EMA5 5 W U l t r a m i n i a t u re Medical Encapsulated Switchers series Universal 90-264VAC Input High Efficiency Improved EMI Performance 5656VDC Isolation Single , Dual and Triple Outputs UL60601-1, EN60601-1 & IEC60601-1 Model Number Output Voltage Output Amps FL (peak) Ripple/Noise Efficiency SINGLE OUTPUT - PCB Mount ESMA-5000 3.3 VDC ESMA-5001 5 VDC ESMA-5022 9 VDC ESMA-5002 12 VDC ESMA-5003 15 VDC ESMA-5018 18 VDC ESMA-5005 24VDC 1.25A (1.56A) 1A (1.5A) 0.55 (0.82) 0.42A (0.63A) 0.33A (0.5A) 0.27 (0.4A) 0.23A (0.35A) 165mV pk-pk 100mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 60% 70% 70% 73% 74% 75% 76% SINGLE OUTPUT - Chassis Mount ESMC-5000 3.3 VDC ESMC-5001 5 VDC ESMC-5022 9 VDC ESMC-5002 12 VDC ESMC-5003 15VDC ESMC-5018 18 VDC ESMC-5005 24VDC 1.25A (1.56A) 1A (1.5A) 0.55 (0.82) 0.42A (0.63A) 0.33A (0.5A) 0.27 (0.4A) 0.23A (0.35A) 165mV pk-pk 100mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 60% 70% 70% 73% 74% 75% 76% SINGLE OUTPUT - DIN Rail Mount ESMC-5000/DRL 3.3 VDC ESMC-5001/DRL 5 VDC ESMC-5022/DRL 9 VDC ESMC-5002/DRL 12 VDC ESMC-5003/DRL 15VDC ESMC-5018/DRL 18 VDC ESMC-5005/DRL 24VDC 1.25A (1.56A) 1A (1.5A) 0.55 (0.82) 0.42A (0.63A) 0.33A (0.5A) 0.27 (0.4A) 0.23A (0.35A) 165mV pk-pk 100mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 60% 70% 70% 73% 74% 75% 76% WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 EMA5 5 W U l t r a m i n i a t u re Medical Encapsulated Switchers series Universal 90-264VAC Input High Efficiency Improved EMI Performance 5656VDC Isolation Single ,Dual and Triple Outputs UL60601-1, EN60601-1 & IEC60601-1 Model Number Output Voltage Output Amps FL (peak) Ripple/Noise Efficiency DUAL OUTPUT - PCB Mount EDMA-5006 12 VDC EDMA-5007 15 VDC 0.21A (0.26A) 0.17A (0.21A) 100 mV pk-pk 100 mV pk-pk 71% 71% DUAL OUTPUT - Chassis Mount EDMC-5006 12 VDC EDMC-5007 15 VDC 0.21A (0.26A) 0.17A (0.21A) 100 mV pk-pk 100 mV pk-pk 71% 71% DUAL OUTPUT - DIN Rail Mount EDMC-5006/DRL 12 VDC EDMC-5007/DRL 15 VDC 0.21A (0.26A) 0.17A (0.21A) 100 mV pk-pk 100 mV pk-pk 71% 71% TRIPLE OUTPUT - PCB Mount ETMA-5009 5 12 VDC ETMA-5011 5 15 VDC 0.53 0.1 A / 0.6 0.1 A 0.41 0.1 A / 0.45 0.1 A 50 75 mV pk-pk 50 75 mV pk-pk 63% 61% TRIPLE OUTPUT - Chassis Mount ETMC-5009 5 12 VDC ETMC-5011 5 15 VDC 0.53 0.1 A / 0.6 0.1 A 0.41 0.1 A / 0.45 0.1 A 50 75 mV pk-pk 50 75 mV pk-pk 63% 61% TRIPLE OUTPUT - DIN Rail Mount ETMC-5009/DRL 5 12 VDC ETMC-5011/DRL 5 15 VDC 0.53 0.1 A / 0.6 0.1 A 0.41 0.1 A / 0.45 0.1 A 50 75 mV pk-pk 50 75 mV pk-pk 63% 61% WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 EMA5 5 W U l t r a m i n i a t u re Medical Encapsulated Switchers INPUT SPECIFICATIONS Input Voltage Range Frequency Range Inrush Current, typ: Leakage Current PHYSICAL SPECIFICATIONS 90-264 VAC 47-63 Hz 20A@115V, 40A@230V Input * <500UA @ 264VAC, 50Hz OUTPUT SPECIFICATIONS Voltage and Current Load Regulation (Note7) Line Regulation (Note 8) Cross Regulation (Note 11) Preset Accuracy (Note 9) Temperature Coefficient Ripple/Noise (Note 1, 2, 10) Over Voltage Protection Over Temp. Protection Short Circuit Protection (Note 3) Hold Up Time See Selection Chart Singles/Duals 3%, Triple: 0.5 / 0.5% (max) Singles 