Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVE RT ERS
48 Vdc Input, 3.3 Vdc/2 A, 5 Vdc/2 A, 12 Vdc/1 A, 24 Vdc/0.5 A Output
• Isolated • Low Cost
• Fixed Frequency • Trim
• High Power Density • OCP/SCP
• High Efficiency
• Output Over-Voltage Shutdown
• Safety Approval to UL60950-1 (Pending)
• Remote On/Off
• Active Low/High (Option)
Description
The 0RLC-10T Series are isolated dc/dc converters that operate from a nominal 48 Vdc source. These units will
provide up to 12 W of output power from a nominal 48 Vdc input. These units are designed to be highly efficient
and very low cost. Features include remote on/off, over current protection and short circuit protection. These
converters are provided in an industry standard package.
Part Selection
Output
Voltage Input Voltage Max. Output
Current Max. Output
Power Typical
Efficiency Model Number
Acti ve H igh Model Num b er
Active Low
3.3 Vdc 36 Vdc - 75 Vdc 2 A 6.6 W 77% 0RLC-10T033 0RLC-10T03L
5.0 Vdc 36 Vdc - 75 Vdc 2 A 10 W 82% 0RLC-10T050 0RLC-10T05L
12 Vdc 36 Vdc - 75 Vdc 1 A 12 W 83% 0RLC-10T120 0RLC-10T12L
24 Vdc 36 Vdc - 75 Vdc 0.5 A 12 W 85% 0RLC-10T240 0RLC-10T24L
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter Min Typ Max Notes
Continuous Input Voltage -0.3 V - 75 V
Peak/Surge Input Voltage -0.3 V - 100 V Transients of 100 ms or less in duration
Remote On/Off (Active Low) -0.3 V - 18 V
Remote On/Off (Active High) -0.3 V - 7 V
Ambient Temperature 0 °C - 70 °C
Storage Temperature -40 °C - 125 °C
Input Specifications
Parameter Min Typ Max Notes
Input Voltage 36 V - 75 V
Input Current (no load) - - 40 mA
Input Current (full load) - - 0.45 A
Remote Off Input Current (Active Low) - 5 mA 10 mA
Remote Off Input Current (Active High) - 10 mA
Input Reflected Ripple Current
(pk-pk) - 15 mA 30 mA
Input Reflected Ripple Current
(rms) - 5 mA 10 mA
With simulated source impedance of
10 uH, 5 Hz to 20 MHz; use a
47uF/100 V electrolytic capacitor
with ESR = 1 ohm max. at 200 kHz
at 25 °C.
I2t Inrush Current Transient - 0.039 A2s 0.062 A2s
Turn-on Voltage Threshold - 30 V -
Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
0RLC-10Txxx Series RoHS Compliant Rev.A