17
G3VM-351A/DG3VM-351A/D
■Absolute Maximum Ratings (Ta = 25°C)
■Electrical Characteristics (Ta = 25°C)
■Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
■Engineering Data
Load Current vs. Ambient Temperature
G3VM-351A(D)
■Safety Precautions
Refe r to page 6 fo r prec autions common to all G3VM models.
Item Symbo l Rating Unit Measurement Conditions
Input LED forward current IF50 mA
Repetitive peak LED forward
current IFP 1 A 100 ms pulses, 100 pps
LED forw ard cur rent re duction
rate D IF/°C-0.5 mA/°CTa ³ 25°C
LED reverse voltage VR5V
Connection temperature Tj125 °C
Output Output dielectric strength VOFF 350 V
Continuous load current IO120 mA
ON current reduction rate D ION/°C-1.2 mA/°CTa ³ 25°C
Connection temperature Tj125 °C
Dielectric strength between input and
output (See note 1.) VI-O 2,500 Vrms AC for 1 min
Operating temperature Ta-40 to +85 °C With n o ic in g o r conde nsation
Storage temperature Tstg -55 to +125 °C With n o i cin g o r conde nsation
Soldering temperature (10 s) --- 260 °C 10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Item Symbol Mini-
mum Typical Maxi-
mum Unit Measurement
conditions
Input LED forward voltage VF1.0 1.15 1.3 V IF = 10 mA
Reverse current IR--- --- 10 mAV
R= 5 V
Capacity between terminals CT--- 30 - -- pF V = 0, f = 1 MHz
Trigger LED forward current IFT ---13mAI
O = 120 mA
Output Maximum resistance with output ON RON --- 25 35 WIF = 5 mA,
IO = 120 mA, t < 1 s
--- 35 50 WIF = 5 mA,
IO = 120 mA
Current leakage when the relay is
open ILEAK --- --- 1.0 mAV
OFF = 350 V
Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V
Insulation resistance RI-O 1,000 --- --- MWVI-O = 500 VDC,
RoH £ 60%
Turn-ON time tON --- 0.3 1.0 ms IF = 5 mA, RL = 200 W,
VDD = 20 V (See note 2.)
Turn-OFF time tOFF --- 0.1 1.0 ms
10% 90%
VOUT
IF
tON tOFF
IF1
2
4
3
RLVDD
VOUT
Note: 2. Turn-ON and Turn-OFF
Times
Item Symbol Minimum Typical Maximum Unit
Output dielectric strength VDD --- --- 280 V
Operating LED forward current IF57.525mA
Continuous load curren t IO--- --- 100 mA
Operating temperature Ta- 20 --- 65 °C
Ambient temperature (°C)
Load current (mA)
80
100
120
140
60
40
20
0
−20 0 20 40 60 80 100