Edition: 11/2003
Power PCB Relay 429 00 / 429 10 / 429 01
1 pole 10 A / 16 A, DC-coil
Contact data
Configuration 1 C/O, 1 N/O or 1 N/C contact
Type of contact single contact
Rated current 10 A 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Rated voltage / max.breaking voltage DC 250 Vdc
Maximum breaking capacity AC 2500 VA 4000 VA
Make current (max. 4 s at duty cycle 10%) 20 A
Contact material AgCdO, AgNi
Features
•1 C/O, 1 N/O or 1N/C contact
•15 mm height
•Ambient temperature up to 105°C
•4 kV / 8 mm coil-contact
Applications
General purpose power relay, timers, heating controls,
domestic appliances
Coil versions C/O contact
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vdc Vdc Vdc Vdc cmA
16 6 4.1 0.4 12.0 80+10% 75.0
13 12 8.1 0.9 24.0 300+10% 40.0
10 18 12.2 1.3 36.0 690+10% 26.1
08 24 16.2 1.8 48.0 1200+10% 20.0
06 36 24.3 2.7 72.0 2600+10% 13.8
05 48 32.4 3.6 96.0 4825+10% 10.0
03 60 40.5 4.5 120.0 7500+10% 8.0
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request
Contact ratings
Type Load Operations
1 C/O 42900 16 A, 250 Vac,
cosϕ=1
3x104
1 N/O, N/C 42900 16 A, 250 Vac,
cosϕ=1
5x104
1 N/O 42900 10 A, 250 Vac,
cosϕ=1
3x105
1 C/O 42900 10 A, 400 Vac,
cosϕ=1
8x104
Coil data
Nominal voltage DC coil 3...60 Vdc
Nominal coil power DC coil 0.48 W (C/O), 0.42 W (N/O, N/C)
Operate category 1 / b
F0247-A
VZ S H
Technical data of approved types on request