REVISIONS
LTR DESCRIPTION DATE (YR-MO-DA) APPROVED
A Drawing updated to reflect current requirements. - lgt 01-08-03 Ray mond Monnin
THE ORIGINAL FIRST SHEET OF THIS DRAWING HAS BEEN REPLACED.
REV
SHEET
REV
SHEET
REV STATUS
OF SHEETS
REV A A A A A A A A A A A A
SHEET 1 2 3 4 5 6 7 8 9 10 11 12
PMIC N/A PREPARED BY
Rick C. Officer
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216
http://www.dscc.dla.mil
STANDARD
MICROCIRCUIT
DRAWING
THIS DRAWING IS AVAILABLE
FOR USE BY ALL
DEPARTMENTS
AND AGENCIES OF THE
DEPARTMENT OF DEFENSE
AMSC N/A
CHECKED BY
Charles Reusing
APPROVED BY
Michael Frye MICROCI RCUIT, LINEAR, QUAD 8-BIT
MULTIPLYING CMOS, DIGITAL-TO-ANALOG
CONVERTER WITH MEMORY, MONOLITHIC
SILICON
DRAWING APPROVAL DATE
03 November 1989
REVISION LEVEL
A SIZE
A CAGE CODE
67268 5962-89678
SHEET 1 OF 12
DSCC FORM 2233
APR 97 5962-E543-01
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
1. SCOPE
1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in
accordance with MIL-PRF-38535, appendix A.
1.2 Part or Identifying Number (PIN). The complete PIN is as shown in the following example:
5962-89678 01 X X
Drawin
g
number Device t
y
pe Case outline Lead finish
(see 1.2.1) (see 1.2.2)
(
see 1.2.3
)
1.2.1 Device type(s). The device type(s) identify the circuit function as follows:
Device type Generic number Circuit function
01 DAC-8408A Quad 8-bit multiplying CMOS, digital-to-analog converter with memory
02 DAC-8408B Quad 8-bit multiplying CMOS, digital-to-analog converter with memory
1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows:
Outline letter Descriptive designator Terminals Package style
X GDIP1-T28 or CDIP2-T28 28 Dual-in-line
1.2.3 Lead finish. The lead finish is as specified in MIL-PRF-38535, appendix A.
1.3 Absolute maximum ratings.
VDD to IOUT2 (pins 5, 24) ........................................................................ 0 V dc to +7.0 V dc
VDD to DGND ........................................................................................ 0 V dc to +7.0 V dc
IOUT2 (pins 5, 24) to DGND ................................................................... -0.3 V dc to VDD +0.3 V dc
Digital input voltage to DGND .............................................................. -0.3 V dc to VDD +0.3 V dc
Output voltage (pins 4, 6, 23, 25) to DGND.......................................... -0.3 V dc to VDD +0.3 V dc
VREFA, VREFB, VREFC, VREFD to DGND ....................................................
25 V dc
Voltage from RFBA, RFBB, RFBC, RFBD to DGND.....................................
25 V dc
Power dissipation (PD) to +75
C........................................................... 45 mW 1/
Storage temperature range .................................................................. -65
C to +150
C
Lead temperature (soldering, 60 seconds)........................................... +300
C
Thermal resistance, junction-to-case (
JC) ........................................... See MIL-STD-1835
Thermal resistance, junction-to-ambient (
JA)...................................... 120
C/W
1.4 Recommended operating conditions.
Ambient operating temperature range (TA) .......................................... -55
C to +125
C
Reference voltage (VREF)...................................................................... +10 V
VOUT1 and VOUT2 .................................................................................... 0 V
VDD .......................................................................................................................................................... +5 V
10%
Source resistance (RS) ........................................................................ 50
1/ Derate above +75
C at 6.0 mW/
C.
STANDARD SIZE 5962-89678
A
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS REVISION LEVEL SHEET
COLUMBUS, OHIO 43216-5000 A
DSCC FORM 2234
APR 97
2
2. APPLICABLE DOCUMENTS
2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a
part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed
in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in
the solicitation.
