W25N01GV 3V 1G-BIT SERIAL SLC NAND FLASH MEMORY WITH DUAL/QUAD SPI & CONTINUOUS READ Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV Table of Contents 1. GENERAL DESCRIPTIONS ............................................................................................................. 6 2. FEATURES ....................................................................................................................................... 6 3. PACKAGE TYPES AND PIN CONFIGURATIONS........................................................................... 7 4. 3.1 Pad Configuration WSON 8x6-mm ...................................................................................... 7 3.2 Pad Description WSON 8x6-mm .......................................................................................... 7 3.3 Ball Configuration TFBGA 8x6-mm (5x5 or 6x4 Ball Array) ................................................. 8 3.4 Ball Description TFBGA 8x6-mm ......................................................................................... 8 PIN DESCRIPTIONS ........................................................................................................................ 9 4.1 Chip Select (/CS) .................................................................................................................. 9 4.2 Serial Data Input, Output and IOs (DI, DO and IO0, IO1, IO2, IO3) ..................................... 9 4.3 Write Protect (/WP) .............................................................................................................. 9 4.4 HOLD (/HOLD) ..................................................................................................................... 9 4.5 Serial Clock (CLK) ................................................................................................................ 9 5. BLOCK DIAGRAM .......................................................................................................................... 10 6. FUNCTIONAL DESCRIPTIONS ..................................................................................................... 11 6.1 6.2 7. Device Operation Flow ....................................................................................................... 11 6.1.1 Standard SPI Instructions .....................................................................................................11 6.1.2 Dual SPI Instructions ............................................................................................................ 11 6.1.3 Quad SPI Instructions ........................................................................................................... 12 6.1.4 Hold Function ....................................................................................................................... 12 Write Protection .................................................................................................................. 13 PROTECTION, CONFIGURATION AND STATUS REGISTERS .................................................. 14 7.1 7.2 7.3 Protection Register / Status Register-1 (Volatile Writable, OTP lockable) ......................... 14 7.1.1 Block Protect Bits (BP3, BP2, BP1, BP0, TB) - Volatile Writable, OTP lockable ................. 14 7.1.2 Write Protection Enable Bit (WP-E) - Volatile Writable, OTP lockable ................................ 15 7.1.3 Status Register Protect Bits (SRP1, SRP0) - Volatile Writable, OTP lockable .................... 15 Configuration Register / Status Register-2 (Volatile Writable) ........................................... 16 7.2.1 One Time Program Lock Bit (OTP-L) - OTP lockable .......................................................... 16 7.2.2 Enter OTP Access Mode Bit (OTP-E) - Volatile Writable ..................................................... 16 7.2.3 Status Register-1 Lock Bit (SR1-L) - OTP lockable ............................................................. 16 7.2.4 ECC Enable Bit (ECC-E) - Volatile Writable ........................................................................ 17 7.2.5 Buffer Read / Continuous Read Mode Bit (BUF) - Volatile Writable .................................... 17 Status Register-3 (Status Only) .......................................................................................... 18 7.3.1 Look-Up Table Full (LUT-F) - Status Only ........................................................................... 18 7.3.2 Cumulative ECC Status (ECC-1, ECC-0) - Status Only....................................................... 18 7.3.3 Program/Erase Failure (P-FAIL, E-FAIL) - Status Only ....................................................... 19 -1- W25N01GV 7.4 8. Write Enable Latch (WEL) - Status Only ............................................................................. 19 7.3.5 Erase/Program In Progress (BUSY) - Status Only .............................................................. 19 7.3.6 Reserved Bits - Non Functional ........................................................................................... 19 W25N01GV Status Register Memory Protection ............................................................... 20 INSTRUCTIONS ............................................................................................................................. 21 8.1 8.2 9. 7.3.4 Device ID and Instruction Set Tables ................................................................................. 21 8.1.1 Manufacturer and Device Identification ................................................................................ 21 8.1.2 Instruction Set Table 1 (Continuous Read Mode, BUF = 0) ................................................. 22 8.1.3 Instruction Set Table 2 (Buffer Read Mode, BUF = 1, Default Mode after Power Up) .......... 23 Instruction Descriptions ...................................................................................................... 25 8.2.1 Device Reset (FFh) .............................................................................................................. 25 8.2.2 Read JEDEC ID (9Fh) ..........................................................................................................26 8.2.3 Read Status Register (0Fh / 05h) ......................................................................................... 27 8.2.4 Write Status Register (1Fh / 01h) ......................................................................................... 28 8.2.5 Write Enable (06h) ............................................................................................................... 29 8.2.6 Write Disable (04h) ............................................................................................................... 29 8.2.7 Bad Block Management (A1h) .............................................................................................. 30 8.2.8 Read BBM Look Up Table (A5h) .......................................................................................... 31 8.2.9 Last ECC Failure Page Address (A9h) ................................................................................. 32 8.2.10 128KB Block Erase (D8h) ................................................................................................... 33 8.2.11 Load Program Data (02h) / Random Load Program Data (84h)......................................... 34 8.2.12 Quad Load Program Data (32h) / Quad Random Load Program Data (34h) ..................... 35 8.2.13 Program Execute (10h)....................................................................................................... 36 8.2.14 Page Data Read (13h) ........................................................................................................ 37 8.2.15 Read Data (03h) ................................................................................................................. 38 8.2.16 Fast Read (0Bh) ................................................................................................................. 39 8.2.17 Fast Read with 4-Byte Address (0Ch) ................................................................................ 40 8.2.18 Fast Read Dual Output (3Bh) ............................................................................................. 41 8.2.19 Fast Read Dual Output with 4-Byte Address (3Ch) ............................................................ 42 8.2.20 Fast Read Quad Output (6Bh) ............................................................................................ 43 8.2.21 Fast Read Quad Output with 4-Byte Address (6Ch) ........................................................... 44 8.2.22 Fast Read Dual I/O (BBh) ................................................................................................... 45 8.2.23 Fast Read Dual I/O with 4-Byte Address (BCh) .................................................................. 46 8.2.24 Fast Read Quad I/O (EBh) ................................................................................................. 47 8.2.25 Fast Read Quad I/O with 4-Byte Address (ECh) ................................................................ 49 8.2.26 Accessing Unique ID / Parameter / OTP Pages (OTP-E=1) ............................................... 51 8.2.27 Parameter Page Data Definitions ....................................................................................... 52 ELECTRICAL CHARACTERISTICS ............................................................................................... 53 9.1 Absolute Maximum Ratings ................................................................................................ 53 9.2 Operating Ranges............................................................................................................... 53 -2- Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 10. 11. 9.3 Power-up Power-down Timing Requirements .................................................................... 54 9.4 DC Electrical Characteristics .............................................................................................. 55 9.5 AC Measurement Conditions .............................................................................................. 56 9.6 AC Electrical Characteristics .............................................................................................. 57 9.7 Serial Output Timing ........................................................................................................... 59 9.8 Serial Input Timing .............................................................................................................. 59 9.9 /HOLD Timing ..................................................................................................................... 59 9.10 /WP Timing ......................................................................................................................... 59 PACKAGE SPECIFICATIONS ........................................................................................................ 60 10.1 8-Pad WSON 8x6-mm (Package Code ZE) ....................................................................... 60 10.2 24-Ball TFBGA 8x6-mm (Package Code TB, 5x5-1 Ball Array) ......................................... 61 10.3 24-Ball TFBGA 8x6-mm (Package Code TC, 6x4 Ball Array) ............................................ 62 ORDERING INFORMATION .......................................................................................................... 63 11.1 12. Valid Part Numbers and Top Side Marking ........................................................................ 64 REVISION HISTORY ...................................................................................................................... 65 -3- W25N01GV Table of Figures Figure 1a. W25N01GV Pad Assignments, 8-pad WSON 8x6-mm (Package Code ZE) .............................. 7 Figure 1b. W25N01GV Ball Assignments, 24-ball TFBGA 8x6-mm (Package Code TB & TC) ................... 8 Figure 2. W25N01GV Flash Memory Architecture and Addressing ............................................................ 10 Figure 3. W25N01GV Flash Memory Operation Diagram .......................................................................... 11 Figure 4a. Protection Register / Status Register-1 (Address Axh) .............................................................. 14 Figure 4b. Configuration Register / Status Register-2 (Address Bxh)......................................................... 16 Figure 4c. Status Register-3 (Address Cxh) ............................................................................................... 