DO NOT
SCALE FROM
THIS PRINT
PLATING SPECIFICATION
-G: 20µ" SELECTIVE GOLD
(USE HTS-36-G)
-T: MATTE TIN
(USE HTS-36-L)
(USE HSS-36-L FOR
STYLES -J, -L-X, -M
NO OF POSITIONS
-01 THRU -36
OPTION
-N: NON-FLUSH
(USE SSB-32-U BODY)
(LEAVE BLANK FOR STANDARD)
TERMINAL STYLE
(SEE TABLE 1)
HTS-1XX-X-X-X-X-X
.100
REF
2.54
(NO OF POSITIOINS x .100 [2.54]
.005
MAX
0.13
(N/A ON -N)
.477 12.12
REF
"X" MAX
.018
REF
0.46
.018
REF
0.46
FIG 1
HTS-120-X-AA-1 SHOWN
+.005 [0.13]
C
C
.-.008 [0.20]
SHEET OF
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS ANGLES
.XX:
.01 [.3] 2
.XXX:
.005 [.13]
.XXXX:
.0020 [.051]
MATERIAL:
HIGH TEMP, TERMINAL STRIP ASSEMBLY
BY:
HTS-1XX-X-X-X-X-X
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
L.W.
01/05/1984
4
1
SHEET SCALE: 2:1
INSULATOR: LCP,UL 94 V0, COLOR: BLACK
TERMINAL: BRASS, 1/2 HARD
F:\DWG\MISC\MKTG\HTS-1XX-X-X-X-X-X-MKT.SLDDRW
NOTES:
1. REPRESENTS A CRITICAL DIMENSION.
2.
MAXIMUM ALLOWABLE BOW: .004[0.10] IN/IN TOP TO BOTTOM
.008[0.20] IN/IN SIDE TO SIDE.
3. MINIMUM PUSHOUT FORCE: 5 LBS.
4. MAXIMUM ALLOWABLE TOE IN/OUT OF TERMINALS: 2°.
5. MAXIMUM ALLOWABLE FLASH AFTER REMOVAL OF CROSS BARS: .005[0.13].
6. FOR LEAD STYLES PACKAGED IN TUBES: PACKAGE -05 THRU -36 POSITIONS IN TUBES;
LAYER PACKAGE POSITIONS -01 THRU -04 (SEE TABLE 1).
7. MAXIMUM ALLOWABLE FLASH: .010[0.25].
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
REVISION AI