SPECIFICATION
DEPARTMENT OF DEFENSE
MIL-PRF-38535 -- Integrated Circuits, Manufacturing, General Specification for.
STANDARDS
DEPARTMENT OF DEFENSE
MIL-STD-883 - Test Method Standard Microcircuits.
MIL-STD-1835 - Interface Standard Electronic Component Case Outlines.
HANDBOOKS
DEPARTMENT OF DEFENSE
MIL-HDBK-103 -- List of Standard Microcircuit Drawings.
MIL-HDBK-780 - Standard Microcircuit Drawings.
(Unless otherwise indicated, copies of the specification, standards, and handbooks are available from the Standardization
Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text
of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-
JAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer
Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-
PRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying
activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan
may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device.
These modifications shall not affect the PIN as described herein. A "Q" or "QML" certification mark in accordance with MIL-
PRF-38535 is required to identify when the QML flow option is used.
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as
specified in MIL-PRF-38535, appendix A and herein.
3.2.1 Terminal connections. The terminal connections shall be as specified on figure 1.
3.2.2 Truth table. The truth table shall be as specified on figure 2.
3.2.3 Functional diagram. The functional diagram shall be as specified on figure 3.
3.2.4 Case outline. The case outline shall be in accordance with 1.2.2 herein.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full ambient operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are described in table I.
STANDARD SIZE 5962-89678
A
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS REVISION LEVEL SHEET
COLUMBUS, OHIO 43216-5000 A
DSCC FORM 2234
APR 97
3
3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN
listed in 1.2 herein. In addition, the manufacturer's PIN may also be marked as listed in MIL-HDBK-103 (see 6.6 herein). For
packages where marking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer has the
option of not marking the "5962-" on the device.
3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance
to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a "Q" or "QML" certification mark in
accordance with MIL-PRF-38535 to identify when the QML flow option is used.
3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an
approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DSCC-VA prior to
listing as an approved source of supply shall affirm that the manufacturer's product meets the requirements of MIL-PRF-
38535, appendix A and the requirements herein.
3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided
with each lot of microcircuits delivered to this drawing.
3.8 Notification of change. Notification of change to DSCC-VA shall be required in accordance with MIL-PRF-38535,
appendix A.
3.9 Verification and review. DSCC, DSCC's agent, and the acquiring activity retain the option to review the manufacturer's
facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the
reviewer.
4. QUALITY ASSURANCE PROVISIONS
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535,
appendix A.
4.2 Screening. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices
prior to quality conformance inspection. The following additional criteria shall apply:
a. Burn-in test, method 1015 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall
specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in
test method 1015 of MIL-STD-883.
(2) TA = +125
C, minimum.
b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter
tests prior to burn-in are optional at the discretion of the manufacturer.
STANDARD
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
SIZE
A 5962-89678
REVISION LEVEL
A SHEET 4
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics.
Conditions
-55
C
TA
+125
C Group A Device Limits
Test Symbol VOUT1 = VOUT2 = 0 V subgroups type
VDD = +5 V;
VREF =
10 V
unless otherwise specified
Min
Relative accuracy INL 1, 2, 3 01
02
Differential DNL 1, 2, 3 01
nonlinearity 02
Gain error GFSE 1, 2, 3 All
DC power supply PSRR 1, 2, 3 All
Gain
rejection 1/
VDD
Output leakage ILKG 1 All
current 2/ 2, 3
Input resistance RREF 1, 2, 3 All 6
Input resistance
RREF Measuring at VREFA, B, C, D 1, 2, 3 All
match pins
Digital input high VIH 1, 2, 3 All 2.4
Digital input low VIL 1, 2, 3 All
Input current IIN VIN = 0 V or VDD 1 All
2, 3
Digital output low VOL ISINK = 1.6 mA 1, 2, 3 All
Digital output high VOH ISOURCE = 400
A 1, 2, 3 All 4
Supply current IDD Digital inputs = VIL or VIH 1 All
Digital inputs = 0 V or VDD
Digital inputs = VIL or VIH 2, 3
Digital inputs = 0 V or VDD
Input capacitance CIN See 4.3.1c 4 All
Functional test See 4.3.1d 7, 8 All
Write to data strobe tDS1 3/ 9, 10, 11 All 90
time 4/ or
tDS2
Data valid to strobe tDSU 3/ 9, 10, 11 All 150
set-up time 4/
Data valid to strobe tDH 3/ 9 All 10
hold time 10, 11 10
4/
See footnotes at end of table.