18 Figure 5. Device Reset Instruction .............................................................................................................. 25 Figure 6. Read JEDEC ID Instruction.......................................................................................................... 26 Figure 7. Read Status Register Instruction ................................................................................................. 27 Figure 8. Write Status Register-1/2/3 Instruction ........................................................................................ 28 Figure 9. Write Enable Instruction ............................................................................................................... 29 Figure 10. Write Disable Instruction ............................................................................................................ 29 Figure 11. Bad Block Management Instruction ........................................................................................... 30 Figure 12. Read BBM Look Up Table Instruction ........................................................................................ 31 Figure 13. Last ECC Failure Page Address Instruction .............................................................................. 32 Figure 14. 128KB Block Erase Instruction .................................................................................................. 33 Figure 15. Load / Random Load Program Data Instruction ........................................................................ 34 Figure 16. Quad Load / Quad Random Load Program Data Instruction ..................................................... 35 Figure 17. Program Execute Instruction...................................................................................................... 36 Figure 18. Page Data Read Instruction ....................................................................................................... 37 Figure 19a. Read Data Instruction (Buffer Read Mode, BUF=1) ................................................................ 38 Figure 19b. Read Data Instruction (Continuous Read Mode, BUF=0) ........................................................ 38 Figure 20a. Fast Read Instruction (Buffer Read Mode, BUF=1) ................................................................. 39 Figure 20b. Fast Read Instruction (Continuous Read Mode, BUF=0) ........................................................ 39 Figure 21a. Fast Read with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) ................................ 40 Figure 21b. Fast Read with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) ....................... 40 Figure 22a. Fast Read Dual Output Instruction (Buffer Read Mode, BUF=1) ............................................. 41 Figure 22b. Fast Read Dual Output Instruction (Continuous Read Mode, BUF=0) .................................... 41 Figure 23a. Fast Read Dual Output with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) ............ 42 Figure 23b. Fast Read Dual Output with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) ... 42 Figure 24a. Fast Read Quad Output Instruction (Buffer Read Mode, BUF=1) ........................................... 43 Figure 24b. Fast Read Quad Output Instruction (Continuous Read Mode, BUF=0) ................................... 43 Figure 25a. Fast Read Quad Output with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) .......... 44 Figure 25b. Fast Read Quad Output with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) .. 44 -4- Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV Figure 26a. Fast Read Dual I/O Instruction (Buffer Read Mode, BUF=1) ................................................... 45 Figure 26b. Fast Read Dual I/O Instruction (Continuous Read Mode, BUF=0) .......................................... 45 Figure 27a. Fast Read Dual I/O with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) .................. 46 Figure 27b. Fast Read Dual I/O with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) ......... 46 Figure 28a. Fast Read Quad I/O Instruction (Buffer Read Mode, BUF=1) ................................................. 47 Figure 28b. Fast Read Quad I/O Instruction (Continuous Read Mode, BUF=0) ......................................... 48 Figure 29a. Fast Read Quad I/O with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) ................ 49 Figure 29b. Fast Read Quad I/O with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) ........ 50 Figure 30a. Power-up Timing and Voltage Levels ...................................................................................... 54 Figure 30b. Power-up, Power-Down Requirement...................................................................................... 54 Figure 31. AC Measurement I/O Waveform................................................................................................ 56 -5- W25N01GV 1. GENERAL DESCRIPTIONS The W25N01GV (1G-bit) Serial SLC NAND Flash Memory provides a storage solution for systems with limited space, pins and power. The W25N SpiFlash family incorporates the popular SPI interface and the traditional large NAND non-volatile memory space. They are ideal for code shadowing to RAM, executing code directly from Dual/Quad SPI (XIP) and storing voice, text and data. The device operates on a single 2.7V to 3.6V power supply with current consumption as low as 25mA active and 10A for standby. All W25N SpiFlash family devices are offered in space-saving packages which were impossible to use in the past for the typical NAND flash memory. The W25N01GV 1G-bit memory array is organized into 65,536 programmable pages of 2,048-bytes each. The entire page can be programmed at one time using the data from the 2,048-Byte internal buffer. Pages can be erased in groups of 64 (128KB block erase). The W25N01GV has 1,024 erasable blocks. The W25N01GV supports the standard Serial Peripheral Interface (SPI), Dual/Quad I/O SPI: Serial Clock, Chip Select, Serial Data I/O0 (DI), I/O1 (DO), I/O2 (/WP), and I/O3 (/HOLD). SPI clock frequencies of up to 104MHz are supported allowing equivalent clock rates of 208MHz (104MHz x 2) for Dual I/O and 416MHz (104MHz x 4) for Quad I/O when using the Fast Read Dual/Quad I/O instructions. The W25N01GV provides a new Continuous Read Mode that allows for efficient access to the entire memory array with a single Read command. This feature is ideal for code shadowing applications. A Hold pin, Write Protect pin and programmable write protection, provide further control flexibility. Additionally, the device supports JEDEC standard manufacturer and device ID, one 2,048-Byte Unique ID page, one 2,048-Byte parameter page and ten 2,048-Byte OTP pages. To provide better NAND flash memory manageability, user configurable internal ECC, bad block management are also available in W25N01GV. 2. FEATURES * New W25N Family of SpiFlash Memories - W25N01GV: 1G-bit / 128M-byte - Standard SPI: CLK, /CS, DI, DO, /WP, /Hold - Dual SPI: CLK, /CS, IO0, IO1, /WP, /Hold - Quad SPI: CLK, /CS, IO0, IO1, IO2, IO3 - Compatible SPI serial flash commands * Highest Performance Serial NAND Flash - 104MHz Standard/Dual/Quad SPI clocks - 208/416MHz equivalent Dual/Quad SPI - 50MB/S continuous data transfer rate - Fast Program/Erase performance - More than 100,000 erase/program cycles - More than 10-year data retention * Efficient "Continuous Read Mode"(1) - Alternative method to the Buffer Read Mode - No need to issue "Page Data Read" between Read commands - Allows direct read access to the entire array * Flexible Architecture with 128KB blocks - Uniform 128K-Byte Block Erase - Flexible page data load methods * Advanced Features - On chip 1-Bit ECC for memory array - ECC status bits indicate ECC results - bad block management and LUT(2) access - Software and Hardware Write-Protect - Power Supply Lock-Down and OTP protection - 2KB Unique ID and 2KB parameter pages - Ten 2KB OTP pages(3) * Space Efficient Packaging - 8-pad WSON 8x6-mm - 24-ball TFBGA 8x6-mm - Contact Winbond for other package options Notes: 1. * Low Power, Wide Temperature Range - Single 2.7 to 3.6V supply - 25mA active, 10A standby current - -40C to +85C operating range 2. 3. -6- Only the Read command structures are different between the "Continuous Read Mode" and the "Buffer Read Mode", all other commands are identical. LUT stands for Look-Up Table. OTP pages can only be programmed. Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 3. PACKAGE TYPES AND PIN CONFIGURATIONS W25N01GV is offered in an 8-pad WSON 8x6-mm (package code ZE), and two 24-ball 8x6-mm TFBGA (package code TB & TC) packages as shown in Figure 1a-b respectively. Package diagrams and dimensions are illustrated at the end of this datasheet. 3.1 Pad Configuration WSON 8x6-mm Top View /CS 1 8 VCC DO (IO1) 2 7 /HOLD (IO3) /WP (IO2) 3 6 CLK GND 4 5 DI (IO0) Figure 1a. W25N01GV Pad Assignments, 8-pad WSON 8x6-mm (Package Code ZE) 3.2 Pad Description WSON 8x6-mm PAD NO. PAD NAME I/O FUNCTION 1 /CS I 2 DO (IO1) I/O Data Output (Data Input Output 1)(1) 3 /WP (IO2) I/O Write Protect Input ( Data Input Output 2)(2) 4 GND 5 DI (IO0) I/O 6 CLK I 7 /HOLD (IO3) I/O 8 VCC Chip Select Input Ground Data Input (Data Input Output 0)(1) Serial Clock Input Hold Input (Data Input Output 3)(2) Power Supply Notes: 1. IO0 and IO1 are used for Standard and Dual SPI instructions 2. IO0 - IO3 are used for Quad SPI instructions, /WP & /HOLD functions are only available for Standard/Dual SPI. -7- W25N01GV 3.3 Ball Configuration TFBGA 8x6-mm (5x5 or 6x4 Ball Array) Figure 1b. W25N01GV Ball Assignments, 24-ball TFBGA 8x6-mm (Package Code TB & TC) 3.4 Ball Description TFBGA 8x6-mm BALL NO. PIN NAME I/O FUNCTION B2 CLK I B3 GND Ground B4 VCC Power Supply C2 /CS I C4 /WP (IO2) I/O Write Protect Input (Data Input Output 2)(2) D2 DO (IO1) I/O Data Output (Data Input Output 1)(1) D3 DI (IO0) I/O Data Input (Data Input Output 0)(1) D4 /HOLD (IO3) I/O Hold Input (Data Input Output 3)(2) Multiple NC Serial Clock Input Chip Select Input No Connect Notes: 1. IO0 and IO1 are used for Standard and Dual SPI instructions 2. IO0 - IO3 are used for Quad SPI instructions, /WP & /HOLD functions are only available for Standard/Dual SPI. -8- Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 4. PIN DESCRIPTIONS 4.1 Chip Select (/CS) The SPI Chip Select (/CS) pin enables and disables device operation. When /CS is high the device is deselected and the Serial Data Output (DO, or IO0, IO1, IO2, IO3) pins are at high impedance. When deselected, the devices power consumption will be at standby levels unless an internal erase, program or write status register cycle is in progress. When /CS is brought low the device will be selected, power consumption will increase to active levels and instructions can be written to and data read from the device. After power-up, /CS must transition from high to low before a new instruction will be accepted. The /CS input must track the VCC supply level at power-up and power-down (see "Write Protection" and Figure 30b). If needed, a pull-up resistor on the /CS pin can be used to accomplish this. 4.2 Serial Data Input, Output and IOs (DI, DO and IO0, IO1, IO2, IO3) The W25N01GV supports standard SPI, Dual SPI and Quad SPI operation. Standard SPI instructions use the unidirectional DI (input) pin to serially write instructions, addresses or data to the device on the rising edge of the Serial Clock (CLK) input pin. Standard SPI also uses the unidirectional DO (output) to read data or status from the device on the falling edge of CLK. Dual and Quad SPI instructions use the bidirectional IO pins to serially write instructions, addresses or data to the device on the rising edge of CLK and read data or status from the device on the falling edge of CLK. 4.3 Write Protect (/WP) The Write Protect (/WP) pin can be used to prevent the Status Register from being written. Used in conjunction with the Status Register's Block Protect bits BP[3:0] and Status Register Protect SRP bits SRP[1:0], a portion as small as 256K-Byte (2x128KB blocks) or up to the entire memory array can be hardware protected. The WP-E bit in the Protection Register (SR-1) controls the functions of the /WP pin. When WP-E=0, the device is in the Software Protection mode that only SR-1 can be protected. The /WP pin functions as a data I/O pin for the Quad SPI operations, as well as an active low input pin for the Write Protection function for SR-1. Refer to section 7.1.3 for detail information. When WP-E=1, the device is in the Hardware Protection mode that /WP becomes a dedicated active low input pin for the Write Protection of the entire device. If /WP is tied to GND, all "Write/Program/Erase" functions are disabled. The entire device (including all registers, memory array, OTP pages) will become read-only. Quad SPI read operations are also disabled when WP-E is set to 1. 