For more Information
please call
1-800-Belden1
General Description:
18 AWG stranded (19x30) TC conductors, plenum, FEP insulation, twisted pair, overall Beldfoil® shield
(100% coverage), 20 AWG stranded TC drain wire, Flamarrest® jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
118 19x30 TC - Tinned Copper
Total Number of Conductors: 2
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
FEP - Fluorinated Ethylene Propylene 0.1778
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® with shorting fold Tape Aluminum Foil-Polyester Tape 100.000
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
20 Stranded TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material Nom. Wall Thickness (mm)
Flamarrest® LS PVC - Low Smoke Polyvinyl Chloride 0.3556
Overall Cable
Overall Nominal Diameter: 3.708 mm
Pair
Pair Color Code Chart:
Number Color
1Black & Red
Pair Lay Length & Direction:
Lay Length (mm) Twists (twist/m) Direction
50.800 19.686 Left Hand
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +75°C
Bulk Cable Weight: 29.764 Kg/Km
Max. Recommended Pulling Tension: 284.685 N
Min. Bend Radius/Minor Axis: 38.100 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMP
NEC Articles: 800
CEC/C(UL) Specification: CMP
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes