Features & Benefits
60 MHz, 100 MHz and
200 MHz Bandwidths
Sample Rates up to 2 GS/s
2 or 4 Channels
Color or Monochrome
LCD Display
Autoset Menu with Waveform
Selection
Probe Check Wizard To
Ensure Correct Probe Usage
Context-sensitive Help
Dual Time Base
Advanced Triggering
11 Automatic Measurements
Multi-language User Interface
Waveform and Setup
Memories
FFT Standard on All Models
Extended Capabilities Are
Provided with Optional
TDS2CMA Module,
WaveStarSoftware and
Probes
Applications
Service and Repair
Education and Training
Manufacturing Test and
Quality Control
Design and Debug
Digital Storage Oscilloscopes
TDS1002 • TDS1012 • TDS2002 • TDS2012 • TDS2014 • TDS2022 • TDS2024
TDS1000 and TDS2000 Series Oscilloscopes.
Colorful Performance at a Black and White Price.
The TDS1000 Series and TDS2000 Series
digital storage oscilloscopes deliver an
unbeatable combination of superior perform-
ance, unmatched ease-of-use and affordability
in an ultra lightweight, portable package.These
new products extend the performance and
ease-of-use features in the former TDS200
Series, the benchmark for low-cost oscilloscopes.
Affordable Digital
Performance
With up to 200 MHz bandwidth and 2 GS/s
maximum sample rate, no other color digital
storage oscilloscope offers as much band-
width and sample rate for the price.The
TDS1000 and TDS2000 Series oscilloscopes
provide accurate real-time acquisition up to
their full bandwidth.These instruments offer
advanced triggering, such as pulse width trig-
gering and line-selectable video triggering,
and 11 standard automatic measurements on
all models.The Fast Fourier Transform (FFT)
math function allows the user to analyze,
characterize and troubleshoot circuits by view-
ing frequency and signal strength (standard
on all models).
Simple User Interface
The simple user interface makes these instru-
ments easy to use, reducing learning time and
increasing efficiency. Classic, analog-style
controls provide instant, front-panel access to
Digital Storage Oscilloscopes • TDS1000 and TDS2000 Series Oscilloscopes • www.tektronix.com/scopes
1
Digital Storage Oscilloscopes
TDS1002 TDS1012 TDS2002 TDS2012 TDS2014 TDS2022 TDS2024
the most frequently used functions.The
autoset function automatically detects sine
waves, square waves and video signals, and
provides readouts of relevant measurements.
This function also allows the user to select
additional views of the signal, such as rising
and falling edges, video lines and fields, and
FFT.The probe check wizard aids the user in
setting the attenuation factor and compensat-
ing the probe.The context-sensitive help
menu with indexed and hyper-linked topics
allows the user to selectively learn about the
operation of any oscilloscope function.The
color LCD display on the TDS2000 Series
models dedicates a different color for each
trace and its associated readouts to simplify
viewing complex signals on multiple channels.
Characteristics
Acquisition Modes
Peak Detect High frequency and random glitch cap-
ture. Captures glitches as narrow as 12 ns typical using
acquisition hardware at all time/div settings from
5 µs/div to 50 s/div.
Sample Sample data only.
Average Waveform averaged, selectable:4,16,
64, 128.
Single Sequence Use the Single Sequence button
to capture a single triggered acquisition sequence
at a time.
Trigger System (Main Only)
Trigger Modes – Auto, Normal, Single Sequence.
Trigger Types
Edge (rising or falling) Conventional level-driven
trigger. Positive or negative slope on any channel.
Coupling selections:AC,DC, Noise Reject, HF Reject,
LF Reject.
Video Trigger on all lines or individual line,
odd/even or all fields from composite video, or
broadcast standards (NTSC, PAL, SECAM).
Pulse Width (or Glitch) Trigger on a pulse width
less than, greater than, equal to or not equal to a
selectable time limit ranging from 33 ns to 10 sec.
Trigger Source
2-channel models CH1, CH2, Ext,Ext/5,AC Line.
4-channel models CH1, CH2, CH3, CH4, Ext,
Ext/5,AC Line.
Trigger View
Displays trigger signal while trigger view button
is depressed.
Digital Storage Oscilloscopes • TDS1000 and TDS2000 Series Oscilloscopes • www.tektronix.com/scopes
2
TDS1000 and TDS2000 Series Electrical Characteristics
TDS1002 TDS1012 TDS2002 TDS2012 TDS2014 TDS2022 TDS2024
Display Mono Mono Color Color Color Color Color
(1/4 VGA LCD)
Bandwidth*160 MHz 100 MHz 60 MHz 100 MHz 100 MHz 200 MHz 200 MHz
Channels 2 222424
External Yes on all models
Trigger Input
Sample Rate 1.0 GS/s 1.0 GS/s 1.0 GS/s 1.0 GS/s 1.0 GS/s 2.0 GS/s 2.0 GS/s
on each channel
Record Length 2.5 K points on all models
Vertical 8-bits
Resolution
Vertical 2 mV to 5 V/div on all models with calibrated fine adjustment
Sensitivity
DC Vertical ± 3% on all models
Accuracy
Vertical Zoom Vertically expand or compress a live or stopped waveform
Max Input 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz and above
Voltage
Position 2 mV to 200 mV/div ± 2 V
Range > 200 mV to 5 V/div ± 50 V
BW Limit 20 MHz for all models
Input Coupling AC, DC, GND on all models
Input Impedance 1 Min parallel with 20 pF
Time Base 5 ns to 5 ns to 5 ns to 5 ns to 5 ns to 2.5 ns to 2.5 ns to
Range 50 sec/div 50 sec/div 50 sec/div 50 sec/div 50 sec/div 50 sec/div 50 sec/div
Time Base 50 ppm
Accuracy
Horizontal Zoom Horizontally expand or compress a live or stopped waveform
*1Bandwidth is 20 MHz at 2 mV/div, all models.
Digital Storage Oscilloscopes
TDS1002 TDS1012 TDS2002 TDS2012 TDS2014 TDS2022 TDS2024
Trigger Signal
Frequency Readout
Provides a frequency readout of the trigger source.
Cursors
Types Voltage,Time.
Measurements []T, 1/[]T (frequency), []V.
Measurement System
Automatic Waveform Measurements Period,
Frequency, +Width, –Width, Rise-time, Fall-time,
Max, Min, Peak-to-Peak,Mean, Cycle RMS.
Waveform Processing
Operators Add, Subtract, FFT.
FFT Windows:Hanning, Flat Top, Rectangular;
2048 sample points.
Sources
2-channel models: CH1 - CH2, CH2 - CH1,
CH1 + CH2.
4-channel models: CH1 - CH2, CH2 - CH1,
CH3 - CH4, CH4 - CH3,CH1 + CH2, CH3 + CH4.
Nonvolatile Storage
Waveform Display Two 2500 point
reference waveforms.
Waveform Storage 2-channel models:Two 2500
point reference waveforms. 4-channel models:
Four 2500 point reference waveforms.
Setups 10 front-panel setups.
Display Characteristics
Display
Monochrome models: 1/4 VGA,backlit passive LCD
with adjustable multi-level contrast and inverse video
selectable from front panel.
Color models: 1/4 VGA,passive color LCD with color on
black background with adjustable multi-level contrast.
Interpolation Sin(x)/x.
Display Types Dots, vectors.
Persistence Off, 1 sec, 2 sec, 5 sec, infinite.
Format YT and XY.
Autoset Menu
Single-button, automatic setup of all channels
for vertical, horizontal and trigger systems, with
undo autoset.
I/O Interface
TDS2CMA Communications
Extension Module
Printer Port Centronics-type parallel.
GPIB (IEEE std. 488-1987) Programmability
Full talk/listen modes. Control of all modes, settings
and measurements. Includes WaveStarsoftware
for oscilloscopes, 30-day product demo.
RS-232 Programmability Full talk/listen modes.
Control of all modes, settings and measurements.
Baud rate up to 19,200. 9-Pin, DTE.
Printer Capability (Requires
TDS2CMA Module)
Graphics File Formats TIFF, PCX (PC Paintbrush),
BMP (Microsoft Windows),EPS (Encapsulated
Postscript) and RLE.
