POMEREX T9GO 1000A Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 Phase Control SCR 1000 Amperes Average 2400 Volts CATHODE POTENTIAL TERMINAL FOR .187 INCH / 4.75 MM NOM. PUSH-ON TYPE TERMINAL ett F DIA. TYP. G DEEP TYP, puree po carvoue jn B DIA. | pi. oe | r_ CASE NUMBER T9G NOMINAL DIMENSIONS 1 GATE TERMINAL 8 ga : M - NOM, ANODE PIN RECEPTACLE STRIKE DISTANCE = .58 INCH / 14.7 MM MIN. CREEPAGE DISTANCE = |.00 INCH / 25.4 MM MIN. SYM. A 8 c 0 E FE G H INCHES |] 1.85 2.90 2.60 030 | 1.000/1.080 | .140 085 20 MM 47.0 73.7 | 66.0 0.76 | 25.40727.69 | 3.56 2.16 20 T9GO 1000A (Outline Drawing) Ordering Information: Select the complete 12 digit part number you desire from the table below. Voltage Current Turn-off Gate Current VorwYaRM tay) ty let Lead Type (Volts) (A) (11sec) (mA) Code T9GO 02 10 0 3 DH through 24 200V 1000A 250psec 200mA 12 through (Typical) 2400V TSGO 1000A Phase Control SCR 1000 Amperes Average, 2400 Volts Description: Powerex Silicon Controlled Rectifiers (SCR) are designed for phase control applications. These are all-diffused, Press-Pak, hermetic Pow-R-Disc devices employing the field proven amplifying gate. Features: Low On-State Voltage High di/dt Capability High dv/dt Capability Hermetic Packaging OOOdd Excellent Surge and It Ratings Applications: [] Power Supplies [] Motor Control [] Battery Chargers P-145POWMEREX Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 T9GO 1000A Phase Conirol SCR 1000 Amperes Average, 2400 Volts Absolute Maximum Ratings Characteristics Symbol T9GO 1000A Units Non-repetitive Transient Peak Reverse Voltage VRsmM Varn + 100V Volts RMS On-state Current, To = 82C 'T(rms) 1590 Amperes Average Current 180 Sine Wave, To = 82C (av) 1000 Amperes RMS On-state Current, To = 55C IT(rms) 2100 Amperes Average Current 180 Sine Wave, To = 55C (av) 1340 Amperes Peak One Cycle Surge On-state Current (Non-repetitive) 6(0Hz lism 17000 Amperes Peak One Cycle Surge On-state Current (Non-repetitive) 50Hz lism 15500 Amperes Critical Rate-of-rise of On-state Current (Non-repetitive) di/dt 600 A/usec Critical Rate-of-rise of On-state Current (Repetitive) di/dt 150 A/usec t (for Fusing) for One Cycle, 6OHz t 1,203,000 Asec Peak Gate Power Dissipation Pam 16 Watts Average Gate Power Dissipation Paiav) 3 Watts Operating Temperature Tj -40 to +125C C Storage Temperature Tstg -40 to +150C C Approximate Weight 1 Ib. 454 g Mounting Force 5000 to 5500 Ib. 2270 to 2500 kg P-146POWEREX Ceeeeeeeeeeeeeeee eee eee eee ee Powerex, inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 T9GO 1000A Phase Control SCR 1000 Amperes Average, 2400 Voits Electrical Characteristics, Tj = 25C Unless Otherwise Specified Characteristics Symbol Test Conditions Min. Typ. Max. Units Repetitive Peak Reverse Leakage Current 'RRAM Tj = 125C, Vp = VaRM 75 mA Repetitive Peak Forward Leakage Current lpRM Tj = 125C, Vp = Vora 75 mA Peak On-state Voltage VT tm = 1500A Peak 1.75 Volts Duty Cycle < 0.1% Threshoid Voltage, Low-level Vtoy1 Tj = 125C, | = 15%, Hav) 19 Tay) 0.90398 Volts Slope Resistance, Low-level 'T1 0.49075 =mQ Threshold Voltage, High-level V(ToO)2 Tj = 125C, |= TIT (av) to ITSM 0.96507 ~- Volts Slope Resistance, High-level It2 0.42052 =mQ VT Coefficients, Low-level Tj = 125C, |= 15% Tay) to ayy) Ay = 0.11284 By = 0.08444 Cy = 1.569E-04 D4 = 0.020707 Vtm Coefficients, High-level qj = 125C, 1= TIT (av) to ltsm Ao = 26.048 Bo = -3.9592 Co = 1.118E-04 Do = 0.14391 Typical Turn-on Time ton ITM = 1000A, Vp = 450V 3 psec Typical Turn-off Time tq Tj = 125C, ly = 250A, dip/dt = 50A/ysec 250 usec Reapplied dv/dt = 20V/sec Linear to 80% Vorig Minimum Critical dv/dt - Exponential to Vor dv/dt Tj = 125C 300 1000 Viusec Gate Trigger Current let Tj = 25C, Vp = 12V 30 100 200 mA Gate Trigger Voltage VaT Tj = 26C, Vp = 12V 1.5 3.0 Volts Non-triggering Gate Voltage VGDM Tj = 125C, Vp = VorRM 0.15 Volts Peak Forward Gate Current IoT 4 A Peak Reverse Gate Voltage VGRM 5 Volts Thermal Characteristics Maximum Thermal Resistance, Double Sided Cooling Junction-to-Case Re(j-c) 0.023 C/W Case-to-Sink Rac-s) 0.006 0.0075 C/W P-147TOWEREX Powerex, inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272 Powerex, Europe, S.A. 428 Avenue G. Durand, BP107, 72003 Le Mans, France (43) 41.14.14 T9GO 1000A Phase Control SCR 1000 Amperes Average, 2400 Volts Maximum On-State Forward Voltage Drop Maximum Transient Thermal Impedance ( Tj= 125 C ) (Junction to Case) 0,025 an s 3 os2 E & > g 0.015 & 2 z 0.01 > E a s E 0.005 5 Ee 0 10 100 1000 10000 100000 0,001 0.01 04 1 10 100 instantaneous On-State Current - itm - Amperes Time - t - Seconds Maximum On-State Power Dissipation Maximum Allowable Case Temperature (Sinusoldal Waveform) (Sinusoidal Waveform) 2200 130 2000 2 = 1800 3 120 & 1600 & 110 E 1400 2 B 1200 g 1 = 1000 & 90 B om : es 600 3 E 400 x 3 200 0 60 0 200 400 600 800 1000 4200 0 200 400 600 800 1000 1200 Average On-State Current - It(av) - Amperes Average On-State Current - it(av) - Amperes Maximum On-State Power Dissipation Maximum Allowable Case Temperature (Rectangular Waveform) (Rectangular Waveform) 3000 130 a a 2 420 2500 2 * 8 110 2 = % 2000 100 3 90 5 1500 90 : 1000 : 70 5 z 60 00 i 3 se 9 40 0 200 400, 600s 800-d1000- 1200s: 14001800 1800 0 200 400 "600 800 1000 1200 1400 1600 1800 Average On-State Current - It(av) - Amperes Average On-State Current li(av) - Amperes P-148