4.4 HOLD (/HOLD) During Standard and Dual SPI operations, the /HOLD pin allows the device to be paused while it is actively selected. When /HOLD is brought low, while /CS is low, the DO pin will be at high impedance and signals on the DI and CLK pins will be ignored (don't care). When /HOLD is brought high, device operation can resume. The /HOLD function can be useful when multiple devices are sharing the same SPI signals. The /HOLD pin is active low. When a Quad SPI Read/Buffer Load command is issued, /HOLD pin will become a data I/O pin for the Quad operations and no HOLD function is available until the current Quad operation finishes. 4.5 Serial Clock (CLK) The SPI Serial Clock Input (CLK) pin provides the timing for serial input and output operations. ("See SPI Operations") -9- W25N01GV 5. BLOCK DIAGRAM 1,024 Blocks (65,536 Pages) Address Bits SpiFlash (up to 128MBit) SpiFlash (up to 32GBit) Serial NAND (1GBit) 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Byte Address (0255 Byte) X X X X X X X X 64KB Block Addr (256 Blocks) Page Address (256 Pages) 64KB Block Address Page Address (256 Pages) Byte Address (0255 Byte) 128KB Block Addr (1024 Blocks) Page Addr (64 Pages) Ext Byte Address (02047 Byte) X X X X Main Memory Array (2,048-Byte) ECC Protected Page Structure (2,112-Byte) Sector 0 512-Byte Sector 1 512-Byte Sector 2 512-Byte Column Address 000h -- 1FFh 200h -- 3FFh 400h -- 5FFh Sector 3 512-Byte Byte Bad Block User Data Definition Marker II Byte Address 0 1 2 3 Spare Area (64-Byte) Spare 0 16-Byte Spare 1 16-Byte Spare 3 16-Byte 600h -- 7FFh 800h -- 80Fh 810h -- 81Fh 820h -- 82Fh 830h -- 83Fh User Data I 4 Spare 2 16-Byte 5 No ECC Protection 6 ECC for Sector 0 7 8 9 A B ECC for Spare C ECC Protected D E F ECC for Byte 4 to Byte D Figure 2. W25N01GV Flash Memory Architecture and Addressing - 10 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 6. FUNCTIONAL DESCRIPTIONS 6.1 Device Operation Flow Power Up (default BUF=1, ECC-E=1) Initialization & Default Page Load (00) ~500us Read page 00? Y N Load Page xx tRD ~50us Start "Buffer Read" with column address (Page 00 or Page xx) Set BUF=0 Load Page yy tRD ~50us Start "Continuous Read" from column 0 (Page yy) Figure 3. W25N01GV Flash Memory Operation Diagram 6.1.1 Standard SPI Instructions The W25N01GV is accessed through an SPI compatible bus consisting of four signals: Serial Clock (CLK), Chip Select (/CS), Serial Data Input (DI) and Serial Data Output (DO). Standard SPI instructions use the DI input pin to serially write instructions, addresses or data to the device on the rising edge of CLK. The DO output pin is used to read data or status from the device on the falling edge of CLK. SPI bus operation Mode 0 (0,0) and 3 (1,1) are supported. The primary difference between Mode 0 and Mode 3 concerns the normal state of the CLK signal when the SPI bus master is in standby and data is not being transferred to the Serial Flash. For Mode 0, the CLK signal is normally low on the falling and rising edges of /CS. For Mode 3, the CLK signal is normally high on the falling and rising edges of /CS. 6.1.2 Dual SPI Instructions The W25N01GV supports Dual SPI operation when using instructions such as "Fast Read Dual Output (3Bh)" and "Fast Read Dual I/O (BBh)". These instructions allow data to be transferred to or from the - 11 - W25N01GV device at two to three times the rate of ordinary Serial Flash devices. The Dual SPI Read instructions are ideal for quickly downloading code to RAM upon power-up (code-shadowing) or for executing non-speedcritical code directly from the SPI bus (XIP). When using Dual SPI instructions, the DI and DO pins become bidirectional I/O pins: IO0 and IO1. 6.1.3 Quad SPI Instructions The W25N01GV supports Quad SPI operation when using instructions such as "Fast Read Quad Output (6Bh)", "Fast Read Quad I/O (EBh)" and "Quad Program Data Load (32h/34h)". These instructions allow data to be transferred to or from the device four to six times the rate of ordinary Serial Flash. The Quad Read instructions offer a significant improvement in continuous and random access transfer rates allowing fast code-shadowing to RAM or execution directly from the SPI bus (XIP). When using Quad SPI instructions the DI and DO pins become bidirectional IO0 and IO1, and the /WP and /HOLD pins become IO2 and IO3 respectively. 6.1.4 Hold Function For Standard SPI and Dual SPI operations, the /HOLD signal allows the W25N01GV operation to be paused while it is actively selected (when /CS is low). The /HOLD function may be useful in cases where the SPI data and clock signals are shared with other devices. For example, consider if the page buffer was only partially written when a priority interrupt requires use of the SPI bus. In this case the /HOLD function can save the state of the instruction and the data in the buffer so programming can resume where it left off once the bus is available again. The /HOLD function is only available for standard SPI and Dual SPI operation, not during Quad SPI. When a Quad SPI command is issued, /HOLD pin will act as a dedicated IO pin (IO3). To initiate a /HOLD condition, the device must be selected with /CS low. A /HOLD condition will activate on the falling edge of the /HOLD signal if the CLK signal is already low. If the CLK is not already low the /HOLD condition will activate after the next falling edge of CLK. The /HOLD condition will terminate on the rising edge of the /HOLD signal if the CLK signal is already low. If the CLK is not already low the /HOLD condition will terminate after the next falling edge of CLK. During a /HOLD condition, the Serial Data Output (DO) is high impedance, and Serial Data Input (DI) and Serial Clock (CLK) are ignored. The Chip Select (/CS) signal should be kept active (low) for the full duration of the /HOLD operation to avoid resetting the internal logic state of the device. - 12 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 6.2 Write Protection Applications that use non-volatile memory must take into consideration the possibility of noise and other adverse system conditions that may compromise data integrity. To address this concern, the W25N01GV provides several means to protect the data from inadvertent writes. * * * * * * Device resets when VCC is below threshold Write enable/disable instructions and automatic write disable after erase or program Software and Hardware (/WP pin) write protection using Protection Register (SR-1) Lock Down write protection for Protection Register (SR-1) until the next power-up One Time Program (OTP) write protection for memory array using Protection Register (SR-1) Hardware write protection using /WP pin when WP-E is set to 1 Upon power-up or at power-down, the W25N01GV will maintain a reset condition while VCC is below the threshold value of VWI, (See Power-up Timing and Voltage Levels and Figure 30a). While reset, all operations are disabled and no instructions are recognized. During power-up and after the VCC voltage exceeds VWI, all program and erase related instructions are further disabled for a time delay of tPUW . This includes the Write Enable, Program Execute, Block Erase and the Write Status Register instructions. Note that the chip select pin (/CS) must track the VCC supply level at power-up until the VCC-min level and tVSL time delay is reached, and it must also track the VCC supply level at power-down to prevent adverse command sequence. If needed a pull-up resister on /CS can be used to accomplish this. After power-up the device is automatically placed in a write-disabled state with the Status Register Write Enable Latch (WEL) set to a 0. A Write Enable instruction must be issued before a Program Execute or Block Erase instruction will be accepted. After completing a program or erase instruction the Write Enable Latch (WEL) is automatically cleared to a write-disabled state of 0. Software controlled write protection is facilitated using the Write Status Register instruction and setting the Status Register Protect (SRP0, SRP1) and Block Protect (TB, BP[3:0]) bits. These settings allow a portion or the entire memory array to be configured as read only. Used in conjunction with the Write Protect (/WP) pin, changes to the Status Register can be enabled or disabled under hardware control. See Protection Register section for further information. The WP-E bit in Protection Register (SR-1) is used to enable the hardware protection. When WP-E is set to 1, bringing /WP low in the system will block any Write/Program/Erase command to the W25N01GV, the device will become read-only. The Quad SPI operations are also disabled when WP-E is set to 1. - 13 - W25N01GV 7. PROTECTION, CONFIGURATION AND STATUS REGISTERS Three Status Registers are provided for W25N01GV: Protection Register (SR-1), Configuration Register (SR-2) & Status Register (SR-3). Each register is accessed by Read Status Register and Write Status Register commands combined with 1-Byte Register Address respectively. The Read Status Register instruction (05h / 0Fh) can be used to provide status on the availability of the flash memory array, whether the device is write enabled or disabled, the state of write protection, Read modes, Protection Register/OTP area lock status, Erase/Program results, ECC usage/status. The Write Status Register instruction can be used to configure the device write protection features, Software/Hardware write protection, Read modes, enable/disable ECC, Protection Register/OTP area lock. Write access to the Status Register is controlled by the state of the non-volatile Status Register Protect bits (SRP0, SRP1), the Write Enable instruction, and when WP-E is set to 1, the /WP pin. 7.1 Protection Register / Status Register-1 (Volatile Writable, OTP lockable) Figure 4a. Protection Register / Status Register-1 (Address Axh) 7.1.1 Block Protect Bits (BP3, BP2, BP1, BP0, TB) - Volatile Writable, OTP lockable The Block Protect bits (BP3, BP2, BP1, BP0 & TB) are volatile read/write bits in the status register-1 (S6, S5, S4, S3 & S2) that provide Write Protection control and status. Block Protect bits can be set using the Write Status Register Instruction. All, none or a portion of the memory array can be protected from Program and Erase instructions (see Status Register Memory Protection table). The default values for the Block Protection bits are 1 after power up to protect the entire array. If the SR1-L bit in the Configuration Register (SR-2) is set to 1, the default values will the values that are OTP locked. - 14 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 7.1.2 Write Protection Enable Bit (WP-E) - Volatile Writable, OTP lockable The Write Protection Enable bit (WP-E) is a volatile read/write bits in the status register-1 (S1). The WP-E bit, in conjunction with SRP1 & SRP0, controls the method of write protection: software protection, hardware protection, power supply lock-down or one time programmable (OTP) protection, /WP pin functionality, and Quad SPI operation enable/disable. When WP-E = 0 (default value), the device is in Software Protection mode, /WP & /HOLD pins are multiplexed as IO pins, and Quad program/read functions are enabled all the time. When WP-E is set to 1, the device is in Hardware Protection mode, all Quad functions are disabled and /WP & /HOLD pins become dedicated control input pins. 7.1.3 Status Register Protect Bits (SRP1, SRP0) - Volatile Writable, OTP lockable The Status Register Protect bits (SRP1 and SRP0) are volatile read/write bits in the status register (S0 and S7). The SRP bits control the method of write protection: software protection, hardware protection, power supply lock-down or one time programmable (OTP) protection. Software Protection (Driven by Controller, Quad Program/Read is enabled) SRP1 SRP0 WP-E /WP / IO2 Descriptions 0 0 0 X No /WP functionality /WP pin will always function as IO2 0 1 0 0 SR-1 cannot be changed (/WP = 0 during Write Status) /WP pin will function as IO2 for Quad operations 0 1 0 1 SR-1 can be changed (/WP = 1 during Write Status) /WP pin will function as IO2 for Quad operations 1 0 0 X Power Lock Down(1) SR-1 /WP pin will always function as IO2 1 1 0 X Enter OTP mode to protect SR-1 (allow SR1-L=1) /WP pin will always function as IO2 Hardware Protection (System Circuit / PCB layout, Quad Program/Read is disabled) SRP1 SRP0 WP-E /WP only Descriptions 0 X 1 VCC SR-1 can be changed 1 0 1 VCC Power Lock-Down(1) SR-1 1 1 1 VCC Enter OTP mode to protect SR-1 (allow SR1-L=1) X X 1 GND All "Write/Program/Erase" commands are blocked Entire device (SRs, Array, OTP area) is read-only Notes: 1. When SRP1, SRP0 = (1, 0), a power-down, power-up cycle will change SRP1, SRP0 to (0, 0) state. - 15 - W25N01GV 7.2 Configuration Register / Status Register-2 (Volatile Writable) Figure 4b. Configuration Register / Status Register-2 (Address Bxh) 7.2.1 One Time Program Lock Bit (OTP-L) - OTP lockable In addition to the main memory array, W25N01GV also provides an OTP area for the system to store critical data that cannot be changed once it's locked. The OTP area consists of 10 pages of 2,112-Byte each. The default data in the OTP area are FFh. Only Program command can be issued to the OTP area to change the data from "1" to "0", and data is not reversible ("0" to "1") by the Erase command. Once the correct data is programmed in and verified, the system developer can set OTP-L bit to 1, so that the entire OTP area will be locked to prevent further alteration to the data. 7.2.2 Enter OTP Access Mode Bit (OTP-E) - Volatile Writable The OTP-E bit must be set to 1 in order to use the standard Program/Read commands to access the OTP area as well as to read the Unique ID / Parameter Page information. The default value after power up or a RESET command is 0. 