Amprobe® Test Tools www.Amprobe.com
Data Sheet
Display: 3-3/4 digits 4000 counts LCD display
Update Rate: 3 per second nominal
Polarity: Automatic
Operating Temperature: 0 °C to 40 °C; < 80% RH for temperature up to 31 °C decreasing linearly to 50% RH at 40 °C
Altitude: Operating below 2000m; Indoor use
Storage Temperature: -20 °C to 60 °C, < 80% RH (with battery removed)
Temperature Coefficient: nominal 0.15 x (specified accuracy)/°C @(0 °C ~ 18 °C or 28 °C ~ 40 °C)
Low Battery: Below approx. 2.4V
Power Supply: 3V coin battery IEC-CR2032
Power Consumption: 2.8 mA typical except that 3.3 mA typical for ACA function
APO Timing: Idle for 30 minutes
APO Consumption: 5 μA typical
Dimension: 190 x 63 x 32 mm (7.4 x 2.5 x 1.3 in)
Weight: 139 gm approx
Jaw opening & Conductor diameter: max 26 mm
Special Features: 30ms Max Hold; Data Hold; Relative Zero mode
Safety: Meets EN61010-2-032, UL61010B-2-032, IEC61010-1 2nd Ed., EN61010-1
2nd Ed., UL61010-1 2nd Ed. CAT III-600 Volts ac & dc; Pollution degree : 2
EMC: Conforms to EN61326-1.
This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility)
and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in
the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that
may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results
when making measurements in the presence of electronic interference.
General Specifications
ACD-10 TRMS-PLUS 600A Clamp-On Multimeter
DC Voltage
400.0 mV ±( 0.3% + 4 digits)
4.000, 40.00, 400.0 V ±( 0.5% + 3 digits)
600 V ±( 1.0% + 4 digits)
NMRR: >50 dB @ 50/60Hz
CMRR: >120 dB @ DC, 50/60 Hz, Rs=1 kW
Input Impedance: 10 MW, 30 pF nominal (1000 MW for 400.0 mV range)
Transient protection: 6.5 kV (1.2/50 μs surge)
AC Voltage (50Hz ~ 500Hz)
4.000, 40.00, 400.0 V ±( 1.5% + 5 digits)
600 V ±( 2.0% + 5 digits)
CMRR: >60dB @ DC to 60 Hz, Rs=1 kW
Maximum Crest Factor: < 1.75 : 1 at full scale & < 3.5 : 1 at half scale limited to
fundamental and harmonics, that fall within the meter
specified AC bandwidth for non-sinusoidal waveforms
Input Impedance: 10 MW, 30 pF nominal
Transient protection: 6.5 kV (1.2/50μs surge)
ACD-10 TRMS Plus: True RMS sensing - 5 % to 100 % of range
Electrical Specification Accuracy (23 °C ± 5 °C & < 75% R.H.)
Function Range Accuracy