Printer Formats Bubble Jet,DPU-411, DPU-412,
DPU-3445,Thinkjet, Deskjet, LaserJet, and Epson
(9- or 24-Pin).
Layout Landscape or Portrait.
Environmental and Safety
Temperature
Operating: 0°C to +50°C.
Nonoperating: 40°C to +71°C.
Humidity
Operating and Nonoperating: up to 90% RH
at or below +30°C.
Operating: up to 60% RH up to 50°C.
Nonoperating: up to 60% RH up to 55°C.
Altitude
Operating and Nonoperating: up to 3,000 m.
Electromagnetic Compatibility Meets Directive
89/336/EEC, amended by 93/68/EEC, meets or
exceeds EN55011 Class A Radiated and Conducted
Emissions; FCC 47 CFR, Part 15, Subpart B, Class A;
Australian EMC Framework, demonstrated per
Emission Standard AS/NZS 2064; Russian GOST
EMC regulations.
Safety UL3111-1, CSA1010.1, IEC61010-1,
EN61010-1.
Physical Characteristics
INSTRUMENT
Dimensions mm in.
Width 323.8 12.75
Height 151.4 5.96
Depth 124.5 4.90
Weight kg lbs.
Instrument only 2.0 4.4
with accessories 2.2 4.9
INSTRUMENT SHIPPING
Package Dimensions mm in.
Width 476.2 18.75
Height 266.7 10.50
Depth 228.6 9.00
RM2000 RACKMOUNT
Dimensions mm in.
Width 482.6 19.00
Height 177.8 7.00
Depth 108.0 4.25
Instrument Accessories
TDS2CMA Communications Extension Module
(Includes user and programmer manuals. Does not
include I/O cable).
AD007 LAN/WAN GPIB converter.
AC220 Soft case for carrying instrument.
HCTDS32 Hard plastic case for carrying instrument
(requires AC220).
Digital Storage Oscilloscopes • TDS1000 and TDS2000 Series Oscilloscopes • www.tektronix.com/scopes 3
Autoset Menu for Multiple
Signal Types
Signal Type Autoset Menu
Choices
Square wave Single-cycle
Multi-cycle
Rising or Falling Edge
Sine Wave Single-cycle
Multi-cycle
FFT Spectrum
Video (NTSC, PAL, Field:All, Odd or Even
SECAM) Line:All or Selectable
Line Number
For the most up-to-date product information
visit our web site at www.tektronix.com
Copyright © 2002, Tektronix, Inc. All rights reserved. Tektronix products are
covered by U.S. and foreign patents, issued and pending. Information in this pub-
lication supersedes that in all previously published material.Specification and price
change privileges reserved. TEKTRONIX and TEK are registered trademarks of
Tektronix, Inc. All other trade names referenced are the service marks,trademarks
or registered trademarks of their respective companies.
02/02 HB/PG 40W-15314-0
Digital Storage Oscilloscopes • TDS1000 and TDS2000 Series Oscilloscopes • www.tektronix.com/scopes
4
Digital Storage Oscilloscopes
TDS1002 TDS1012 TDS2002 TDS2012 TDS2014 TDS2022 TDS2024
RM2000 Rackmount kit.
Service Manual (TDS1000 and TDS2000 Series
Digital Storage Oscilloscopes) English Only
(071-1076-00).
Programmer Manual (TDS200,TDS1000 and
TDS2000 Series Digital Storage Oscilloscopes)
English only (071-1075-00).
WaveStarSoftware for Oscilloscopes (WSTRO)
Windows 95/98/NT 4.0 application for waveform
capture, analysis, documentation and control from
your PC.
Operator Training Kit – Extensive instructions and
step-by-step lab exercises provide education about
the operation of the TDS1000 and TDS2000 Series
oscilloscopes. Kit includes a self-paced CD-ROM-
based manual and signal source board. (TNGTDS01).
Optional hard copy manual is available for
order separately.
Probes
P2200 10X – 1X switchable passive probe
(200 MHz when 10X is selected).
P6015A 1000X high voltage passive probe
(75 MHz).
P5100 100X high voltage passive probe
(250 MHz).