7.2.3 Status Register-1 Lock Bit (SR1-L) - OTP lockable The SR1-L lock bit is used to OTP lock the values in the Protection Register (SR-1). Depending on the settings in the SR-1, the device can be configured to have a portion of or up to the entire array to be writeprotected, and the setting can be OTP locked by setting SR1-L bit to 1. SR1-L bit can only be set to 1 permanently when SRP1 & SRP0 are set to (1,1), and OTP Access Mode must be entered (OTP-E=1) to execute the programming. Please refer to 8.2.26 for detailed information. - 16 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 7.2.4 ECC Enable Bit (ECC-E) - Volatile Writable W25N01GV has a built-in ECC algorithm that can be used to preserve the data integrity. Internal ECC calculation is done during page programming, and the result is stored in the extra 64-Byte area for each page. During the data read operation, ECC engine will verify the data values according to the previously stored ECC information and to make necessary corrections if needed. The verification and correction status is indicated by the ECC Status Bits. ECC function is enabled by default when power on (ECC-E=1), and it will not be reset to 0 by the Device Reset command. 7.2.5 Buffer Read / Continuous Read Mode Bit (BUF) - Volatile Writable W25N01GV provides two different modes for read operations, Buffer Read Mode (BUF=1) and Continuous Read Mode (BUF=0). Prior to any Read operation, a Page Data Read command is needed to initiate the data transfer from a specified page in the memory array to the Data Buffer. By default, after power up, the data in page 0 will be automatically loaded into the Data Buffer and the device is ready to accept any read commands. The Buffer Read Mode (BUF=1) requires a Column Address to start outputting the existing data inside the Data Buffer, and once it reaches the end of the data buffer (Byte 2,111), DO (IO1) pin will become high-Z state. The Continuous Read Mode (BUF=0) doesn't require the starting Column Address. The device will always start output the data from the first column (Byte 0) of the Data buffer, and once the end of the data buffer (Byte 2,048) is reached, the data output will continue through the next memory page. With Continuous Read Mode, it is possible to read out the entire memory array using a single read command. Please refer to respective command descriptions for the dummy cycle requirements for each read commands under different read modes. The default value of BUF bit after power up is 1. BUF bit can be written to 0 in the Status Register-2 to perform the Continuous Read operation. BUF ECC-E Read Mode (Starting from Buffer) ECC Status Data Output Structure 1 0 Buffer Read N/A 2,048 + 64 1 1 Buffer Read Page based 2,048 + 64 0 0 Continuous Read N/A 2,048 0 1 Continuous Read Operation based 2,048 - 17 - W25N01GV 7.3 Status Register-3 (Status Only) Figure 4c. Status Register-3 (Address Cxh) 7.3.1 Look-Up Table Full (LUT-F) - Status Only To facilitate the NAND flash memory bad block management, the W25N01GV is equipped with an internal Bad Block Management Look-Up-Table (BBM LUT). Up to 20 bad memory blocks may be replaced by a good memory block respectively. The addresses of the blocks are stored in the internal Look-Up Table as Logical Block Address (LBA, the bad block) & Physical Block Address (PBA, the good block). The LUT-F bit indicates whether the 20 memory block links have been fully utilized or not. The default value of LUT-F is 0, once all 20 links are used, LUT-F will become 1, and no more memory block links may be established. 7.3.2 Cumulative ECC Status (ECC-1, ECC-0) - Status Only ECC function is used in NAND flash memory to correct limited memory errors during read operations. The ECC Status Bits (ECC-1, ECC-0) should be checked after the completion of a Read operation to verify the data integrity. The ECC Status bits values are don't care if ECC-E=0. These bits will be cleared to 0 after a power cycle or a RESET command. - 18 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV ECC Status Descriptions ECC-1 ECC-0 0 0 Entire data output is successful, without any ECC correction. 0 1 Entire data output is successful, with 1~4 bit/page ECC corrections in either a single page or multiple pages. 0 Entire data output contains more than 4 bits errors only in a single page which cannot be repaired by ECC. In the Continuous Read Mode, an additional command can be used to read out the Page Address (PA) which had the errors. 1 Entire data output contains more than 4 bits errors/page in multiple pages. In the Continuous Read Mode, the additional command can only provide the last Page Address (PA) that had failures, the user cannot obtain the PAs for other failure pages. Data is not suitable to use. 1 1 Notes: 1. ECC-1,ECC-0 = (1,1) is only applicable during Continuous Read operation (BUF=0). 7.3.3 Program/Erase Failure (P-FAIL, E-FAIL) - Status Only The Program/Erase Failure Bits are used to indicate whether the internally-controlled Program/Erase operation was executed successfully or not. These bits will also be set respectively when the Program or Erase command is issued to a locked or protected memory array or OTP area. Both bits will be cleared at the beginning of the Program Execute or Block Erase instructions as well as the device RESET instruction. 7.3.4 Write Enable Latch (WEL) - Status Only Write Enable Latch (WEL) is a read only bit in the status register (S1) that is set to 1 after executing a Write Enable Instruction. The WEL status bit is cleared to 0 when the device is write disabled. A write disable state occurs upon power-up or after any of the following instructions: Write Disable, Program Execute, Block Erase, Page Data Read and Program Execute for OTP pages. 7.3.5 Erase/Program In Progress (BUSY) - Status Only BUSY is a read only bit in the status register (S0) that is set to a 1 state when the device is powering up or executing a Page Data Read, BBM Management, Program Execute, Block Erase, Program Execute for OTP area, OTP Locking or after a Continuous Read instruction. During this time the device will ignore further instructions except for the Read Status Register and Read JEDEC ID instructions. When the program, erase or write status register instruction has completed, the BUSY bit will be cleared to a 0 state indicating the device is ready for further instructions. 7.3.6 Reserved Bits - Non Functional There are a few reserved Status Register bits that may be read out as a "0" or "1". It is recommended to ignore the values of those bits. During a "Write Status Register" instruction, the Reserved Bits can be written as "0", but there will not be any effects. - 19 - W25N01GV 7.4 W25N01GV Status Register Memory Protection STATUS REGISTER(1) W25N01GV (1G-BIT / 128M-BYTE) MEMORY PROTECTION(2) PROTECTED PROTECTED PROTECTED PROTECTED PAGE ADDRESS DENSITY PORTION BLOCK(S) PA[15:0] TB BP3 BP2 BP1 BP0 X 0 0 0 0 NONE NONE NONE NONE 0 0 0 0 1 1022 & 1023 FF80h - FFFFh 256KB Upper 1/512 0 0 0 1 0 1020 thru 1023 FF00h - FFFFh 512KB Upper 1/256 0 0 0 1 1 1016 thru 1023 FE00h - FFFFh 1MB Upper 1/128 0 0 1 0 0 1008 thru 1023 FC00h - FFFFh 2MB Upper 1/64 0 0 1 0 1 992 thru 1023 F800h - FFFFh 4MB Upper 1/32 0 0 1 1 0 960 thru 1023 F000h - FFFFh 8MB Upper 1/16 0 0 1 1 1 896 thru 1023 E000h - FFFFh 16MB Upper 1/8 0 1 0 0 0 768 thru 1023 C000h - FFFFh 32MB Upper 1/4 0 1 0 0 1 512 thru 1023 8000h - FFFFh 64MB Upper 1/2 1 0 0 0 1 0&1 0000h - 007Fh 256KB Lower 1/512 1 0 0 1 0 0 thru 3 0000h - 00FFh 512KB Lower 1/256 1 0 0 1 1 0 thru 7 0000h - 01FFh 1MB Lower 1/128 1 0 1 0 0 0 thru 15 0000h - 03FFh 2MB Lower 1/64 1 0 1 0 1 0 thru 31 0000h - 07FFh 4MB Lower 1/32 1 0 1 1 0 0 thru 63 0000h - 0FFFh 8MB Lower 1/16 1 0 1 1 1 0 thru 127 0000h - 1FFFh 16MB Lower 1/8 1 1 0 0 0 0 thru 255 0000h - 3FFFh 32MB Lower 1/4 1 1 0 0 1 0 thru 511 0000h - 7FFFh 64MB Lower 1/2 X 1 0 1 X 0 thru 1023 0000h - FFFFh 128MB ALL X 1 1 X X 0 thru 1023 0000h - FFFFh 128MB ALL Notes: 1. X = don't care 2. If any Erase or Program command specifies a memory region that contains protected data portion, this command will be ignored. - 20 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8. INSTRUCTIONS The Standard/Dual/Quad SPI instruction set of the W25N01GV consists of 27 basic instructions that are fully controlled through the SPI bus (see Instruction Set Table1, 2). Instructions are initiated with the falling edge of Chip Select (/CS). The first byte of data clocked into the DI input provides the instruction code. Data on the DI input is sampled on the rising edge of clock with most significant bit (MSB) first. Instructions vary in length from a single byte to several bytes and may be followed by address bytes, data bytes, dummy bytes (don't care), and in some cases, a combination. Instructions are completed with the rising edge of edge /CS. Clock relative timing diagrams for each instruction are included in Figures 5 through 29. All read instructions can be completed after any clocked bit. However, all instructions that Write, Program or Erase must complete on a byte boundary (/CS driven high after a full 8-bits have been clocked) otherwise the instruction will be ignored. This feature further protects the device from inadvertent writes. Additionally, while the device is performing Program or Erase operation, BBM management, Page Data Read or OTP locking operations, BUSY bit will be high, and all instructions except for Read Status Register or Read JEDEC ID will be ignored until the current operation cycle has completed. 