Datasheet
I/O Modules
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.
DR OUTPUT MODULES
•
DIN Rail Mountable Single Point Output Modules (35mm DIN)
•
Plug into mounting boards for 0.6" modules
•
Zero Voltage Turn-On for AC Modules
•
4kV Optical isolation with LED Indicator
•
UL Recognized, CSA Certified, CE Compliant
•
Industry standard Color Coding Black (AC Output) Red (DC Output)
•
Barrier Strips Accept 14 to 28 AWG Wire.
SPECIFICATIONS
Input
42CDO-RD5CDO-RDCAO-RDrebmuN traP
Nominal Voltage [VDC] 5-24 5.0 24.0
Minimum Voltage [VDC] 3.7 3.5 18.0
Maximum Voltage [VDC] 32 8.0 32.0
Drop-out Voltage [VDC] 1.0 1.0 1.0
Maximum Current [mA] (2) 18 18 13
Resistance [Ohms] (3) NA 250 2000
Output
Nominal Line Voltage 240 VAC 5-48 VDC 5-48 VDC
Minimum Line Voltage 12 VAC 3 VDC 3 VDC
Maximum Line Voltage 280 VAC 60 VDC 60 VDC
Max Off-State Voltage (4) 600 Vpeak 60 VDC 60 VDC
Max Off-State Leakage (5) 0.1mArms 10 uA 10 uA
Static Off-State dv/dt (6) 200 V/usec N/A N/A
Maximum Rated On-State Current (7) 5.0 Arms 3.0 A 3.0 A
Minimum On-State Current 50 mArms 10 mA 10 mA
Max Surge Current (8) 250 Apeak 5.0 A 5.0 A
On-State Voltage Drop or Resistance (9) 1.6 V 1.6 V 1.6 V
Horse Power Rating (10) 1/2 H.P. N/A N/A
Fuse (11) 5 5 5
Maximum Turn-On Time [msec] (12) 8.33 0.1 0.1
Maximum Turn-Off Time [msec] (12) 8.33 0.75 0.75
Input/Output Isolation Voltage (13) 4000 Vrms 4000 Vrms 4000 Vrms
Input/Output Capacitance 8 pF 8 pF 8 pF
Operating Temperature Range -30 to 80°C -30 to 80°C -30 to 80°C
Storage Temperature Range -40 to 80°C -40 to 80°C -40 to 80°C
Line Frequency Range 47 to 63 Hz DC DC
Weight 1.1 oz. (31.2g) 1.1 oz. (31.2g) 1.1 oz. (31.2g)
General Notes:
(1)
Specifications apply to an ambient temperature of -30 to 80 °C unless otherwise noted.
(2)
At nominal input voltage, without external LED status indicator.
(3)
+/-10% at 25°C.
(4)
Maximum 1 minute duration for OAC modules when applied as a DC voltage rather than a peek AC voltage.
(5)
At maximum line voltage, 25°C for OAC modules, and 80°C for ODC modules.
(6)
Minimum DV/DT per EIA/NARM RS433, method RS397, DV/DT ratings do not apply to DC output models
(7)
At 40°C, derate OAC modules 58 mA/°C to 80°C, derate ODC. ODCxMC and ODCxML modules 50 mA/°C
to 80°C. CSA rating of OAC modules is 3.0 Arms at 40°C.
(8)
At 25°C for 1 second maximum duration: 1 AC cycle for AC modules, 1 second for DC modules.
(9)
At maximum rated on-state current and 25°C.
(10)
1/3 H.P. at 240 VAC, 1/8 H.P. at 120 VAC.
(11)
Fuse is BUSS # PCE5.
(12)
At maximum line voltage, maximum rated output current, nominal input voltage and 25°C. Switching speed
of OAC modules is based upon 60 Hz line frequency.
(13)
At 25°C for 1 second maximum duration.
(1)