Retroreflective area sensor RLG28-55/40a/115b/136 Dimensions 54.4 14.8 8 25.8 10.5 60 88 90 62 12 14 6 o 5.2 -0.2 5.5 11 5.2 -0.2 o 6.5 10 L D T 9.8 Model Number RLG28-55/40a/115b/136 Retroreflective area sensor with 300 mm fixed cable and 4-pin, M12 x 1 connector Electrical connection Option: 1 +UB * Retro-reflective area sensor with 6 light beams in standard photoelectricsensor enclosure 2 Q2 * Connection compatibly replaces single beam photoelectric sensor 3 0V 4 Q1 Features * Reliable detection of the front edge of the object irrespective of its shape and position * Constant object detection from 12 mm within the entire detection area * Reliable detection of all surfaces irrespective of the object texture = Light on = Dark on Pinout * Switches when contrast difference 10% 1 3 Product information Indicators/operating means 2 3 2 5 1 Operating display green 2 Signal display T 1 3 TEACH-IN button D The RLG28 retro-reflective area sensor contains several transmitters and receivers in one housing and with a reflector positioned opposite forms a 60 mm detection area over a sensing range of 4 m. When the light beams are interrupted by an object, the switching function is triggered. The smallest detectable object size is 12 mm. The RLG28 switches at a 10% contrast difference with a response time of 1 ms. An intelligent gain control compensates for effects such as dirt, misalignment, and temperature. 4 2 4 Light/dark switch yellow L Release date: 2015-02-18 11:23 Date of issue: 2015-02-18 217956_eng.xml * Bright, highly visible transmitter beams, guarantee convenient alignment of the sensor 5 Emitter 4 Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com 6 Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 6 Receiver 1 Retroreflective area sensor RLG28-55/40a/115b/136 Technical data Accessories 0 ... 4 m H60 reflector: 0.4 ... 4 m , H85-2 reflector: 0.2 ... 4 m , Foil reflector OFR-100/100: 0.4 ... 3 m 5.6 m typical 60 mm , Object has to cover the refelector completely in one dimension H60 reflector , H85-2 reflector , Foil reflector OFR-100/100 LED modulated visible red light , 625 nm yes 6 approx. 220 mm at detection range 4 m +/- 2.5 5000 Lux 12 mm Threshold detection range Sensing range Reference target Light source Light type Polarization filter Number of beams Diameter of the light spot Angle of divergence Ambient light limit Resolution Functional safety related parameters MTTFd Mission Time (TM) Diagnostic Coverage (DC) Indicators/operating means Operation indicator Control elements Electrical specifications Operating voltage UB Ripple No-load supply current I0 Output Switching type Signal output Switching voltage Switching current Voltage drop Switching frequency Response time Ambient conditions Ambient temperature Storage temperature Mechanical specifications Degree of protection Connection Material Housing Optical face Mass Ud f OMH-07 Mounting aid for round steel o 12 mm or sheet 1.5 mm ... 3 mm OMH-21 Mounting bracket OMH-RLK29-HW Mounting bracket for rear wall mounting OMH-K01 dove tail mounting clamp REF-H60 Reflector, rectangular 40.5 mm x 60 mm, mounting holes 310 a 20 a 0% LED green, statically lit Power on Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) short-circuit : LED green flashing (approx. 4 Hz) 2 LEDs yellow, light up when light beam is free, flash when falling short of the stability control, off when light beam is interrupted Teach-In : LED yellow/green; equiphase flashing; 2,5 Hz Changeover signal tracking: LED yellow, 1 Hz flashing / 2x flashing rotary switch for light/dark , Teach-In key Function indicator OMH-05 Mounting aid for round steel o 12 mm or sheet 1.5 mm ... 3 mm REF-H85-2 Reflector, rectangular 84.5 mm x 84.5 mm, mounting holes V1-G-2M-PVC Female cordset, M12, 4-pin, PVC cable V1-G-2M-PUR Female cordset, M12, 4-pin, PUR cable V1-W-2M-PUR Female cordset, M12, 4-pin, PUR cable 12 ... 30 V DC Power from Class 2 Power Source max. 10 % max. 50 mA Additional accessories can be found in the Internet. light/dark on, switchable 2 push-pull (4 in 1) outputs, complementary, short-circuit proof, reverse polarity protected max. 30 V DC max. 100 mA 2.5 V DC 230 Hz 1 ms -30 ... 60 C (-22 ... 140 F) -10 ... 40 C (14 ... 104 F) for inactive signal tracking -40 ... 70 C (-40 ... 158 F) IP67 300 mm fixed cable with M12 x 1, 4-pin connector Plastic ABS Plastic pane 100 g Compliance with standards and directives Directive conformity EMC Directive 2004/108/EC EN 60947-5-2:2007 Approvals and certificates Protection class II, rated voltage 250 V AC with pollution degree 1-2 according to IEC 60664-1 , functional insulation acc. to DIN EN 50178 UL approval cULus Listed, Class 2 Power Source CCC approval CCC approval / marking not required for products rated 36 V Notes Mounting: Ensure that the red light transmitted by the sensor fully illuminates the reflector. To ensure optimal detection, the entire 60 mm detection field must appear on the reflector. 2 Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com Release date: 2015-02-18 11:23 Date of issue: 2015-02-18 217956_eng.xml General specifications Effective detection range Reflector distance Retroreflective area sensor RLG28-55/40a/115b/136 To check this illumination, look at the reflector from over the top of the sensor housing. correct incorrect Teach-in: Press the Teach-In button > 2s Teach-in process faulty successful Previous teach values and normal Alignment mode operation adopted after Normal operation 1 min without changes LED green 2.5 Hz flashing - Alignment mode is active Signal status (LED yellow): Off - Strength of reflected light inadequate flashes slowly - Strength of reflected light weak flashes quickly - Strength of reflected light improving lit permanently (not flashing) - Strength of reflected light good Press the Teach-In button > 2s Normal operation yellow LED illuminates More stringent adjustment requirements: Ensure that the device is correctly aligned in the near range of 0.2 m ... 0.6 m. Object detection after successful Teach-in The target should be large enough so that the reflector is always completely covered in one dimension! optimal not optimal object = resolution object > resolution Release date: 2015-02-18 11:23 Date of issue: 2015-02-18 217956_eng.xml Signal tracking: Active: * At variable temperature * Objects located in the light path that lie below the switching point. These objects result in a readjustment of the emitter. This allows these objects to be taught in or taught out. Inactive: * Function not available To alter the signal tracking, press the Teach-in button for >10 seconds. The current status is displayed. Briefly pressing the Teach-in button changes the mode. Press the Teach-in button > 10 seconds Signal tracking switch mode Yellow LED 1 Hz Flashes once Flashes twice Tracking on Tracking off Press the Teach-in button Mode is changed Reverts back to normal mode after 5 seconds if no changes are made Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 fa-info@de.pepperl-fuchs.com www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com 3