8.1 8.1.1 Device ID and Instruction Set Tables Manufacturer and Device Identification MANUFACTURER ID (MF7 - MF0) Winbond Serial Flash EFh Device ID (ID15 - ID0) W25N01GV AA21h - 21 - W25N01GV 8.1.2 Instruction Set Table 1 (Continuous Read Mode, BUF = 0)(11) Commands OpCode Byte2 Byte3 Byte4 Byte5 Device RESET FFh JEDEC ID 9Fh Dummy EFh AAh 21h Read Status Register 0Fh / 05h SR Addr S7-0 S7-0 S7-0 Write Status Register 1Fh / 01h SR Addr S7-0 Write Enable 06h Byte6 Byte7 Byte8 Byte9 S7-0 S7-0 S7-0 S7-0 Write Disable 04h BB Management (Swap Blocks) A1h LBA LBA PBA PBA Read BBM LUT A5h Dummy LBA0 LBA0 PBA0 PBA0 LBA1 LBA1 PBA1 Last ECC failure Page Address A9h Dummy PA15-8 PA7-0 Block Erase D8h Dummy PA15-8 PA7-0 02h CA15-8 CA7-0 Data-0 Data-1 Data-2 Data-3 Data-4 Data-5 84h CA15-8 CA7-0 Data-0 Data-1 Data-2 Data-3 Data-4 Data-5 32h CA15-8 CA7-0 Data-0 / 4 Data-1 / 4 Data-2 / 4 Data-3 / 4 Data-4 / 4 Data-5 / 4 34h CA15-8 CA7-0 Data-0 / 4 Data-1 / 4 Data-2 / 4 Data-3 / 4 Data-4 / 4 Data-5 / 4 Program Execute 10h Dummy PA15-8 PA7-0 Page Data Read 13h Dummy PA15-8 PA7-0 Read 03h Dummy Dummy Dummy D7-0 D7-0 D7-0 D7-0 D7-0 Fast Read 0Bh Dummy Dummy Dummy Dummy D7-0 D7-0 D7-0 D7-0 Fast Read with 4-Byte Address 0Ch Dummy Dummy Dummy Dummy Dummy D7-0 D7-0 D7-0 Fast Read Dual Output 3Bh Dummy Dummy Dummy Dummy D7-0 / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 Fast Read Dual Output with 4-Byte Address 3Ch Dummy Dummy Dummy Dummy Dummy D7-0 / 2 D7-0 / 2 D7-0 / 2 Fast Read Quad Output 6Bh Dummy Dummy Dummy Dummy D7-0 / 4 D7-0 / 4 D7-0 / 4 D7-0 / 4 Fast Read Quad Output with 4-Byte Address 6Ch Dummy Dummy Dummy Dummy Dummy D7-0 / 4 D7-0 / 4 D7-0 / 4 Fast Read Dual I/O BBh Dummy / 2 Dummy / 2 Dummy / 2 Dummy / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 Fast Read Dual I/O with 4-Byte Address BCh Dummy / 2 Dummy / 2 Dummy / 2 Dummy / 2 Dummy / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 Fast Read Quad I/O EBh Dummy / 4 Dummy / 4 Dummy / 4 Dummy / 4 Dummy / 4 Dummy / 4 D7-0 / 4 D7-0 / 4 Fast Read Quad I/O with 4-Byte Address ECh Dummy / 4 Dummy / 4 Dummy / 4 Dummy / 4 Dummy / 4 Dummy / 4 Dummy / 4 D7-0 / 4 Program Data Load (Reset Buffer) Random Program Data Load Quad Program Data Load (Reset Buffer) Random Quad Program Data Load - 22 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.1.3 Instruction Set Table 2 (Buffer Read Mode, BUF = 1, Default Mode after Power Up)(12) Commands OpCode Byte2 Byte3 Byte4 Byte5 Device RESET FFh JEDEC ID 9Fh Dummy EFh AAh 21h Read Status Register 0Fh / 05h SR Addr S7-0 S7-0 S7-0 Write Status Register 1Fh / 01h SR Addr S7-0 Write Enable 06h Byte6 Byte7 Byte8 Byte9 S7-0 S7-0 S7-0 S7-0 Write Disable 04h BB Management (Swap Blocks) A1h LBA LBA PBA PBA Read BBM LUT A5h Dummy LBA0 LBA0 PBA0 PBA0 LBA1 LBA1 PBA1 Last ECC failure Page Address A9h Dummy PA15-8 PA7-0 Block Erase D8h Dummy PA15-8 PA7-0 02h CA15-8 CA7-0 Data-0 Data-1 Data-2 Data-3 Data-4 Data-5 84h CA15-8 CA7-0 Data-0 Data-1 Data-2 Data-3 Data-4 Data-5 32h CA15-8 CA7-0 Data-0 / 4 Data-1 / 4 Data-2 / 4 Data-3 / 4 Data-4 / 4 Data-5 / 4 34h CA15-8 CA7-0 Data-0 / 4 Data-1 / 4 Data-2 / 4 Data-3 / 4 Data-4 / 4 Data-5 / 4 Program Execute 10h Dummy PA15-8 PA7-0 Page Data Read 13h Dummy PA15-8 PA7-0 Read 03h CA15-8 CA7-0 Dummy D7-0 D7-0 D7-0 D7-0 D7-0 Fast Read 0Bh CA15-8 CA7-0 Dummy D7-0 D7-0 D7-0 D7-0 D7-0 Fast Read with 4-Byte Address 0Ch CA15-8 CA7-0 Dummy Dummy Dummy D7-0 D7-0 D7-0 Fast Read Dual Output 3Bh CA15-8 CA7-0 Dummy D7-0 / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 Fast Read Dual Output with 4-Byte Address 3Ch CA15-8 CA7-0 Dummy Dummy Dummy D7-0 / 2 D7-0 / 2 D7-0 / 2 Fast Read Quad Output 6Bh CA15-8 CA7-0 Dummy D7-0 / 4 D7-0 / 4 D7-0 / 4 D7-0 / 4 D7-0 / 4 Fast Read Quad Output with 4-Byte Address 6Ch CA15-8 CA7-0 Dummy Dummy Dummy D7-0 / 4 D7-0 / 4 D7-0 / 4 Fast Read Dual I/O BBh CA15-8 / 2 CA7-0 / 2 Dummy / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 Fast Read Dual I/O with 4-Byte Address BCh CA15-8 / 2 CA7-0 / 2 Dummy / 2 Dummy / 2 Dummy / 2 D7-0 / 2 D7-0 / 2 D7-0 / 2 Fast Read Quad I/O EBh CA15-8 / 4 CA7-0 / 4 Dummy / 4 Dummy / 4 D7-0 / 4 D7-0 / 4 D7-0 / 4 D7-0 / 4 Fast Read Quad I/O with 4-Byte Address ECh CA15-8 / 4 CA7-0 / 4 Dummy / 4 Dummy / 4 Dummy / 4 Dummy / 4 Dummy / 4 D7-0 / 4 Program Data Load (Reset Buffer) Random Program Data Load Quad Program Data Load (Reset Buffer) Random Quad Program Data Load - 23 - W25N01GV Notes: 1. Output designates data output from the device. 2. Column Address (CA) only requires CA[11:0], CA[15:12] are considered as dummy bits. 3. Page Address (PA) requires 16 bits. PA[15:6] is the address for 128KB blocks (total 1,024 blocks), PA[5:0] is the address for 2KB pages (total 64 pages for each block). 4. Logical and Physical Block Address (LBA & PBA) each consists of 16 bits. LBA[9:0] & PBA[9:0] are effective Block Addresses. LBA[15:14] is used for additional information. 5. Status Register Addresses: Status Register 1 / Protection Register: Status Register 2 / Configuration Register: Status Register 3 / Status Register: 6. Dual SPI Address Input (CA15-8 / 2 and CA7-0 / 2) format: IO0 = x, x, CA10, CA8, CA6, CA4, CA2, IO1 = x, x, CA11, CA9, CA7, CA5, CA3, 7. Dual SPI Data Output (D7-0 / 2) format: IO0 = D6, D4, D2, D0, ...... IO1 = D7, D5, D3, D1, ...... 8. Quad SPI Address Input (CA15-8 / 4 and CA7-0 / 4) format: IO0 = x, CA8, CA4, CA0 IO1 = x, CA9, CA5, CA1 IO2 = x, CA10, CA6, CA2 IO3 = x, CA11, CA7, CA3 9. Quad SPI Data Input/Output (D7-0 / 4) format: IO0 = D4, D0, ...... IO1 = D5, D1, ...... IO2 = D6, D2, ...... IO3 = D7, D3, ...... Addr = Axh Addr = Bxh Addr = Cxh CA0 CA1 10. All Quad Program/Read commands are disabled when WP-E bit is set to 1 in the Protection Register. 11. For all Read operations in the Continuous Read Mode, once the /CS signal is brought to high to terminate the read operation, the device will still remain busy for ~5us (BUSY=1), and all the data inside the Data buffer will be lost and un-reliable to use. A new Page Data Read instruction must be issued to reload the correct page data into the Data Buffer. 12. For all Read operations in the Buffer Read Mode, as soon as /CS signal is brought to high to terminate the read operation, the device will be ready to accept new instructions and all the data inside the Data Buffer will remain unchanged from the previous Page Data Read instruction. - 24 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2 Instruction Descriptions 8.2.1 Device Reset (FFh) Because of the small package and the limitation on the number of pins, the W25N01GV provide a software Reset instruction instead of a dedicated RESET pin. Once the Reset instruction is accepted, any on-going internal operations will be terminated and the device will return to its default power-on state and lose all the current volatile settings, such as Volatile Status Register bits. Once the Reset command is accepted by the device, the device will take approximately tRST to reset, depending on the current operation the device is performing, tRST can be 5us~500us. During this period, no command will be accepted. Data corruption may happen if there is an on-going internal Erase or Program operation when Reset command sequence is accepted by the device. It is recommended to check the BUSY bit in Status Register before issuing the Reset command. The Device Reset (FFh) command can also be used to set the BUF bit after the device is powered up. If an FFh command is issued as the very first command (not including 9Fh/0Fh/05h), the BUF bit will be set as 1 and the device will be in the Buffer Read Mode. This FFh command will not reset the device, so there's no need to wait tRST time. /CS 0 Mode 3 CLK 1 2 3 4 5 6 Mode 0 7 Mode 3 Mode 0 Instruction (FFh) DI (IO0) High Impedance DO (IO1) Figure 5. Device Reset Instruction Register Address Protection Register Axh Configuration Register Status Register Bxh Cxh Power Up after Power Up after OTP area SR-1 locked locked Bits Shipment Default Power Up after LUT is full After Reset cmd (FFh) (not Power-Up Reset) BP[3:0], TB 1111 1 1111 1 1111 1 xxxx x (locked) No Change SRP[1:0] 00 00 00 1 1 (locked) No Change WP-E 0 0 0 x (locked) No Change OTP-L 0 0 1 0 No Change OTP-E 0 0 0 0 0 SR1-L 0 0 0 1 Clear to 0 before OTP set ECC-E 1 1 1 1 No Change BUF 1 1 1 1 No Change LUT-F 0 1 0 0 No Change ECC-1 0 0 0 0 0 ECC-0 0 0 0 0 0 P-FAIL 0 0 0 0 0 E-FAIL 0 0 0 0 0 WEL 0 0 0 0 0 BUSY 1 during tRST => 0 1 during tRST => 0 1 during tRST => 0 1 during tRST => 0 Default values of the Status Registers after power up and Device Reset - 25 - 1 during tRST => 0 W25N01GV 8.2.2 Read JEDEC ID (9Fh) The Read JEDEC ID instruction is compatible with the JEDEC standard for SPI compatible serial memories that was adopted in 2003. The instruction is initiated by driving the /CS pin low and shifting the instruction code "9Fh" followed by 8 dummy clocks. The JEDEC assigned Manufacturer ID byte for Winbond (EFh) and two Device ID bytes are then shifted out on the falling edge of CLK with most significant bit (MSB) first as shown in Figure 6. For memory type and capacity values refer to Manufacturer and Device Identification table. Figure 6. Read JEDEC ID Instruction - 26 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.3 Read Status Register (0Fh / 05h) The Read Status Register instructions allow the 8-bit Status Registers to be read. The instruction is entered by driving /CS low and shifting the instruction code "0Fh or 05h" into the DI pin on the rising edge of CLK followed by an 8-bit Status Register Address. The status register bits are then shifted out on the DO pin at the falling edge of CLK with most significant bit (MSB) first as shown in Figure 7. Refer to section 7.1-3 for Status Register descriptions. The Read Status Register instruction may be used at any time, even while a Program or Erase cycle is in progress. This allows the BUSY status bit to be checked to determine when the cycle is complete and if the device can accept another instruction. The Status Register can be read continuously. The instruction is completed by driving /CS high. Figure 7. Read Status Register Instruction - 27 - W25N01GV 8.2.4 Write Status Register (1Fh / 01h) The Write Status Register instruction allows the Status Registers to be written. The writable Status Register bits include: SRP[1:0], TB, BP[3:0] and WP-E bit in Status Register-1; OTP-L, OTP-E, SR1-L, ECC-E and BUF bit in Status Register-2. All other Status Register bit locations are read-only and will not be affected by the Write Status Register instruction. To write the Status Register bits, the instruction is entered by driving /CS low, sending the instruction code "1Fh or 01h", followed by an 8-bit Status Register Address, and then writing the status register data byte as illustrated in Figure 8. Refer to section 7.1-3 for Status Register descriptions. After power up, factory default for BP[3:0], TB, ECC-E bits are 1, while other bits are 0. Figure 8. Write Status Register-1/2/3 Instruction - 28 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.5 Write Enable (06h) The Write Enable instruction (Figure 9) sets the Write Enable Latch (WEL) bit in the Status Register to a 1. The WEL bit must be set prior to every Page Program, Quad Page Program and Block Erase instruction. The Write Enable instruction is entered by driving /CS low, shifting the instruction code "06h" into the Data Input (DI) pin on the rising edge of CLK, and then driving /CS high. /CS Mode 3 CLK 0 1 2 3 4 5 6 7 Mode 0 Mode 3 Mode 0 Instruction (06h) DI (IO0) High Impedance DO (IO1) Figure 9. Write Enable Instruction 8.2.6 Write Disable (04h) The Write Disable instruction (Figure 10) resets the Write Enable Latch (WEL) bit in the Status Register to a 0. The Write Disable instruction is entered by driving /CS low, shifting the instruction code "04h" into the DI pin and then driving /CS high. Note that the WEL bit is automatically reset after Power-up and upon completion of the Page Program, Quad Page Program, Block Erase and Reset instructions. /CS Mode 3 CLK 0 1 2 3 4 5 6 Mode 0 Mode 3 Mode 0 Instruction (04h) DI (IO0) DO (IO1) 7 High Impedance Figure 10. Write Disable Instruction - 29 - W25N01GV 8.2.7 Bad Block Management (A1h) Due to large NAND memory density size and the technology limitation, NAND memory devices are allowed to be shipped to the end customers with certain amount of "Bad Blocks" found in the factory testing. Up to 2% of the memory blocks can be marked as "Bad Blocks" upon shipment, which is a maximum of 20 blocks for W25N01GV. In order to identify these bad blocks, it is recommended to scan the entire memory array for bad block markers set in the factory. A "Bad Block Marker" is a non-FFh data byte stored at Byte 0 of Page 0 for each bad block. An additional marker is also stored in the first byte of the 64-Byte spare area. W25N01GV offers a convenient method to manage the bad blocks typically found in NAND flash memory after extensive use. The "Bad Block Management" command is initiated by shifting the instruction code "A1h" into the DI pin and followed by the 16-bit "Logical Block Address" and 16-bit "Physical Block Address" as illustrated in Figure 11. The logical block address is the address for the "bad" block that will be replaced by the "good" block indicated by the physical block address. Once a Bad Block Management command is successfully executed, the specified LBA-PBA link will be added to the internal Look Up Table (LUT). Up to 20 links can be established in the non-volatile LUT. If all 20 links have been written, the LUT-F bit in the Status Register will become a 1, and no more LBA-PBA links can be established. Therefore, prior to issuing the Bad Block Management command, the LUT-F bit value can be checked or a "Read BBM Look Up Table" command can be issued to confirm if spare links are still available in the LUT. Figure 11. Bad Block Management Instruction - 30 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.8 Read BBM Look Up Table (A5h) The internal Look Up Table (LUT) consists of 20 