For more Information
please call
1-800-Belden1
General Description:
CAT6+ (350 MHz), 4-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid
Bare Copper Conductors, Dual FRPO/FEP Insulation, Tape Separator, Ripcord, Flamarrest® Jacket
Usage (Overall)
Suitable Applications: Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG
ANYLAN, 155 ATM, 622 ATM, 250MHz Category 6
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
423 Solid BC - Bare Copper
Total Number of Conductors: 8
Insulation
Insulation Material:
Insulation Material
FRPO/FEP - Flame Retardant Polyolefin/Fluorinated Ethylene Propylene
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Flamarrest® LS PVC - Low Smoke Polyvinyl Chloride
Outer Jacket Diameter:
Nom. Dia. (mm)
5.715
Outer Jacket Ripcord: Yes
Overall Cable
Overall Cabling Separator Material: Patented Dielectric Tape
Overall Nominal Diameter: 5.715 mm
Pair
Pair Color Code Chart:
Number Color
1White/Blue Stripe & Blue
2White/Orange Stripe & Orange
3White/Green Stripe & Green
4White/Brown Stripe & Brown
Mechanical Characteristics (Overall)
Storage Temperature Range: -20°C To +75°C
Page 1 of 5 01-10-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
2413 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cables
Installation Temperature Range: +5°C To +50°C
Operating Temperature Range: 0°C To +75°C
Bulk Cable Weight: 40.181 Kg/Km
Max. Recommended Pulling Tension: 177.928 N
Min. Bend Radius/Minor Axis: 19.050 mm
Min. Bend/Installation: 57.150 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMP
CEC/C(UL) Specification: CMP
EU Directive 2011/65/EU (ROHS II): Yes
Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class E
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 10/13/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Telecommunications Standards: Category 6 - TIA 568.C.2
Applicable Patents:
Country Patent
US 5563377
US 6570095
US 6998537
US 7179999
CANADA 2144694
US 7977575
Flame Test
UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
C(UL) Flame Test: FT6
CSA Flame Test: FT6
Suitability
Suitability - Indoor: Yes
Suitability - Outdoor: No
Plenum/Non-Plenum
Plenum (Y/N): Yes
Non-Plenum Number: 2412
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/m)
49.215
Maximum Capacitance Unbalance:
Capacitance (pF/m)
1082.730
Page 2 of 5 01-10-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
2413 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cables
Maximum Capacitance Unbalance (pF/100 m): 330
Nominal Velocity of Propagation:
VP (%)
72
Maximum Delay:
Delay (ns/100 m)
537 @ 100MHz
Max. Delay Skew:
Delay Skew (ns/100 m)
35.000
Maximum Conductor DC Resistance:
DCR @ 20°C (Ohm/100 m)
7.800
Max. Operating Voltage - UL:
Voltage
300 V RMS
Maximum DCR Unbalanced:
DCR Unbalance @ 20°C (%)
3.000
Electrical Characteristics-Premise (Overall)
Premise Cable Electrical Table 1:
Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB)
12.000 75.3 75.3 73.3 73.3 20.000
43.700 66.3 66.3 62.6 62.6 23.000
85.200 61.8 61.8 56.6 56.6 24.500
10 5.800 60.3 60.3 54.5 54.5 25.000
16 7.400 57.2 57.2 49.9 49.9 25.000
20 8.300 55.8 55.8 47.5 47.5 25.000
25 9.300 54.3 54.3 45.1 45.1 24.300
31.25 10.400 52.9 52.9 42.5 42.5 23.600
62.5 15.000 48.4 48.4 33.4 33.4 21.500
100 19.300 45.3 45.3 26.0 26.0 20.800
155 24.600 42.4 42.4 17.9 17.9 19.500
200 28.300 40.8 40.8 12.5 12.5 18.700
250 32.100 39.3 39.3 7.2 7.2 18.000
300 35.600 38.1 36.1 0.5 0.5 17.500
350 38.900 37.1 35.1 -1.7 -3.7 17.000
400 42.000 36.3 34.3 -5.7 -7.7 16.600
450 45.000 35.5 33.5 -9.5 -11.5 16.200
500 47.900 34.8 32.8 -13.0 -15.0 15.900
550 50.600 34.2 32.2 -16.4 -18.4 15.600
Premise Cable Electrical Table 2:
Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance Min. ACRF (dB) Min. PSACRF (dB)
1100 ± 15 100 ± 15 70.8 67.8
4100 ± 15 100 ± 15 58.8 55.8
8100 ± 15 100 ± 15 52.7 49.7
10 100 ± 15 100 ± 15 50.8 47.8
16 100 ± 15 100 ± 15 46.7 43.7
20 100 ± 15 100 ± 15 44.8 41.8
25 100 ± 15 100 ± 15 42.8 39.8
31.25 100 ± 15 100 ± 15 40.9 37.9
62.5 100 ± 15 100 ± 15 34.9 31.9
100 100 ± 15 100 ± 15 30.8 27.8
155 100 ± 22 100 ± 15 27.0 24.0
200 100 ± 22 100 ± 15 24.8 21.8
Page 3 of 5 01-10-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
2413 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cables
250 100 ± 32 100 ± 15 22.8 19.8
300 100 ± 32 100 ± 15 21.3 18.3
350 100 ± 32 100 ± 15 19.9 16.9
400 100 ± 32 100 ± 15 18.8 15.8
450 100 ± 32 100 ± 15 17.7 14.7
500 100 ± 32 100 ± 15 16.8 13.8
550 100 ± 32 100 ± 15 16.0 13.0
Notes (Overall)
Notes: Jacket sequentially marked at 2 ft./1m intervals. Third party verified to ANSI/TIA-568-C.2, Category 6. Values above 350 MHz
are for Engineering Information Only.