0.1~1%, typ Duals 0.3~1%, typ Triple: 0.6 / 0.2% (max) Duals 2% Triple NA / 0.1% 1% 0.03%/C See Selection Chart Clamp Latching, recover after cooling and power is restored Indefinite 30 mS, typ (Nom. Input, 100% load) GENERAL SPECIFICATIONS Isolation (Note 4) Efficiency Switching Frequency Safety EMC series 5656VDC Input-Output 3535VDC I/P-Ground 1414VDC O/P-Ground See Selection Chart 100Khz, (fixed, typical) UL60601-1, EN60601-1 EN55022 All specifications are typical at nominal input, full load, and 25C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Size PCB Mount 2.28L" x 1.77W" x 0.83H" Chassis Mount 3.77L" x 2.16W" x 1.0H" Din Rail 3.77L" x 2.16W" x 1.35H" Case Material Rynite, 94V-0 Rated Construction Encapsulated. Soft Pot Weight PCB / CHA 4 oz (112g) / 8.5 oz (238g) Din Rail 11.5 oz (326g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature (Note 5) Storage Temperature Relative Humidity EMC / EMI MTBF 0 to +50C (See Derate) -25 to +71C * 0 to + 95%, non-cond * FCC/A, VDE 0871/A , CISPRB (Mil Std 217, 25C) 180,000 Hrs NOTES 1. All measurements should be made directly at the terminals of the power supply. 2. Ripple and Noise depend upon output voltage as specified par particular model. 3. Short Circuit Protection is self-recovering when overcurrent condition is removed. 4. Isolation for up to 1minute duration. 5. Specified for free-air convection cooling. 6. Minimum load is NOT required for proper operation. However, auxiliary outputs should be reduced as a function of primary output minimum load or load regulation will be higher. 7. Load regulation measured from 20% to FL. 8. Line regulation measured from 90VAC 264VAC. 9. Preset accuracy measured at nominal load, 120 VAC input. 10. O/P noise measured directly at pins/terminals at nom. load, 0.1uF bypass, pk-pk @20MHz bandwidth. 11. Cross Reg-Triples: Measured at nom. load with the 5V output varied between 60% and 100% of nim. load. 12. 100% Production Tested. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 EMA5 5 W U l t r a m i n i a t u re Medical Encapsulated Switchers series OUTPUT DERATING CURVE 100 90 Load, % 80 70 60 50 40 30 20 0 10 20 30 40 50 60 70 Ambient Temperature, C MECHANICAL DIMENSIONS WWW.ASTRODYNE.COM Model Type / Pin# Single Dual Dual (5008) Triple 1 2 3 4 5 6 7 8 9 ACL ACN No Pin No Pin +Vout No Pin Com -Vout No Pin ACL ACN No Pin No Pin +12V No Pin +5Vout Com No Pin ACL ACN No Pin No Pin +Vout No Pin No Pin -Vout No Pin ACL ACN +Vout Com No Pin -Vout +5Vout +5VRTN No Pin ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 EMA5 5 W U l t r a m i n i a t u re Medical Encapsulated Switchers series MECHANICAL DIMENSIONS - CHASSIS MOUNT 4 1 5 6 2 7 8 3 MECHANICAL DIMENSIONS - DIN RAIL 0.350 [8.89] 0.100 [2.54] 9 Model Type / Pin# Single Dual Dual (5008) Triple 1 2 3 4 5 6 7 8 9 ACN N/C ACL N/C -Vout Com Com +Vout N/C ACN N/C ACL N/C Com Com +5V +12V N/C ACN N/C ACL N/C -Vout -Vout +Vout +Vout N/C ACN N/C ACL N/C +5VRTN +5Vout -Vout Com +Vout DIN Rail mounting kit available for Chassis-mount modules, specify part # M-DRL-01. Kit includes mounting plate, DIN Rail cliip and assembly hardware. WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458