Technical Data 2602
Effective June 2017
Supersedes March 2013
Product features
TDC10 and TDC11
1/4" x 1 1/4" (TDC10) fast-acting (TDC11) time delay
glass tube fuses
•TDC10 fast-acting
•TDC11 time-delay
•Lead free and RoHS compliant
•1⁄4" x 1 1⁄4" physical size
•Glass tube, electroplated brass endcap
construction
•Interrupting rating equals 10 times rated current
•TDC10 Series designed to British Standard
BS2950A
Pb
•Specify part number and product code prefix,
•e.g.: BK/TDC10-20-R
Ordering information
31.8
6.35
Dimensions - mm
Drawing Not to Scale
F
AST
-A
CTING
TDC10 S
PECIFICATIONS
Part Voltage Rating Interrupting Rating (amps @ rated voltage) *
Number Amps (Vac) 1000V 750V 500V 350V 250V 150V 100V 32V
TDC10-50-R 50mA 1000 500mA — — — — — — —
TDC10-60-R 60mA 1000 600mA — — — — — — —
TDC10-100-R 100mA 1000 1 — — — — — — —
TDC10-150-R 150mA 1000 1.5 — — — — — — —
TDC10-250-R 250mA 1000 2.5 — — — — — — —
TDC10-500-R 500mA 750 — 5 — — — — — —
TDC10-750-R 750mA 500 — — 7.5 — — — — —
TDC10-1-R 1 350 — — — 10 — — — —
TDC10-1.5-R 1.5 250 — — — — 15 — — —
TDC10-2-R 2 250 — — — — 20 — — —
TDC10-3-R 3 250 — — — — 30 — — —
TDC10-5-R 5 250 — — — — 50 — — —
TDC10-7-R 7 150 — — — — — 70 — —
TDC10-10-R 10 100 — — — — — — 100 —
TDC10-12-R 12 32 — — — — — — — 120
TDC10-15-R 15 32 — — — — — — — 150
TDC10-20-R 20 32 — — — — — — — 200
TDC10-25-R 25 32 — — — — — — — 250
* Interrupting Rating: Interrupting rating is 10 times the rated current.
** DC Cold Resistance (Measured at <10% of rated current)
Packaging Code
Packaging x Description
BK 100 fuses packed into a cardboard carton
BK1 1000 fuses packed into a cardboard carton