Unit
Max
0.25 LSB
0.50
0.50 LSB
1.0
1.0 LSB
0.001 %
%
30 nA
100
14 k
1.0 %
V
0.8 V
1.0
A
10.0
0.4 V
V
1.0 mA
0.05
1.5
0.05
8 pF
ns
ns
ns
STANDARD
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
SIZE
A 5962-89678
REVISION LEVEL
A SHEET 5
DSCC FORM 2234
APR 97
TABLE I. Electrical performance characteristics - Continued.
Conditions
-55
C
TA
+125
C Group A Device Limits
Test Symbol VOUT1 = VOUT2 = 0 V subgroups type
VDD = +5 V;
VREF =
10 V
unless otherwise specified
Min
DAC select to strobe tAS 3/ 9 All 0
set-up time 10, 11 0
4/
DAC select to strobe tAH 3/ 9 All 0
hold time 10, 11 0
4/
Write select to strobe tWSU 3/ 9 All 0
set-up time 10, 11 0
4/
Write select to strobe tWH 3/ 9 All 0
hold time 10, 11 0
4/
Read to data strobe tRDS 3/ 9 All 220
width 10, 11 350
4/
Data strobe to output tC0 3/ 9 All 320
valid time 10, 11 430
4/
Output data to t0TD 3/ 9 All 200
deselect time 10, 11 270
4/
Read select to strobe tRSU 3/ 9 All 0
setup time 10, 11 0
4/
Read select to strobe tRH 3/ 9 All 0
hold time 10, 11 0
4/
1/
VDD =
10%.
2/ All digital inputs = 0 V.
3/ See figure 4.
4/ Subgroups 10 and 11, if not tested, shall be guaranteed to the limits specified in table I.
Unit
Max ns
ns
ns
ns
ns
ns
ns
ns
ns
STANDARD
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
SIZE
A 5962-89678
REVISION LEVEL
A SHEET 6
DSCC FORM 2234
APR 97
Device type 01 and 02
Case outline X
Terminal number Terminal symbol
1 VDD
2 VREFA
3 RFBA
4 IOUT1A
5 OUT2A
I OUT2B
I
6 IOUT1B
7 RFBB
8 VREFB
9 DB0(LSB)
10 DB1
11 DB2
12 DB3
13 DB4
14 DB5
15 DB6
16 DB7(LSB)
17 A B
18 R W
19 DS1
20 DS2
21 VREFD
22 RFBD
23 IOUT1D
24 OUT2C
I OUT2D
I
25 IOUT1C
26 RFBC
27 VREFC
28 DGND
FIGURE 1. Terminal connections.
STANDARD
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
SIZE
A 5962-89678
REVISION LEVEL
A SHEET 7
DSCC FORM 2234
APR 97
CONTROL LOGIC
MODE
DS1 DS2 A B R W
L H H L WRITE
L H L L WRITE
H L H L WRITE
H L L L WRITE
L H H H READ
L H L H READ
H L H H READ
H L L H READ
L L H L WRITE
L L L L WRITE
H H X X HOLD
L L H H HOLD
L L L H HOLD
L = Low
H = High
X = Don’t care
FIGURE 2. Truth table.
DAC
A
B
C
D
A
B
C
D
A & C
B & D
A/B/C/D
A/B/C/D
A/B/C/D
STANDARD
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
SIZE
A 5962-89678
REVISION LEVEL
A SHEET 8
DSCC FORM 2234
APR 97
FIGURE 3. Functional diagram.
