Miniature Low Pressure
Flow-Through Sensors
26PC Series, Compensated/Unamplified
1 psi to 100 psi
Datasheet
2sensing.honeywell.com
Miniature Low Pressure Flow-Through Sensors
The 26PC Series Miniature Low Pressure Flow-Through Sensors feature proven sensing technology that uses a specialized
piezoresistive micromachined sensing element to offer high performance, reliability, and accuracy.
Each sensor contains four active piezoresistive elements in a Wheatstone bridge configuration. When pressure is applied,
the resistance changes and provides an output signal in mV proportional to the input pressure.
The low power, compensated, unamplified Wheatstone bridge circuit design offers 1 psi through 100 psi sensing ranges
in a variety of pressure port types and termination configurations. The mV output is available in both negative and positive
voltage.
Visit www.honeywell.com/sensing to download 3D CAD drawings in IGES and STEP format, and 2D drawings in PDF
format.
These sensors are intended for use with media compatible with plastics and media seals specified in the Nomenclature
and Order Guide (see Figure 2). (2D drawings also provide plastic housing and port material information.) They are designed
and manufactured according to ISO 9001 standards.
26PCXXG6D
26PCXXG6G
26PCXXP5G
For all available configurations, see Figure 3.
What makes our sensors better?
Selectable seals available to match media used
Higher pressure ranges for use in high pressure applications
Minimal dead space inhibits bacterial growth
Available in both SIP and DIP packages
Available with cable harness to allow off-board sensing
MiniMal DeaD Space • cable HarneSS aVailable • SelecTable SealS
3
sensing.honeywell.com
FLOW THROUGH DESIGN IN MINIATURE, PLASTIC PACKAGE
Provides a reduced-cost alternative (versus stainless steel package)
INTEGRATED FLOW THROUGH DESIGN
Eliminates the need for many additional connections and parts
VARIETY OF PRESSURE RANGES FROM 1 PSI TO 100 PSI
Allows use in a wide variety of applications
ABSOLUTE, DIFFERENTIAL, WET-WET DIFFERENTIAL, GAGE AND
VACUUM GAGE MEASUREMENT TYPES
Allow customers to choose the sensor that fits their applications
ROBUST MEDIA COMPATIBILITY
Requires no gel coating
DURABLE
Operable after exposure to frozen conditions
ALSO AVAILABLE IN DIP, SIP, AND SMT PACKAGES
Provides added design flexibility
Features
and Benefits
In-line use minimizes the number of pneumatic
connections and helps reduce system dead space.
By matching pressure ranges to the application, we optimize
resolution and improve system accuracy.
4sensing.honeywell.com
MEDICAL
HEMODIALYSIS
May be used to monitor the correct pressure to help ensure optimal blood
filtration
Potential Applications
Table 1. Absolute Maximum Ratings1
Characteristic Min. Typ. Max. Unit Note
Supply voltage 2.5 10 16 Vdc
Input resistance 5.5 7. 5 11.5 kOhm
Output resistance 1.5 2.5 3kOhm
Time response 1 ms 2
1Absolute maximum ratings are the extreme limits the device will withstand without damage.
2Time required for the output to increase from 10% to 90% of span in response to a step change in input pressure from the specified min. to max.
operating pressure.
Table 2. Technical Specifications
Characteristic Parameter
Operating temperature range:
without EPDM seals
with EPDM seals
-40 °C to 85 °C [-40 °F to 185 °F]
-20 °C to 85 °C [-4 °F to 185 °F]
Compensated temperature range 0 °C to 50 °C [32 °F to 122 °F]
Storage temperature range 55 °C to 100 °C [-67 °F to 212 °F]
Soldering terminal temperature/time 315 °C [599 °F] max./10 s max.
Vibration 10 G at 20 Hz to 2000 Hz
Shock 100 G for 11 ms
Life 1 million cycles min.
5
sensing.honeywell.com
26PC Series, Compensated/Unamplified
Figure 1. Circuit Diagram
Table 3. Performance Characteristics (Vcc =10.00 ±0.01 Vdc; Ta = 25 °C [77 °F])
Characteristic
Operating Pressure Range
Unit Note
0 psi to
1 psi
0 psi to
5 psi
0 psi to
15 psi
0 psi to
30 psi
0 psi to
100 psi 38 psi-low
Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max. Typ. Max.
Span 16.7 ±2 50 ±3 100 ±3 100 ±3 100 ±5 39.5 ±2 mV 1
Null offset 0 ±1.5 0 ±1.5 0 ±1.5 0 ±1.5 0 ±2.0 0 ±1.5 mV 2
Linearity
(Best Fit Straight
Line, P2>P1)
0.25 0.5 0.4 0.5 0.25 0.5 0.1 0.2 0.4 0.6 0 .1 0.5 %span 3
Null shift
(0 °C to 25 °C;
25 °C to 50 °C)
±0.5 ±1.0 ±0.5 ±1.0 ±0.5 ±1.0 ±0.75 ±1.5 ±1.0 ±0.5 ±0.7 ±1.5 mV 4
Span shift
(0°C to 25°C;
25 °C to 50 °C)
±1.0 ±2.0 ±1.0 ±1.5 ±0.75 ±1.5 ±0.75 ±1.5 ±0.5 ±1.5 ±1.0 ±1.5 %span 5
Repeatability and
hysteresis ±0.5 ±0.2 ±0.2 ±0.2 ±0.2 ±0.2 mV 6
Overpressure 20 20 45 60 200 60 psi 7
1Span is the algebraic difference between the output signal measured at the upper and lower limits of the operating pressure range, where
Port 2 (P2) > Port 1 (P1).