Logical-Physical memory block links (from LBA0/PBA0 to LBA19/PBA19). The "Read BBM Look Up Table" command can be used to check the existing address links stored inside the LUT. The "Read BBM Look Up Table" command is initiated by shifting the instruction code "A5h" into the DI pin and followed by 8-bit dummy clocks, at the falling edge of the 16th clocks, the device will start to output the 16-bit "Logical Block Address" and the 16-bit "Physical Block Address" as illustrated in Figure 12. All block address links will be output sequentially starting from the first link (LBA0 & PBA0) in the LUT. If there are available links that are unused, the output will contain all "00h" data. The MSB bits LBA[15:14] of each link are used to indicate the status of the link. LBA[15] (Enable) LBA[14] (Invalid) 0 0 This link is available to use. 1 0 This link is enabled and it is a valid link. 1 1 This link was enabled, but it is not valid any more. 0 1 Not applicable. Descriptions Figure 12. Read BBM Look Up Table Instruction - 31 - W25N01GV 8.2.9 Last ECC Failure Page Address (A9h) To better manage the data integrity, W25N01GV implements internal ECC correction for the entire memory array. When the ECC-E bit in the Status/Configuration Register is set to 1 (also power up default), the internal ECC algorithm is enabled for all Program and Read operations. During a "Program Execute" command for a specific page, the ECC algorithm will calculate the ECC information based on the data inside the 2K-Byte data buffer and write the ECC data into the extra 64-Byte ECC area in the same physical memory page. During the Read operations, ECC information will be used to verify the data read out from the physical memory array and possible corrections can be made to limited amount of data bits that contain errors. The ECC Status Bits (ECC-1 & ECC-0) will also be set indicating the result of ECC calculation. For the "Continuous Read Mode (BUF=0)" operation, multiple pages of main array data can be read out continuously by issuing a single read command. Upon finishing the read operation, the ECC status bits should be check to verify if there's any ECC correction or un-correctable errors existed in the read out data. If ECC-1 & ECC-0 equal to (1, 0) or (1, 1), the previous read out data contain one or more pages that contain ECC un-correctable errors. The failure page address (or the last page address if it's multiple pages) can be obtained by issuing the "Last ECC failure Page Address" command as illustrated in Figure 13. The 16-bit Page Address that contains un-correctable ECC errors will be presented on the DO pin following the instruction code "A9h" and 8-bit dummy clocks on the DI pin. Figure 13. Last ECC Failure Page Address Instruction - 32 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.10 128KB Block Erase (D8h) The 128KB Block Erase instruction sets all memory within a specified block (64-Pages, 128K-Bytes) to the erased state of all 1s (FFh). A Write Enable instruction must be executed before the device will accept the Block Erase Instruction (Status Register bit WEL must equal 1). The instruction is initiated by driving the /CS pin low and shifting the instruction code "D8h" followed by 8-bit dummy clocks and the 16-bit page address. The Block Erase instruction sequence is shown in Figure 14. The /CS pin must be driven high after the eighth bit of the last byte has been latched. If this is not done the Block Erase instruction will not be executed. After /CS is driven high, the self-timed Block Erase instruction will commence for a time duration of tBE (See AC Characteristics). While the Block Erase cycle is in progress, the Read Status Register instruction may still be accessed for checking the status of the BUSY bit. The BUSY bit is a 1 during the Block Erase cycle and becomes a 0 when the cycle is finished and the device is ready to accept other instructions again. After the Block Erase cycle has finished the Write Enable Latch (WEL) bit in the Status Register is cleared to 0. The Block Erase instruction will not be executed if the addressed block is protected by the Block Protect (TB, BP2, BP1, and BP0) bits. Figure 14. 128KB Block Erase Instruction - 33 - W25N01GV 8.2.11 Load Program Data (02h) / Random Load Program Data (84h) The Program operation allows from one byte to 2,112 bytes (a page) of data to be programmed at previously erased (FFh) memory locations. A Program operation involves two steps: 1. Load the program data into the Data Buffer. 2. Issue "Program Execute" command to transfer the data from Data Buffer to the specified memory page. A Write Enable instruction must be executed before the device will accept the Load Program Data Instructions (Status Register bit WEL= 1). The "Load Program Data" or "Random Load Program Data" instruction is initiated by driving the /CS pin low then shifting the instruction code "02h" or "84h" followed by a 16-bit column address (only CA[11:0] is effective) and 8-bit dummy clocks, and at least one byte of data into the DI pin. The /CS pin must be held low for the entire length of the instruction while data is being sent to the device. If the number of data bytes sent to the device exceeds the number of data bytes in the Data Buffer, the extra data will be ignored by the device. The Load Program Data instruction sequence is shown in Figure 15. Both "Load Program Data" and "Random Load Program Data" instructions share the same command sequence. The difference is that "Load Program Data" instruction will reset the unused the data bytes in the Data Buffer to FFh value, while "Random Load Program Data" instruction will only update the data bytes that are specified by the command input sequence, the rest of the Data Buffer will remain unchanged. If internal ECC algorithm is enabled, all 2,112 bytes of data will be accepted, but the bytes designated for ECC parity bits in the extra 64 bytes section will be overwritten by the ECC calculation. If the ECC-E bit is set to a 0 to disable the internal ECC, the extra 64 bytes section can be used for external ECC purpose or other usage. /CS 0 Mode 3 CLK 7 8 9 21 22 23 24 Mode 0 Instruction DI (IO0) Column Address[15:0] 02h / 84h 15 14 13 2 1 0 7 High Impedance DO (IO1) /CS 24 30 31 32 38 39 40 Mode 3 CLK Mode 0 Data-0 DI (IO0) DO (IO1) 7 6 1 Data-1 0 7 6 1 Data-2111 0 7 0 7 6 1 0 High Impedance Figure 15. Load / Random Load Program Data Instruction - 34 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.12 Quad Load Program Data (32h) / Quad Random Load Program Data (34h) The "Quad Load Program Data" and "Quad Random Load Program Data" instructions are identical to the "Load Program Data" and "Random Load Program Data" in terms of operation sequence and functionality. The only difference is that "Quad Load" instructions will input the data bytes from all four IO pins instead of the single DI pin. This method will significantly shorten the data input time when a large amount of data needs to be loaded into the Data Buffer. The instruction sequence is illustrated in Figure 16. Both "Quad Load Program Data" and "Quad Random Load Program Data" instructions share the same command sequence. The difference is that "Quad Load Program Data" instruction will reset the unused the data bytes in the Data Buffer to FFh value, while "Quad Random Load Program Data" instruction will only update the data bytes that are specified by the command input sequence, the rest of the Data Buffer will remain unchanged. When WP-E bit in the Status Register is set to a 1, all Quad SPI instructions are disabled. /CS Mode 3 CLK 0 7 8 DO (IO1) IO2 IO3 24 25 26 Mode 3 27 Mode 0 Column Addr[15:0] Instruction DI (IO0) 23 Mode 0 32h / 34h 15 High Impedance High Impedance High Impedance 0 4 0 4 0 4 0 4 0 5 1 5 1 5 1 5 1 6 2 6 2 6 2 6 2 7 3 7 3 7 3 7 3 Data 0 Data 1 Figure 16. Quad Load / Quad Random Load Program Data Instruction - 35 - Data 2111 W25N01GV 8.2.13 Program Execute (10h) The Program Execute instruction is the second step of the Program operation. After the program data are loaded into the 2,112-Byte Data Buffer (or 2,048 bytes when ECC is enabled), the Program Execute instruction will program the Data Buffer content into the physical memory page that is specified in the instruction. The instruction is initiated by driving the /CS pin low then shifting the instruction code "10h" followed by 8-bit dummy clocks and the 16-bit Page Address into the DI pin as shown in Figure 17. After /CS is driven high to complete the instruction cycle, the self-timed Program Execute instruction will commence for a time duration of tpp (See AC Characteristics). While the Program Execute cycle is in progress, the Read Status Register instruction may still be used for checking the status of the BUSY bit. The BUSY bit is a 1 during the Program Execute cycle and becomes a 0 when the cycle is finished and the device is ready to accept other instructions again. After the Program Execute cycle has finished, the Write Enable Latch (WEL) bit in the Status Register is cleared to 0. The Program Execute instruction will not be executed if the addressed page is protected by the Block Protect (TB, BP2, BP1, and BP0) bits. Figure 17. Program Execute Instruction - 36 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.14 Page Data Read (13h) The Page Data Read instruction will transfer the data of the specified memory page into the 2,112-Byte Data Buffer. The instruction is initiated by driving the /CS pin low then shifting the instruction code "13h" followed by 8-bit dummy clocks and the 16-bit Page Address into the DI pin as shown in Figure 18. After /CS is driven high to complete the instruction cycle, the self-timed Read Page Data instruction will commence for a time duration of tRD (See AC Characteristics). While the Read Page Data cycle is in progress, the Read Status Register instruction may still be used for checking the status of the BUSY bit. The BUSY bit is a 1 during the Read Page Data cycle and becomes a 0 when the cycle is finished and the device is ready to accept other instructions again. After the 2,112 bytes of page data are loaded into the Data Buffer, several Read instructions can be issued to access the Data Buffer and read out the data. Depending on the BUF bit setting in the Status Register, either "Buffer Read Mode" or "Continuous Read Mode" may be used to accomplish the read operations. Figure 18. Page Data Read Instruction - 37 - W25N01GV 8.2.15 Read Data (03h) The Read Data instruction allows one or more data bytes to be sequentially read from the Data Buffer after executing the Read Page Data instruction. The Read Data instruction is initiated by driving the /CS pin low and then shifting the instruction code "03h" followed by the 16-bit Column Address and 8-bit dummy clocks or a 24-bit dummy clocks into the DI pin. After the address is received, the data byte of the addressed Data Buffer location will be shifted out on the DO pin at the falling edge of CLK with most significant bit (MSB) first. The address is automatically incremented to the next higher address after each byte of data is shifted out allowing for a continuous stream of data. The instruction is completed by driving /CS high. The Read Data instruction sequence is shown in Figure 19a & 19b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. Figure 19a. Read Data Instruction (Buffer Read Mode, BUF=1) Figure 19b. Read Data Instruction (Continuous Read Mode, BUF=0) - 38 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.16 Fast Read (0Bh) The Fast Read instruction allows one or more data bytes to be sequentially read from the Data Buffer after executing the Read Page Data instruction. The Fast Read instruction is initiated by driving the /CS pin low and then shifting the instruction code "0Bh" followed by the 16-bit Column Address and 8-bit dummy clocks or a 32-bit dummy clocks into the DI pin. After the address is received, the data byte of the addressed Data Buffer location will be shifted out on the DO pin at the falling edge of CLK with most significant bit (MSB) first. The address is automatically incremented to the next higher address after each byte of data is shifted out allowing for a continuous stream of data. The instruction is completed by driving /CS high. The Fast Read instruction sequence is shown in Figure 20a & 20b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. Figure 20a. Fast Read Instruction (Buffer Read Mode, BUF=1) Figure 20b. Fast Read Instruction (Continuous Read Mode, BUF=0) - 39 - W25N01GV 8.2.17 Fast Read with 4-Byte Address (0Ch) The Fast Read instruction