STANDARD
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
SIZE
A 5962-89678
REVISION LEVEL
A SHEET 9
DSCC FORM 2234
APR 97
FIGURE 4. Timing diagram.
STANDARD
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
SIZE
A 5962-89678
REVISION LEVEL
A SHEET 10
DSCC FORM 2234
APR 97
TABLE II. Electrical test requirements.
MIL-STD-883 test requirements Subgroups
(in accordance with
MIL-STD-883, method 5005,
table I)
Interim electrical parameters 1
(method 5004)
Final electrical test parameters 1*, 2, 3, 7, 8
(method 5004)
Group A test requirements 1, 2, 3, 4, 7, 8, 9, 10**, 11**
(method 5005)
Groups C and D end-point 1
electrical parameters
(method 5005)
* PDA applies to subgroup 1.
** Subgroups 10, and 11, if not tested shall be
guaranteed to the limits specified in table I herein.
4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-STD-
883 including groups A, B, C, and D inspections. The following additional criteria shall apply.
4.3.1 Group A inspection.
a. Tests shall be as specified in table II herein.
b. Subgroups 5 and 6 in table I, method 5005 of MIL-STD-883 shall be omitted.
c. Subgroup 4 (CIN measurement) shall be measured only for the initial test and after process or design changes which
may affect input capacitance.
d. Subgroups 7 and 8 shall include verification of the truth table.
4.3.2 Groups C and D inspections.
a. End-point electrical parameters shall be as specified in table II herein.
b. Steady-state life test conditions, method 1005 of MIL-STD-883.
(1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision
level control and shall be made available to the preparing or acquiring activity upon request. The test circuit
shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent
specified in test method 1005 of MIL-STD-883.
(2) TA = +125
C, minimum.
(3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
STANDARD
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
SIZE
A 5962-89678
REVISION LEVEL
A SHEET 11
DSCC FORM 2234
APR 97
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
prepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus when a system application
requires configuration control and the applicable SMD. DSCC will maintain a record of users and this list will be used for
coordination and distribution of changes to the drawings. Users of drawings covering microelectronics devices (FSC 5962)
should contact DSCC-VA, telephone (614) 692-0544.
6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43216-5000, or telephone
(614) 692-0547.
6.6 Approved sources of supply. Approved sources of supply are listed in MIL-HDBK-103. The vendors listed in MIL-
HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and accepted
by DSCC-VA.
STANDARD
MICROCI RCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
SIZE
A 5962-89678
REVISION LEVEL
A SHEET 12
DSCC FORM 2234
APR 97
STANDARD MICROCIRCUIT DRAWI NG BULLETIN
DATE: 01-08-03
Approved sources of supply for SMD 5962-89678 are listed below for immediate acquisition information only and
shall be added to MIL-HDBK-103 and QML-38535 during the next revision. MIL-HDBK-103 and QML-38535 will be
revised to include the addition or deletion of sources. The vendors listed below have agreed to this drawing and a
certificate of compliance has been submitted to and accepted by DSCC-VA. This bulletin is superseded by the next
dated revision of MIL-HDBK-103 and QML-38535.
Standard Vendor Vendor
microcircuit drawing CAGE similar
PIN 1/ number PIN 2/
5962-8967801XA 24355 DAC8408AT/883
5962-8967802XA 24355 DAC8408BT/883
1/ The lead finish shown for each PIN representing
a hermetic package is the most readily available
from the manufacturer listed for that part. If the
desired lead finish is not listed contact the vendor
to determine its availability.
2/ Caution. Do not use this number for item
acquisition. Items acquired to this number may not
satisfy the performance requirements of this drawing.
Vendor CAGE Vendor name
number and address
24355 Analog Devices, Inc.
Rt. 1 Industrial Park
P.O. Box 9106
Norwood, Ma. 02062
Point of Contact:
1500 Space Park Dr.
P.O. Box 58020
Santa Clara, Ca. 95050-8020
The information contained herein is disseminated for convenience only and the
Government assumes no liability whatsoever for any inaccuracies in the
information bulletin.