Reference (Overall)
Previous Part Number: 24567415, 24567715, 24567736T, 24567615T, 25067545, 25067545T,
25067515T, 24567745T, 24567715T, 25067845, 25067845T, 25067836,
25067836T, 24567815, 24567815T, 2456705T, 24567145, 24567145T,
24567115, 24567115T, 24567345, 24567345T, 24567336, 24567336T,
24567315, 24567315T, 24567445T, 24567436, 24567436T, 24567415T,
24567A15T, 24567945, 24567945T, 24567936T, 24567915, 24567915T
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
2413 D15A1000 305 MT 13.608 KG BLUE CAT6+ 4PR U/UTP CMP RIB
2413 D15U1000 305 MT 12.701 KG BLUE CAT6+ 4PR U/UTP CMP BOX
2413 D151000 305 MT 12.701 KG BLUE CAT6+ 4PR U/UTP CMP REEL
2413 D152500 762 MT 29.484 KG BLUE CAT6+ 4PR U/UTP CMP REEL
2413 002A1000 305 MT 13.608 KG RED CAT6+ 4PR U/UTP CMP RIB
2413 003A1000 305 MT 13.608 KG ORANGE CAT6+ 4PR U/UTP CMP RIB
2413 003U1000 305 MT 12.701 KG ORANGE CAT6+ 4PR U/UTP CMP BOX
2413 0031000 305 MT 12.701 KG ORANGE CAT6+ 4PR U/UTP CMP REEL
2413 004A1000 305 MT 13.608 KG YELLOW CAT6+ 4PR U/UTP CMP RIB
2413 004U1000 305 MT 12.701 KG YELLOW CAT6+ 4PR U/UTP CMP BOX
2413 0041000 305 MT 12.701 KG YELLOW CAT6+ 4PR U/UTP CMP REEL
2413 0042500 762 MT 29.484 KG YELLOW CAT6+ 4PR U/UTP CMP REEL
2413 005A1000 305 MT 13.608 KG GREEN, DARK CAT6+ 4PR U/UTP CMP RIB
2413 005U1000 305 MT 12.701 KG GREEN, DARK CAT6+ 4PR U/UTP CMP BOX
2413 0051000 305 MT 12.701 KG GREEN, DARK CAT6+ 4PR U/UTP CMP REEL
2413 0052500 762 MT 29.484 KG GREEN, DARK CAT6+ 4PR U/UTP CMP REEL
2413 007A1000 305 MT 13.608 KG VIOLET CAT6+ 4PR U/UTP CMP RIB
2413 008A1000 305 MT 13.608 KG GRAY CAT6+ 4PR U/UTP CMP RIB
2413 008U1000 305 MT 12.701 KG GRAY CAT6+ 4PR U/UTP CMP BOX
2413 0081000 305 MT 12.701 KG GRAY CAT6+ 4PR U/UTP CMP REEL
2413 009A1000 305 MT 13.608 KG WHITE CAT6+ 4PR U/UTP CMP RIB
2413 009U1000 305 MT 12.701 KG WHITE CAT6+ 4PR U/UTP CMP BOX
2413 0091000 305 MT 12.701 KG WHITE CAT6+ 4PR U/UTP CMP REEL
2413 0092500 762 MT 29.484 KG WHITE CAT6+ 4PR U/UTP CMP REEL
2413 010A1000 305 MT 13.608 KG BLACK CAT6+ 4PR U/UTP CMP RIB
2413 010U1000 305 MT 12.701 KG BLACK CAT6+ 4PR U/UTP CMP BOX
2413 0101000 305 MT 12.701 KG BLACK CAT6+ 4PR U/UTP CMP REEL
2413 0102500 762 MT 29.484 KG BLACK CAT6+ 4PR U/UTP CMP REEL
2413 012A1000 305 MT 13.608 KG PINK CAT6+ 4PR U/UTP CMP RIB
Revision Number: 8 Revision Date: 01-07-2014
© 2014 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
Page 4 of 5 01-10-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
2413 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cables
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 5 of 5 01-10-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
2413 Multi-Conductor - Enhanced Category 6 Nonbonded-Pair Cables