Solid State Relays G3NE CSM_G3NE_DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A * Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. * Dedicated, compact aluminum PCB and power elements used. * Built-in varistor effectively absorbs external surges. * Quick-connect #110 input terminals and #250 output connections. (#187 input terminals and #250 output connections are available.) * "-US" models certified by UL, CSA, and IEC/EN (TUV). Refer to Safety Precautions for All Solid State Relays. Model Number Structure Model Number Legend G3NE-@@@@-@-@ 2 3 4 5 6 1 7 1. Basic Model Name G3NE: Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 3. Rated Load Current 05: 5A 10: 10 A 20: 20 A 4. Terminal Type T: Quick-connect terminals 5. Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function 6. Special Specifications Blank: Standard models 2: #187 input terminals 7. Certification US: Certified by UL, CSA, and TUV Ordering Information List of Models Isolation Phototriac Zero cross function Yes Indicator No Rated output load 5 A at 100 to 240 VAC 10 A at 100 to 240 VAC 20 A at 100 to 240 VAC No 5 A at 100 to 240 VAC 10 A at 100 to 240 VAC 20 A at 100 to 240 VAC Rated input voltage (See note 1.) 5, 12, 24 VDC (See note 2.) Model G3NE-205T-US G3NE-205T-2-US G3NE-210T-US G3NE-210T-2-US G3NE-220T-US G3NE-220T-2-US G3NE-205TL-US G3NE-205TL-2-US G3NE-210TL-US G3NE-210TL-2-US G3NE-220TL-US G3NE-220TL-2-US Note: 1. The rated input voltage depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 3. 2. When ordering, specify the input voltage. 3. Refer to List of Certified Models for a list of products that comply with safety standards. When ordering a UL, CSA, and EN(TUV) certified model, add "-US" to the model number. 1 G3NE Accessories (Order Separately) Heat Sinks The following heat sinks are thin and can be DIN-track mounted. See Dimensions for details. Model Applicable SSR Y92B-N50 G3NE-205T(L)(-2)-US/-210T(L)(-2)-US Y92B-N100 G3NE-220T(L)(-2)-US Specifications Ratings (at an Ambient Temperature of 25C) Input Rated voltage Operating voltage Voltage level Must operate Input impedance Must release With zero cross function Without zero cross function 5 VDC 4 to 6 VDC 4 VDC max. 250 20% 300 20% 12 VDC 9.6 to 14.4 VDC 9.6 VDC max. 600 20% 800 20% 24 VDC 19.2 to 28.8 VDC 19.2 VDC max. 1.6 k20% 1 VDC min. Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions. Output Model Applicable load Rated load voltage Load voltage range Load current (See note 1.) With heat sink G3NE-205T(L)(-2)-US 100 to 240 VAC 75 to 264 VAC Inrush current Without heat sink 0.1 to 5 A at 40C 0.1 to 5 A at 40C 60 A (60 Hz, 1 cycle) G3NE-210T(L)(-2)-US 0.1 to 10 A at 40C (See note 2.) 0.1 to 5 A at 40C 150 A (60 Hz, 1 cycle) G3NE-220T(L)(-2)-US 0.1 to 20 A at 40C (See note 2.) 0.1 to 5 A at 40C 220 A (60 Hz, 1 cycle) Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data for details on page 3. 2. These values apply when using a dedicated heat sink or a radiation plate of specified size. Characteristics Item G3NE-2@@T(-2)-US G3NE-2@@TL(-2)-US Operate time 1/2 of load power source cycle + 1 ms max. 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 2 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Destruction: 1,000 m/s2 Ambient temperature Operating: -30C to 80C (with no icing or condensation) Storage: -30C to 100C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Certified standards UL508 File No.E64562/CSA C22.2 (No.0, No.14) File No. LR35535 TUV R9051064 (VDE0435) (EN60950) EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Weight Approx. 37 g 2 G3NE Engineering Data Load Current vs. Ambient Temperature G3NE-205T(L)(-2)-US G3NE-210T(L)(-2)-US With standard heat sink (Y92B-N100) or aluminum plate measuring 300 mm x 300 mm x t3 mm (W x H x D) Load current (A) Without heat sink Load current (A) With standard heat sink (Y92B-N50) or aluminum plate measuring 100 mm x 100 mm x t2 mm (W x H x D) Without heat sink Load current (A) G3NE-220T(L)(-2)-US Ambient temperature (C) Ambient temperature (C) Ambient temperature (C) Without heat sink One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. Energized time (ms) G3NE-220T(L)(-2)-US Inrush current (A. Peak) G3NE-210T(L)(-2)-US Inrush current (A. Peak) Inrush current (A. Peak) G3NE-205T(L)(-2)-US Energized time (ms) Energized time (ms) 3 G3NE Dimensions Note: All units are in millimeters unless otherwise indicated. G3NE-205T(L)/210T(L)/220T(L)(-2)-US 3.5 dia. hole Terminal Arrangement/ Internal Connections (Top View) 47.5 max. 37.5 max. 14.5 Input voltage Two #110 (t = 0.5) (Faston tab or equivalent)* 7.1 2.9 6.5 Input Two #250 (t = 0.8) (Faston tab or equivalent) Output 4- Load 2 7.95 6 11.5 max. 3 Load power supply Mounting Holes Two, 3.5-dia. or M3 holes * G3NE-2@@T(L)-2-US: Two, #187 (t=0.5) (Faston tab or equivalent) Heat Sink Y92B-N50 1 3+ 30+0.5 300.2 Mounting Holes 4.6 dia. hole Two, M3 holes Two, M4 holes Two, 3.2-dia. holes 44 max. 30 35 30.50.3 47.6 5.6 5 77 max. 900.3 100 max. Y92B-N100 4.6 dia. hole Two, M3 holes 47 max. 6 4.5 51 max. Weight: approx. 200 g 350.2 Two, M4 holes Two, 3.2-dia. holes Mounting Holes 71 max. 30 35 30.50.3 900.4 Two, 4.4-dia. or M4 holes 75 max. 900.4 47.6 77 max. 5 5.6 28 100 max. 13 4.5 Two, 4.4-dia. or M4 holes 900.3 100 max. 350.2 Weight: approx. 400 g Safety Precautions Precautions for Correct Use Thermal Resistance Rth (Back of Junction SSR) Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. G3NE-205T (L) 2.72 Refer to Safety Precautions for All Solid State Relays. Do not apply excessive force to the terminals. Be careful when pulling or inserting the terminal clips for the Quick Connector (QC). When attaching a heat sink to the G3NE, in order to facilitate heat dissipation, apply heat-conductive grease on the heat sink. For DIN Track mounting, use a separately sold Heat Sink. Refer to information on the G3NA. G3NE-210T(L): Y92B-N50 G3NE-220T(L): Y92B-N100 Tighten the mounting screws of the heat sink with a torque of 0.59 to 0.98 N*m. Model Thermal resistance (C/W) G3NE-210T (L) 2.12 G3NE-220T (L) 2.22 EMC Directive Compliance The G3NE complies with EMC Directives under the following conditions ("-US" models only). 10 m max. Load Input G3NE-US Output Film capacitor: * 1 F, 250 VAC * Connect a film capacitor to the load power supply. * The input cable must be less than 10 m. 4 G3NE ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 5 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.2 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: G3NE-220T-US-DC5 G3NE-220T-US-DC12 G3NE-210T-US-DC12 G3NE-205TL-US DC5 G3NE-205T-US DC12 G3NE-210T-DC12 G3NE-205T-US-DC5 G3NE-210T-2-US DC5 G3NE-220TL-US-DC24