allows one or more data bytes to be sequentially read from the Data Buffer after executing the Read Page Data instruction. The Fast Read instruction is initiated by driving the /CS pin low and then shifting the instruction code "0Ch" followed by the 16-bit Column Address and 24-bit dummy clocks (when BUF=1) or a 40-bit dummy clocks (when BUF=0) into the DI pin. After the address is received, the data byte of the addressed Data Buffer location will be shifted out on the DO pin at the falling edge of CLK with most significant bit (MSB) first. The address is automatically incremented to the next higher address after each byte of data is shifted out allowing for a continuous stream of data. The instruction is completed by driving /CS high. The Fast Read instruction sequence is shown in Figure 21a & 21b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. /CS Mode 3 CLK 0 7 8 9 21 22 23 47 48 54 55 56 62 63 Mode 0 Instruction DI (IO0) 24 Dummy Clocks Column Address[15:0] 0Ch 15 14 13 2 1 0 Data Out 1 High Impedance DO (IO1) 7 * 6 1 Data Out 2 0 7 6 1 0 * * = MSB 7 * Figure 21a. Fast Read with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) /CS Mode 3 CLK 0 7 8 9 21 Instruction DI (IO0) 22 23 47 48 54 55 56 63 0Ch 40 Dummy Clocks 39 38 37 26 25 24 0 Data Out 1 DO (IO1) 62 Mode 0 High Impedance 7 * 6 1 * = MSB Data Out 2 0 7 6 * 1 0 7 * Figure 21b. Fast Read with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) - 40 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.18 Fast Read Dual Output (3Bh) The Fast Read Dual Output (3Bh) instruction is similar to the standard Fast Read (0Bh) instruction except that data is output on two pins; IO0 and IO1. This allows data to be transferred at twice the rate of standard SPI devices. The Fast Read Dual Output instruction sequence is shown in Figure 22a & 22b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16-bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. Figure 22a. Fast Read Dual Output Instruction (Buffer Read Mode, BUF=1) Figure 22b. Fast Read Dual Output Instruction (Continuous Read Mode, BUF=0) - 41 - W25N01GV 8.2.19 Fast Read Dual Output with 4-Byte Address (3Ch) The Fast Read Dual Output (3Ch) instruction is similar to the standard Fast Read (0Bh) instruction except that data is output on two pins; IO0 and IO1. This allows data to be transferred at twice the rate of standard SPI devices. The Fast Read Dual Output instruction sequence is shown in Figure 23a & 23b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16-bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. Figure 23a. Fast Read Dual Output with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) Figure 23b. Fast Read Dual Output with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) - 42 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.20 Fast Read Quad Output (6Bh) The Fast Read Quad Output (6Bh) instruction is similar to the Fast Read Dual Output (3Bh) instruction except that data is output on four pins, IO0, IO1, IO2, and IO3. The Fast Read Quad Output Instruction allows data to be transferred at four times the rate of standard SPI devices. The Fast Read Quad Output instruction sequence is shown in Figure 24a & 24b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16-bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. When WP-E bit in the Status Register is set to a 1, this instruction is disabled. /CS Mode 3 CLK 0 7 8 9 21 22 23 31 32 33 34 35 36 37 38 39 40 Mode 0 Instruction DI (IO0) 8 Dummy Clocks Column Address[15:0] 6Bh 15 14 13 2 1 0 High Impedance DO (IO1) High Impedance IO2 High Impedance IO3 * = MSB 4 0 4 0 4 0 4 0 4 5 1 5 1 5 1 5 1 5 6 2 6 2 6 2 6 2 6 7 3 7 3 7 3 7 3 7 *Data *Data *Data *Data *Data Out 1 Out 2 Out 3 Out 4 Out 5 Figure 24a. Fast Read Quad Output Instruction (Buffer Read Mode, BUF=1) /CS Mode 3 CLK 0 7 8 9 21 Instruction DI (IO0) DO (IO1) IO2 IO3 22 23 39 40 41 42 43 44 45 46 47 48 Mode 0 6Bh 32 Dummy Clocks 31 30 29 18 17 16 0 High Impedance High Impedance High Impedance * = MSB 4 0 4 0 4 0 4 0 4 5 1 5 1 5 1 5 1 5 6 2 6 2 6 2 6 2 6 7 3 7 3 7 3 7 3 *Data *Data *Data *Data Out 1 Out 2 Out 3 Out 4 Out 5 Figure 24b. Fast Read Quad Output Instruction (Continuous Read Mode, BUF=0) - 43 - 7 *Data W25N01GV 8.2.21 Fast Read Quad Output with 4-Byte Address (6Ch) The Fast Read Quad Output (6Ch) instruction is similar to the Fast Read Dual Output (3Bh) instruction except that data is output on four pins, IO0, IO1, IO2, and IO3. The Fast Read Quad Output Instruction allows data to be transferred at four times the rate of standard SPI devices. The Fast Read Quad Output instruction sequence is shown in Figure 25a & 25b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16-bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. When WP-E bit in the Status Register is set to a 1, this instruction is disabled. Figure 25a. Fast Read Quad Output with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) Figure 25b. Fast Read Quad Output with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) - 44 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.22 Fast Read Dual I/O (BBh) The Fast Read Dual I/O (BBh) instruction allows for improved random access while maintaining two IO pins, IO0 and IO1. It is similar to the Fast Read Dual Output (3Bh) instruction but with the capability to input the Column Address or the dummy clocks two bits per clock. This reduced instruction overhead may allow for code execution (XIP) directly from the Dual SPI in some applications. The Fast Read Quad Output instruction sequence is shown in Figure 26a & 26b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16-bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. Figure 26a. Fast Read Dual I/O Instruction (Buffer Read Mode, BUF=1) Figure 26b. Fast Read Dual I/O Instruction (Continuous Read Mode, BUF=0) - 45 - W25N01GV 8.2.23 Fast Read Dual I/O with 4-Byte Address (BCh) The Fast Read Dual I/O (BCh) instruction allows for improved random access while maintaining two IO pins, IO0 and IO1. It is similar to the Fast Read Dual Output (3Bh) instruction but with the capability to input the Column Address or the dummy clocks two bits per clock. This reduced instruction overhead may allow for code execution (XIP) directly from the Dual SPI in some applications. The Fast Read Quad Output instruction sequence is shown in Figure 27a & 27b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16-bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. Figure 27a. Fast Read Dual I/O with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) Figure 27b. Fast Read Dual I/O with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) - 46 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.24 Fast Read Quad I/O (EBh) The Fast Read Quad I/O (EBh) instruction is similar to the Fast Read Dual I/O (BBh) instruction except that address and data bits are input and output through four pins IO0, IO1, IO2 and IO3 prior to the data output. The Quad I/O dramatically reduces instruction overhead allowing faster random access for code execution (XIP) directly from the Quad SPI. The Fast Read Quad Output instruction sequence is shown in Figure 28a & 28b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16-bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. When WP-E bit in the Status Register is set to a 1, this instruction is disabled. /CS Mode 3 CLK 0 7 8 DO (IO1) IO2 IO3 10 11 12 13 14 15 16 17 18 19 20 21 22 EBh High Impedance High Impedance High Impedance 4 Dummy Clocks Column Address[15:0] Instruction DI (IO0) 9 Mode 0 12 8 4 0 X X X X 4 0 4 0 4 0 4 13 9 5 1 X X X X 5 1 5 1 5 1 5 14 10 6 2 X X X X 6 2 6 2 6 2 6 15 11 7 3 X X X X 7 3 7 3 7 3 7 * = MSB *Data *Data *Data *Data Out 1 Out 2 Out 3 Out 4 Figure 28a. Fast Read Quad I/O Instruction (Buffer Read Mode, BUF=1) - 47 - W25N01GV Figure 28b. Fast Read Quad I/O Instruction (Continuous Read Mode, BUF=0) - 48 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.25 Fast Read Quad I/O with 4-Byte Address (ECh) The Fast Read Quad I/O (ECh) instruction is similar to the Fast Read Dual I/O (BBh) instruction except that address and data bits are input and output through four pins IO0, IO1, IO2 and IO3 prior to the data output. The Quad I/O dramatically reduces instruction overhead allowing faster random access for code execution (XIP) directly from the Quad SPI. The Fast Read Quad Output instruction sequence is shown in Figure 29a & 29b. When BUF=1, the device is in the Buffer Read Mode. The data output sequence will start from the Data Buffer location specified by the 16-bit Column Address and continue to the end of the Data Buffer. Once the last byte of data is output, the output pin will become Hi-Z state. When BUF=0, the device is in the Continuous Read Mode, the data output sequence will start from the first byte of the Data Buffer and increment to the next higher address. When the end of the Data Buffer is reached, the data of the first byte of next memory page will be following and continues through the entire memory array. This allows using a single Read instruction to read out the entire memory array and is also compatible to Winbond's SpiFlash NOR flash memory command sequence. When WP-E bit in the Status Register is set to a 1, this instruction is disabled. /CS Mode 3 CLK 0 7 8 DO (IO1) IO2 IO3 10 11 12 21 22 23 24 25 25 27 28 ECh High Impedance High Impedance High Impedance 10 Dummy Clocks Column Address[15:0] Instruction DI (IO0) 9 Mode 0 12 8 4 0 X X 4 0 4 0 4 0 4 13 9 5 1 X X 5 1 5 1 5 1 5 14 10 6 2 X X 6 2 6 2 6 2 6 15 11 7 3 X X 7 3 7 3 7 3 7 * = MSB *Data *Data *Data *Data Out 1 Out 2 Out 3 Out 4 Figure 29a. Fast Read Quad I/O with 4-Byte Address Instruction (Buffer Read Mode, BUF=1) - 49 - W25N01GV Figure 29b. Fast Read Quad I/O with 4-Byte Address Instruction (Continuous Read Mode, BUF=0) - 50 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 8.2.26 Accessing Unique ID / Parameter / OTP Pages (OTP-E=1) In addition to the main memory array, the W25N01GV is also equipped with one Unique ID Page, one Parameter Page, and ten OTP Pages. Page Address Page Name Descriptions Data Length 00h 01h 02h ... 0Bh Unique ID Page Parameter Page OTP Page [0] OTP Pages [1:8] OTP Page [9] Factory programmed, Read Only Factory programmed, Read Only Program Only, OTP lockable Program Only, OTP lockable Program Only, OTP lockable 32-Byte x 16 256-Byte x 3 2,112-Byte 2,112-Byte 2,112-Byte To access these additional data pages, the OTP-E bit in Status Register-2 must be set to "1" first. Then, Read operations can be performed on Unique ID and Parameter Pages, Read and Program operations can be performed on the OTP pages if it's not already locked. To return to the main memory array operation, OTP-E bit needs to be to set to 0. Read Operations A "Page Data Read" command must be issued followed by a specific page address shown in the table above to load the page data into the main Data Buffer. After the device finishes the data loading (BUSY=0), all Read commands may be used to read the Data Buffer starting from any specified Column Address. Please note all Read commands must now follow the "Buffer Read Mode" command structure (CA[15:0], number of dummy clocks) regardless the previous BUF bit setting. ECC can also be enabled for the OTP page read operations to ensure the data integrity. Program and OTP Lock Operations OTP pages provide the additional space (2K-Byte x 10) to store important data or security information that can be locked to prevent further modification in the field. These OTP pages are in an erased state set in the factory, and can only be programmed (change data from "1" to "0") until being locked by OTP-L bit in the Configuration/Status Register-2. OTP-E must be first set to "1" to enable the access to these OTP pages, then the program data must be loaded into the main Data Buffer using any "Program Data Load" commands. The "Program Execute" command followed by a specific OTP Page Address is used to initiate the data transfer from the Data Buffer to the OTP page. When ECC is enabled, ECC calculation will be performed during "Program Execute", and the ECC information will be stored into the 64-Byte spare area. Once the OTP pages are correctly programmed, OTP-L bit can be used to permanently lock these pages so that no further modification is possible. While still in the "OTP Access Mode" (OTP-E=1), user needs to set OTP-L bit in the Configuration/Status Register-2 to "1", and issue a "Program Execute" command without any Page Address. After the device finishes the OTP lock setting (BUSY=0), the user can set OTP-E