Technical Data 2602
Effective June 2017
Supersedes March 2013
Product features
TDC10 and TDC11
1/4" x 1 1/4" (TDC10) fast-acting (TDC11) time delay
glass tube fuses
TDC10 fast-acting
TDC11 time-delay
Lead free and RoHS compliant
1⁄4" x 1 1⁄4" physical size
Glass tube, electroplated brass endcap
construction
Interrupting rating equals 10 times rated current
TDC10 Series designed to British Standard
BS2950A
Pb
Specify part number and product code prefix,
e.g.: BK/TDC10-20-R
Ordering information
31.8
6.35
Dimensions - mm
Drawing Not to Scale
F
AST
-A
CTING
TDC10 S
PECIFICATIONS
Part Voltage Rating Interrupting Rating (amps @ rated voltage) *
Number Amps (Vac) 1000V 750V 500V 350V 250V 150V 100V 32V
TDC10-50-R 50mA 1000 500mA
TDC10-60-R 60mA 1000 600mA
TDC10-100-R 100mA 1000 1
TDC10-150-R 150mA 1000 1.5
TDC10-250-R 250mA 1000 2.5
TDC10-500-R 500mA 750 5
TDC10-750-R 750mA 500 7.5
TDC10-1-R 1 350 10
TDC10-1.5-R 1.5 250 15
TDC10-2-R 2 250 20
TDC10-3-R 3 250 30
TDC10-5-R 5 250 50
TDC10-7-R 7 150 70
TDC10-10-R 10 100 100
TDC10-12-R 12 32 120
TDC10-15-R 15 32 150
TDC10-20-R 20 32 200
TDC10-25-R 25 32 250
* Interrupting Rating: Interrupting rating is 10 times the rated current.
** DC Cold Resistance (Measured at <10% of rated current)
Packaging Code
Packaging x Description
BK 100 fuses packed into a cardboard carton
BK1 1000 fuses packed into a cardboard carton
Eaton
Electronics Division
1000 Eaton Boulevard
Cleveland, OH 44122
United States
www.eaton.com/electronics
© 2017 Eaton
All Rights Reserved
Printed in USA
Publication No. 2602 BU-SB13328
June 2017
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written
approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly
used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.
Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also
reserves the right to change or update, without notice, any technical information contained in this bulletin.
TDC10 and TDC11
1/4" x 1 1/4" (TDC10) fast-acting (TDC11) time delay glass tube fuses
Technical Data 2602
Effective June 2017
T
IME
-D
ELAY
TDC11 S
PECIFICATIONS
Part Voltage Rating Interrupting Rating (amps @ rated voltage) *
Number Amps (Vac) 1000V 750V 500V 350V 250V 150V 100V
TDC11-50-R 50mA 1000 500mA
TDC11-60-R 60mA 1000 600mA
TDC11-100-R 100mA 1000 1
TDC11-150-R 150mA 1000 1.5
TDC11-250-R 250mA 1000 2.5
TDC11-500-R 500mA 750 5
TDC11-750-R 750mA 500 7.5
TDC11-1-R 1 350 10
TDC11-1.5-R 1.5 250 15
TDC11-2-R 2 250 20
TDC11-3-R 3 250 30
TDC11-5-R 5 250 50
TDC11-7-R 7 150 70
TDC11-10-R 10 100 100
*Interrupting Rating: Interrupting rating is 10 times the rated current.
** DC Cold Resistance (Measured at <10% of rated current)
Time-Current Curves
TDC10 Series TDC11 Series
100 100
10 10
11
.1 .1
.01 .01
Time Rated Current Time Rated Current
Time in Seconds
.1
1
10
100
Time in Seconds
.1
1
10
100