS4004807 CDS4004812 CDS4004815 CDS4004824 CDS4004828
INPUT
VOLTAGE[V] DC36 - 76
CURRENT[A]
*1
6typ 9typ 10typ 10typ 12typ 12typ 12typ 12typ
EFFICIENCY[%]
DCIN 48V,Io=100%
73typ 80typ 84typ 87typ 89typ 89typ 89typ 89typ
DCIN 48V,Io=50%
75typ 82typ 86typ 88typ 91typ 90typ 90typ 90typ
OUTPUT
VOLTAGE[V] 2 3.3 5 7.5 12.5 15 24 28
CURRENT[A] 100 100 80 54 40 34 21 18
LINE REGULATION[mV] 10max 16max 20max 30max 40max 60max 95max 95max
LOAD REGULATION[mV] 20max 30max 40max 60max 100max 150max 190max 190max
RIPPLE[mVp-p]
0 to +85C
*2
80max 80max 80max 100max 120max 120max 120max 120max
-20 - 0C
*2
140max 140max 140max 150max 160max 160max 160max 160max
RIPPLE NOISE[mVp-p]
0 to +85C
*2
100max 100max 100max 140max 150max 150max 150max 150max
-20 - 0C
*2
150max 150max 150max 160max 180max 180max 180max 180max
TEMPERATURE REGULATION[mV]
0 to +65C
25max 35max 50max 75max 120max 180max 280max 280max
-20 to +85C
40max 60max 85max 130max 200max 310max 480max 480max
DRIFT[mV]
*3
10max 16max 20max 30max 40max 60max 90max 90max
START-UP TIME[ms] 200max (DCIN 48V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed (TRM pin open), 60 - 110% adjustable by external VR or external voltage
1.0 - 2.2 *4
1.98 - 3.63 3.0 - 5.5 4.50 - 8.25
7.50 - 13.75
9.0 - 16.5 14.4 - 26.4
16.8 - 32.0 *5
OUTPUT VOLTAGE SETTING[V]
1.95 - 2.10 3.25 - 3.45 4.90 - 5.20 7.25 - 7.85
12.00 - 13.00 14.40 - 15.60 23.04 - 24.96 26.88 - 29.12
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
2.80 - 4.50 4.00 - 5.50 5.75 - 7.00
8.60 - 10.50
14.35 - 17.50 17.25 - 21.00 27.60 - 33.60 33.00 - 39.20
REMOTE SENSING Provided
REMOTE ON/OFF Provided (On both side of input and output)
ISOLATION
INPUT-OUTPUT DC1500V 1minute,DC500V 50MWmin (20t15C)
INPUT-FG DC1500V 1minute,DC500V 50MWmin (20t15C)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (20t15C)
OUTPUT-RC2,RC3 AC100V 1minute,Cutoff current = 100mA,DC100V 10MWmin (20t15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*6
-20 to +85C(On aluminum base plate), 20 - 95%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +85C,20 - 95%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,49.0m/s2(5G)3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AGENCY APPROVALS UL60950-1,C-UL,EN60950-1
OTHERS CASE SIZE/WEIGHT 61X12.7X116.8mm [2.4X0.5X4.6 inches] (WXHXD)/ 180g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
123456
CDS
CDS-2
*1At rated input(DC48V) and rated load.
*2Ripple and ripple noise is measured by using measuring board with recommended capacitor
Co & the film capacitor 0.1mF.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:RM101).
*3Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*4 When using with in the range of 1-1.2V ,please consult with us.
*5 CDS4004828 : Output voltage adjustment range is 60 - 114.3%.
*6Please consult us in regard to use from -40C.