to "0" to return to the main memory array operation. SR1-L OTP Lock Operation The Protection/Status Register-1 contains protection bits that can be set to protect either a portion or the entire memory array from being Programmed/Erased or set the device to either Software Write Protection (WP-E=0) or Hardware Write Protection (WP-E=1). Once the BP[3:0], TB, WP-E bits are set correctly, SRP1 and SRP0 should also be set to "1"s as well to allow SR1-L bit being set to "1" to permanently lock the protection settings in the Status Register-1 (SR1). Similar to the OTP-L setting procedure above, in order to set SR1-L lock bit, the device must enter the "OTP Access Mode" (OTP-E=1) first, and SR1-L bit should be set to "1" prior to the "Program Execute" command without any Page Address. Once SR1-L is set to "1" (BUSY=0), the user can set OTP-E to "0" to return to the main memory array operation. - 51 - W25N01GV 8.2.27 Parameter Page Data Definitions The Parameter Page contains 3 identical copies of the 256-Byte Parameter Data. The table below lists all the key data byte locations. All other unspecified byte locations have 00h data as default. Byte Number Descriptions 0~3 4~5 6~7 8~9 10~31 32~43 Parameter page signature Revision number Feature supported Optional command supported Reserved Device manufacturer 44~63 Device model 64 65~66 67~79 80~83 84~85 86~91 92~95 96~99 100 101 102 103~104 105~106 107 108~109 110 111 112 113 114 115~127 128 129~132 133~134 135~136 137~138 139~163 164~165 166~253 254~255 256~511 512~767 768+ Values JEDEC manufacturer ID Date code Reserved Number of data bytes per page Number of spare bytes per page Reserved Number of pages per block Number of blocks per logical unit Number of logical units Number of address bytes Number of bits per cell Bad blocks maximum per unit Block endurance Guaranteed valid blocks at beginning of target Block endurance for guaranteed valid blocks Number of programs per page Reserved Number of ECC bits Number of plane address bits Multi-plane operation attributes Reserved I/O pin capacitance, maximum Reserved Maximum page program time (us) Maximum block erase time (us) Maximum page read time (us) Reserved Vendor specific revision number Vendor specific Integrity CRC Value of bytes 0~255 Value of bytes 0~255 Reserved 4Fh, 4Eh, 46h, 49h 00h, 00h 00h, 00h 02h, 00h All 00h 57h, 49h, 4Eh, 42h, 4Fh, 4Eh, 44h, 20h, 20h, 20h, 20h, 20h 57h, 32h, 35h, 4Eh, 30h, 31h, 47h, 56h, 20h, 20h, 20h, 20h, 20h, 20h, 20h, 20h, 20h, 20h, 20h, 20h EFh 00h, 00h All 00h 00h, 08h, 00h, 00h 40h, 00h All 00h 40h, 00h, 00h, 00h 00h, 04h, 00h, 00h 01h 00h 01h 14h, 00h 01h, 06h 01h 00h, 00h 04h 00h 00h 00h 00h All 00h 08h All 00h BCh, 02h 10h, 27h 32h, 00h All 00h 00h, 00h All 00h Set at test - 52 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 9. ELECTRICAL CHARACTERISTICS(1) 9.1 Absolute Maximum Ratings (2) PARAMETERS SYMBOL CONDITIONS RANGE UNIT -0.6 to +4.6 V Supply Voltage VCC Voltage Applied to Any Pin VIO Relative to Ground -0.6 to +4.6 V Transient Voltage on any Pin VIOT <20nS Transient Relative to Ground -2.0V to VCC+2.0V V 5 mA Short Circuit Output Crrent, IOs Storage Temperature TSTG Lead Temperature TLEAD Electrostatic Discharge Voltage VESD -65 to +150 C (3) C See Note Human Body Model(4) -2000 to +2000 V Notes: 1. Specification for W25N01GV is preliminary. See preliminary designation at the end of this document. 2. This device has been designed and tested for the specified operation ranges. Proper operation outside of these levels is not guaranteed. Exposure to absolute maximum ratings may affect device reliability. Exposure beyond absolute maximum ratings may cause permanent damage. 3. Compliant with JEDEC Standard J-STD-20C for small body Sn-Pb or Pb-free (Green) assembly and the European directive on restrictions on hazardous substances (RoHS) 2002/95/EU. 4. JEDEC Std JESD22-A114A (C1=100pF, R1=1500 ohms, R2=500 ohms). 9.2 Operating Ranges PARAMETER Supply Voltage Ambient Temperature, Operating SYMBOL CONDITIONS VCC TA Industrial - 53 - SPEC UNIT MIN MAX 2.7 3.6 V -40 +85 C W25N01GV 9.3 Power-up Power-down Timing Requirements PARAMETER SYMBOL VCC (min) to /CS Low SPEC MIN MAX tVSL(1) 50 500 Time Delay Before Write Instruction tPUW (1) 5 Write Inhibit Threshold Voltage VWI 1.0 (1) UNIT s ms 2.0 V Note: 1. These parameters are characterized only. VCC VCC(max) 0Fh/05h/9Fh/FFh are the only commands allowed. Device is fully accessible (Page 0 with ECC is ready in Buffer) /CS must track VCC VCC(min) tVSL Reset State VWI tPUW Time Figure 30a. Power-up Timing and Voltage Levels /CS must track VCC during VCC Ramp Up/Down VCC /CS Time Figure 30b. Power-up, Power-Down Requirement - 54 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 9.4 DC Electrical Characteristics SPEC PARAMETER SYMBOL CONDITIONS Input Capacitance CIN(1) VIN = 0V(1) Output Capacitance Cout(1) Input Leakage I/O Leakage Standby Current ICC1 /CS = VCC, VIN = GND or VCC Read Current ICC2 Current Page Program MIN TYP MAX UNIT 6 pF 8 pF ILI 2 A ILO 2 A 10 50 A C = 0.1 VCC / 0.9 VCC DO = Open 25 35 mA ICC3 /CS = VCC 25 35 mA Current Block Erase ICC4 /CS = VCC 25 35 mA Input Low Voltage VIL VCC x 0.3 V Input High Voltage VIH Output Low Voltage VOL IOL = 2.1mA Output High Voltage VOH IOH = -400 A VOUT = 0V(1) VCC x 0.7 V 0.4 2.4 Notes: 1. Tested on sample basis and specified through design and characterization data. TA = 25 C, VCC = 3.0V. - 55 - V V W25N01GV 9.5 AC Measurement Conditions PARAMETER SYMBOL Load Capacitance Input Rise and Fall Times Input Pulse Voltages Input Timing Reference Voltages Output Timing Reference Voltages SPEC MIN MAX UNIT CL 30 pF TR, TF 5 ns VIN 0.1 VCC to 0.9 VCC V IN 0.3 VCC to 0.7 VCC V OUT 0.5 VCC V Input and Output Timing Reference Levels Input Levels 0.9 VCC 0.5 VCC 0.1 VCC Figure 31. AC Measurement I/O Waveform - 56 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 9.6 AC Electrical Characteristics(3) DESCRIPTION SYMBOL ALT FR fC1 Clock frequency for all instructions Clock High, Low Time for all instructions SPEC MIN D.C. TYP MAX 104 UNIT MHz tCLH, tCLL(1) 4 ns Clock Rise Time peak to peak tCLCH(2) 0.1 V/ns Clock Fall Time peak to peak tCHCL(2) 0.1 V/ns 5 ns 5 ns /CS Active Setup Time relative to CLK tSLCH /CS Not Active Hold Time relative to CLK tCHSL Data In Setup Time tDVCH tDSU 2 ns Data In Hold Time tCHDX tDH 3 ns /CS Active Hold Time relative to CLK tCHSH 3 ns /CS Not Active Setup Time relative to CLK tSHCH 3 ns /CS Deselect Time (for Array Read AE Array Read) tSHSL1 tCSH 10 ns /CS Deselect Time (for Erase, Program or Read Status Registers AE Read Status Registers) tSHSL2 tCSH 50 ns tSHQZ(2) tDIS 7 ns Clock Low to Output Valid tCLQV tV 7 ns Output Hold Time tCLQX tHO /HOLD Active Setup Time relative to CLK /HOLD Active Hold Time relative to CLK Output Disable Time tCSS 2 ns tHLCH 5 ns tCHHH 5 ns Continued - next page - 57 - W25N01GV AC Electrical Characteristics (cont'd) SPEC DESCRIPTION SYMBOL ALT MIN TYP MAX UNIT /HOLD Not Active Setup Time relative to CLK tHHCH 5 ns /HOLD Not Active Hold Time relative to CLK tCHHL 5 ns /HOLD to Output Low-Z tHHQX(2) tLZ 7 ns /HOLD to Output High-Z tHLQZ(2) tHZ 12 ns Write Protect Setup Time Before /CS Low tWHSL 20 ns Write Protect Hold Time After /CS High tSHWL 100 ns Status Register Write Time tW 50 ns tRST(2) 5/10/500 s Read Page Data Time (ECC disabled) tRD1 25 s Read Page Data Time (ECC enabled) tRD2 50 s /CS High to next Instruction after Reset during Page Data Read / Program Execute / Block Erase Page Program, OTP Lock, BBM Management Time tPP 250 700 us Block Erase Time tBE 2 10 ms Number of partial page programs NoP 4 times Notes: 1. 2. 3. Clock high + Clock low must be less than or equal to 1/fC. Value guaranteed by design and/or characterization, not 100% tested in production. Tested on sample basis and specified through design and characterization data. TA = 25 C, VCC = 3.0V. - 58 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 9.7 Serial Output Timing /CS tCLH CLK 9.8 tCLQV tCLQX tCLQX IO output tCLL tCLQV MSB OUT tSHQZ LSB OUT Serial Input Timing /CS tSHSL tCHSL tSLCH tCHSH tSHCH CLK tDVCH IO input 9.9 tCHDX tCLCH MSB IN tCHCL LSB IN /HOLD Timing /CS tHLCH tCHHL tHHCH CLK tCHHH /HOLD tHLQZ tHHQX IO output IO input 9.10 /WP Timing /CS tWHSL tSHWL /WP CLK IO input Write Status Register is allowed - 59 - Write Status Register is not allowed W25N01GV 10. PACKAGE SPECIFICATIONS 10.1 8-Pad WSON 8x6-mm (Package Code ZE) - 60 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 10.2 24-Ball TFBGA 8x6-mm (Package Code TB, 5x5-1 Ball Array) Note: Ball land: 0.45mm. Ball Opening: 0.35mm PCB ball land suggested <= 0.35mm Min Millimeters Nom Max Min Inches Nom A --- --- 1.20 --- --- 0.047 A1 0.25 0.30 0.35 0.010 0.012 0.014 Symbol Max A2 --- 0.85 --- --- 0.033 --- b 0.35 0.40 0.45 0.014 0.016 0.018 D 7.90 8.00 8.10 0.311 0.315 0.319 6.10 0.232 D1 E E1 4.00 BSC 5.90 6.00 0.157 BSC 4.00 BSC 0.236 0.157 BSC SE 1.00 TYP 0.039 TYP SD 1.00 TYP 0.039 TYP e 1.00 BSC 0.039 BSC - 61 - 0.240 W25N01GV 10.3 24-Ball TFBGA 8x6-mm (Package Code TC, 6x4 Ball Array) Note: Ball land: 0.45mm. Ball Opening: 0.35mm PCB ball land suggested <= 0.35mm Min Millimeters Nom Max Min Inches Nom Max A --- --- 1.20 --- --- 0.047 A1 0.25 0.30 0.35 0.010 0.012 0.014 b 0.35 0.40 0.45 0.014 0.016 0.018 D 7.95 8.00 8.05 0.313 0.315 0.317 Symbol D1 E 5.00 BSC 5.95 6.00 0.197 BSC 6.05 0.234 0.236 E1 3.00 BSC 0.118 BSC e 1.00 BSC 0.039 BSC - 62 - 0.238 Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 11. ORDERING INFORMATION W(1) 25N 01G V xx I(1) W = Winbond 25N = Serial SLC NAND Memory 01G = 1G-bit V = 2.7V to 3.6V ZE = 8-pad WSON 8x6mm TB = 24-ball TFBGA 8x6-mm (5x5 ball array) I = TC = 24-ball TFBGA 8x6-mm (6x4 ball array) Industrial (-40C to +85C) (2,3) G = Green Package (Lead-free, RoHS Compliant, Halogen-free (TBBA), Antimony-Oxide-free Sb2O3) Notes: 1. The "W" prefix and the Temperature designator "I" is not included on the part marking. 2. Standard bulk shipments are in Tube (shape E). Please specify alternate packing method, such as Tape and Reel (shape T) or Tray (shape S), when placing orders. 3. For shipments with special order options, please specify when placing orders. - 63 - W25N01GV 11.1 Valid Part Numbers and Top Side Marking The following table provides the valid part numbers for the W25N01GV SpiFlash Memory. Please contact Winbond for specific availability by density and package type. Winbond SpiFlash memories use a 12-digit Product Number for ordering. However, due to limited space, the Top Side Marking on all packages uses an abbreviated 9-digit number. Industrial Temperature: PACKAGE TYPE DENSITY PRODUCT NUMBER TOP SIDE MARKING ZE WSON-8 8x6mm 1G-bit W25N01GVZEIG 25N01GVEG TB TFBGA-24 8x6mm (5x5-1 Ball Array) 1G-bit W25N01GVTBIG 25N01GVBG TC TFBGA-24 8x6mm (6x4 Ball Array) 1G-bit W25N01GVTCIG 25N01GVCG - 64 - Publication Release Date: December 13, 2014 Preliminary - Revision C W25N01GV 12. REVISION HISTORY VERSION DATE PAGE DESCRIPTION A 06/13/2013 New Create Preliminary B 11/26/2013 Overall updates 63, 65, 66 C 12/13/2014 11 17, 26 Removed SOIC-16 package, updated order information Updated Figure.3 for device operation Changed BUF bit default value to 1 after power up Preliminary Designation The "Preliminary" designation on a Winbond datasheet indicates that the product is not fully characterized. The specifications are subject to change and are not guaranteed. Winbond or an authorized sales representative should be consulted for current information before using this product. Trademarks Winbond and SpiFlash are trademarks of Winbond Electronics Corporation. All other marks are the property of their respective owner. Important Notice Winbond products are not designed, intended, authorized or warranted for use as components in systems or equipment intended for surgical implantation, atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, or for other applications intended to support or sustain life. Furthermore, Winbond products are not intended for applications wherein failure of Winbond products could result or lead to a situation wherein personal injury, death or severe property or environmental damage could occur. Winbond customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Winbond for any damages resulting from such improper use or sales. Information in this document is provided solely in connection with Winbond products. Winbond reserves the right to make changes, corrections, modifications or improvements to this document and the products and services described herein at any time, without notice. - 65 -