2The output signal obtained when zero pressure is applied to all available ports.
3The maximum deviation of product output from a straight line fitted to the output measured over the specified operating pressure range, calculated
according to BFSL. The straight line is fitted along a set of points that minimizes the sum of the square of the deviations of each of the points (“least-
squares” method),
4The maximum deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at a reference
temperature of 25 °C.
5The maximum deviation in span due to changes in temperature over the compensated temperature range, relative to full-scale span measured at a
reference temperature of 25 °C.
6Repeatability is the maximum difference between the output readings when the same pressure is applied consecutively, under the same operating
conditions, with pressure approaching from the same direction within the specified operating pressure range. Hysteresis is the maximum difference
between output readings when the same pressure is applied consecutively, under the same operating conditions, with pressure approaching from
opposite directions within the specified operating pressure range.
7Overpressure is the maximum pressure that may safely be applied to the product for it to remain in specification once pressure is returned to the
operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all
available pressure ports at any temperature within the operating temperature range.
Symbol Description
Vcc supply
OUTPUT A bridge positive output
GROUND ground
OUTPUT B bridge negative output
PIN 1
VCC
PIN 2
OUTPUT
A
PIN 4
Output “A” increases as P2 pressure increases.
Output “B” deceases as P2 pressure increases.
OUTPUT
B
PIN 3
GROUND
6sensing.honeywell.com
Miniature Low Pressure Flow-Through Sensors
Figure 3. All Available Configurations
26PCXXG5G
26PCXXP2G 26PCXXP5G 26PCXXU5G
26PC
Product Series
B
Pressure Range
26PC Series Miniature Low Pressure Flow-Through Sensors,
Compensated/Unmplied
Notes:
1. Every combination may not be possible. Contact customer service.
2. Available in 0.5 psi, 1 psi, 5 psi and 15 psi pressure ranges only.
3. Various wire harnesses with end connector options are available. Contact customer service.
For example, a 26PCBEG6G catalog listing defines a 26PC Series Miniature Low Pressure Flow-Through Sensor, Compensated/Unamplified
5 psi pressure range, EPDM seal material, small flow-through pressure port type, 1x 4 SIP/15,2 mm [0.60 in] long termination configuration,
normal polarity output, and gage pressure measurement type.
26PC Series
Miniature Low
Pressure Flow-Through
Sensors,
Compensated/
Unamplified
A
B
1 psi
5 psi
C15 psi
D30 psi
E
Seal Material
F
E
fluorosilicone
EPDM
Nneoprene2
G
Pressure Port Type
G
P
Small flow-through
Flow-through,
long ends,
UFlow-through,
short ends
6G
Te rmination Configuration,
Output, Pressure
Measurement Type
2G 2 x 2 DIP, normal polarity, gage
5G
1 x 4 SIP for wire harness3,
normal polarity, gage
6G 1 x 4 SIP, 15,2 mm [0.60 in] long,
normal polarity, gage
F100 psi
J38 psi-low
1Every combination may not be possible. Contact customer service.
2Available in 1 psi, 5 psi and 15 psi pressure ranges only.
3Various wire harnesses with end connector options are available. Contact customer service.
Figure 2. Nomenclature and Order Guide1
26PCXXG6G
7
sensing.honeywell.com
26PC Series, Compensated/Unamplified
Figure 4. Pressure Port Types and Termination Configuration Dimensions (For reference only: mm)
26PCXXG5G
26PCXXG6G
8sensing.honeywell.com
Miniature Low Pressure Flow-Through Sensors
Figure 4. Pressure Port Types and Termination Configuration Dimensions (continued)
26PCXXP2G
26PCXXP5G
9
sensing.honeywell.com
26PC Series, Compensated/Unamplified
Figure 4. Pressure Port Types and Termination Configuration Dimensions (continued)
26PCXXU5G
10,8
[0.43]
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
honeywell.com
Find out more
Honeywell serves its customers
through a worldwide network
of sales offices, representatives
and distributors. For application
assistance, current specifications,
pricing or name of the nearest
Authorized Distributor, contact
your local sales office.
To learn more about Honeywell’s
sensing and control products,
call +1-815-235-6847 or
1-800-537-6945,
visit sensing.honeywell.com,
or e-mail inquiries to
info.sc@honeywell.com
32307743-A-EN GLO
May 2015
© 2015 Honeywell International Inc. All rights reserved.
ADDITIONAL INFORMATION
The following associated literature is available at sensing.honeywell.com:
•ProductLineGuide
•ProductRangeGuide
•ProductInstallationInstructions
•Application-SpecificInformation
•TechnicalInformation
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s standard
product warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted
goods are returned to Honeywell during the period of coverage,
Honeywell will repair or replace, at its option, without charge
those items it finds defective. The foregoing is buyer’s sole
remedy and is in lieu of all other warranties, expressed or
implied, including those of merchantability and fitness for
a particular purpose. In no event shall Honeywell be liable
for consequential, special, or indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell website, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the product
could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
• Theinformationpresentedinthisproductsheetisfor
reference only. Do not use this document as a product
installation guide.
• Completeinstallation,operation,andmaintenance
information is provided in the instructions supplied with each
product.
Failure to comply with these instructions could result in
death or serious injury.