wound0103_reli-PRP2 wound0103_reli_e-01
■ RELIABILITY DATA
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
1.Operating temperature Range
LB, LBC, LBR, LBMF Series
ー40~+105℃(Including self-generated heat)CB, CBC, CBL, CBMF Series
LBM Series
LEM Series ー40~+85℃
2.Storage
LB, LBC, LBR, LBMF Series
ー40~+85℃CB, CBC, CBL, CBMF Series
LBM, LEM Series
【Test Methods and Remarks】
Please refer the term of "7. storage conditions" in precautions.
3.Rated Current
LB, LBC, LBR, LBMF Series
Within the specified toleranceCB, CBC, CBL, CBMF Series
LBM, LEM Series
【Test Methods and Remarks】
LEM Series The maximum DC value having inductance decrease within 10% and temperature increase within 20℃ by the application of DC bias.
4.Inductance
LB, LBC, LBR, LBMF Series
Within the specified toleranceCB, CBC, CBL, CBMF Series
LBM, LEM Series
【Test Methods and Remarks】
LEM Series Measuring equipment:LCR Meter(HP4285A+42851A or its equivalent)
Measuring frequency:Specified frequency
LB・LBC・LBR・CB・CBC・CBL・LBMF・CBMF・LBM Series Measuring equipment:LCR Mater(HP4285A or its equivalent)
5.Q
LB, LBC, LBR, LBMF Series
CB, CBC, CBL, CBMF Series
LBM, LEM Series Within the specified tolerance
【Test Methods and Remarks】
LEM Series Measuring equipment:LCR Meter (HP4285A+42851A or its equivalent)
Measuring frequency:Specified frequency
LBM Series Measuring equipment:LCR Mater(HP4285A or its equivalent)
6.DC Resisitance
LB, LBC, LBR, LBMF Series
Within the specified toleranceCB, CBC, CBL, CBMF Series
LBM, LEM Series
【Test Methods and Remarks】
Measuring equipment:DC Ohmmeter(HIOKI 3227 or its equivalent)
7.Self-Resonant Frequency
LB, LBC, LBR, LBMF Series
Within the specified toleranceCB, CBC, CBL, CBMF Series
LBM, LEM Series
【Test Methods and Remarks】
Measuring equipment:Impedance analyzer(HP4291A or its equivalent)
8.Temperature Characteristic
LBM2016 LEM2520 Inductance change:Within±5%
LB1608 LB2012 LBR2012 CB2012 CBL2012 LB2016
CB2016 LB2518 LBR2518 CB2518 LBC3225 CBC3225 Inductance change:Within±20%
LBMF1608 CBMF1608 LBC2016 CBC2016 LBC2518
CBC2518 LB3218 Inductance change:Within±25%
LBC2012 CBC2012 Inductance change:Within±35%
【Test Methods and Remarks】
Change of maximum inductance deviation in step 1-5
LB, CB Series Step 1 2 3 4 5
Temperture(℃) 20 ー40 20 (Reference temperature) +85 (Maximum operating temperature)20
LEM2520 Step 1 2 3 4 5
Temperture(℃) 20 ー25 20 (Reference temperature) +85 (Maximum operating temperature)20
9.Rasistance to Flexure of Substrate
LB, LBC, LBR, LBMF Series
No damage.CB, CBC, CBL, CBMF Series
LBM, LEM Series
【Test Methods and Remarks】
Warp: 2mm(LB・LBC・LBR・CB・CBC・CBL・LBM・LBMF・CBMF Series)
Pressing jig
Board
LB・LBMF・
CBMF1608
: 0.8mm
Others : 1.0mm
LEM2520:1.6mm
3mm(LEM2520)
Test substrate: Board according to JIS C0051