P5200 High voltage active differential probe
(25 MHz).
P6021 60 MHz AC current probe.
P6022 120 MHz AC current probe.
A621 2000A AC current probe/BNC.
A622 100A AC/DC current probe/BNC.
AM503S AC/DC current probe system.
Ordering Information
TDS1002, TDS1012, TDS2002,
TDS2012, TDS2014, TDS2022,
TDS2024 Digital Storage
Oscilloscopes
Standard Accessories
Probes P2200 200-MHz 10X – 1X Switchable
Passive Probes (one per channel).
Documentation User manual.
Power cord.
NIM/NIST-Traceable Certificate of Calibration.
Warranty Information
Three year warranty covering all labor and parts,
excluding probes.
International Power Plugs
Standard U.S.120 V, 60 Hz (161-0066-00).
Opt. A1 Universal Euro 220 V, 50 Hz
(161-0066-09).
Opt. A2 United Kingdom 240 V, 50 Hz
(161-0066-10).
Opt. A3 Australia 240 V, 50 Hz (161-0066-11).
Opt. A5 Switzerland 220 V, 50 Hz (161-0154-00).
Opt. AC China 240 V, 50 Hz (161-0304-00).
Opt. 99 No power cord.
Accessory Cables
GPIB, 1 m (3.3 ft.) Order 012-0991-01.
GPIB, 2 m (6.6 ft.) Order 012-0991-00.
RS-232, 9-Pin female to 25-Pin male,
4.6 m (15 ft.), for Modems Order 012-1241-00.
RS-232, 9-Pin female to 9-Pin female, null
modem, for computers Order 012-1379-00.
RS-232, 9-Pin female to 25-Pin female, null
modem, for computers Order 012-1380-00.
RS-232, 9-Pin female to 25-Pin male, null
modem, for printers Order 012-1298-00.
Centronics, 25-Pin male to 36-Pin Centronics,
2.4 m (8 ft.), for Parallel Printer Interfaces
Order 012-1214-00.
International User Manual
(TDS1000 and TDS2000 Series
Digital Storage Oscilloscopes,
includes TDS2CMA user
information)
Standard English (071-1064-00).
Opt. L1 French (071-1065-00).
Opt. L2 Italian (071-1066-00).
Opt. L3 German (071-1067-00).
Opt. L4 Spanish (071-1068-00).
Opt. L5 Japanese (071-1069-00).
Opt. L6 Portuguese (071-1070-00).
Opt. L7 Simplified Chinese (071-1071-00).
Opt. L8 Traditional Chinese (071-1072-00).
Opt. L9 Korean (071-1073-00).
Opt. LR Russian (071-1074-00).
Translated front panel overlays included with their
respective user manuals (except Russian).
Contact Tektronix:
ASEAN Countries & Pakistan (65) 6356 3900
Australia & New Zealand (65) 6356 3900
Austria +43 2236 8092 262
Belgium +32 (2) 715 89 70
Brazil & South America 55 (11) 3741-8360
Canada 1 (800) 661-5625
Central Europe & Greece +43 2236 8092 301
Denmark +45 44 850 700
Finland +358 (9) 4783 400
France & North Africa +33 (0) 1 69 86 80 34
Germany +49 (221) 94 77 400
Hong Kong (852) 2585-6688
India (91) 80-2275577
Italy +39 (02) 25086 1
Japan (Sony/Tektronix Corporation) 81 (3) 3448-3111
Mexico, Central America & Caribbean 52 (55) 56666-333
The Netherlands +31 (0) 23 569 5555
Norway +47 22 07 07 00
People’s Republic of China 86 (10) 6235 1230
Poland +48 (0) 22 521 53 40
Republic of Korea 82 (2) 528-5299
Russia, CIS & The Baltics +358 (9) 4783 400
South Africa +27 11 254 8360
Spain +34 (91) 372 6055
Sweden +46 8 477 6503/4
Taiwan 886 (2) 2722-9622
United Kingdom & Eire +44 (0) 1344 392400
USA 1 (800) 426-2200
For other areas contact Tektronix, Inc. at: 1 (503) 627-7111
Updated 8 February 2002