Edition: 02/2003
Rast 5 Power Relay 419 01
2 pole 16 A, DC- and AC-coil
Contact data
Configuration 2 N/O contact
Type of contact single contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Contact material AgCdO, AgNi
Contact gap >3 mm
Features
·Safety mains insulation
·Contact gap > 3 mm
·4 kV / 8 mm coil-contact
·Ambient temperature up to 90°C
·Faston connectors (DIN 46244)
·Snap or screw mounting
Applications
Industrial and domestic appliances, absolute safe power supply
disconnection
VZHSDN
Technical data of approved types on request
Contact ratings
Type Load Operations
DC-version 16 A, 250 Vac, resistive 2.5x105
DC-version 12 A, 250 Vac, resistive 2.5x105
AC-version 16 A, 250 Vac, resistive 1x105
AC-version 12 A, 250 Vac, resistive 1x105
Coil data
Nominal voltage DC coil 6...24 Vdc
AC coil 120...400 Vac
Nominal coil power DC coil 1.3 W
AC coil 2.0...2.5 VA
Operate category 2 / c
Coil versions, DC coil
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vdc Vdc Vdc Vdc cmA
31 12 7.7 0.9 19.5 118+10% 102.0
29 24 15.5 1.8 39.0 470+10% 51.0
Coil versions, AC coil
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vac, 50 Hz Vac Vac Vac cmA
14 110...120 93.0 18.0 132.0 1650+10% 20.0
10 220...240 187.0 36.0 264.0 6600+10% 10.0
09 380...400 323.0 60.0 440.0 20000+10% 6.0
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request
F0255-A
Edition: 02/2003
Insulation
Dielectric strength coil-contacts 4000 Vrms
open contact circuit 2000 Vrms
Clearance / creepage 8 / 8 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation to VDE 0110b (2/79)
Insulation category / reference voltage C / 380
Tracking resistance of relay base CTI 600M
Rast 5 Power Relay 419 01
2pole 16 A, DC- and AC-coil
Other data
Ambient temperature -20...+90 °C
Mechanical life >2x106operations
Max. switching rate at rated- / minimum load 15 min-1 /600 min-1
Operate- / release time typ. 15 / 15 ms
Bounce time typ. 4 ms
Vibration resistance 2 g, 5...500 Hz
Shock resistance (destruction) 80 g
Category of protection (IEC 61810) RT I - dust protected
Relay weight 90 g
Packaging unit 42 pcs.
Terminal assignmentSnap-on mount / Dimensions
Dimensions in mm
S0447-AA
Rights to change data / design reserved
Edition: 02/2003
Rast 5 Power Relay 419 01
2pole 16 A, DC- and AC-coil
Terminal assignmentScrew mount / Dimensions
Dimensions in mm
S0447-AB