Bussmann(R) 1000-4000A FWA 130V (R) Electrical Characteristics Ordering Information I2t (A2 Sec) Rated Current Clearing Watts Part Carton RMS-Amps Pre-arc at 130V Loss Number Qty. 1000 170000 460000 60 FWA-1000AH ______________________________________________________________________________________ Type Dimensions Curves Carton Weight (lbs) Figure Number See Page or (BIF #) 3.3 Fig. 1 1200 270000 730000 70 FWA-1200AH ______________________________________________________________________________________ 1500 520000 1400000 78 FWA-1500AH ______________________________________________________________________________________ FWA 2000 860000 2400000 108 FWA-2000AH 130V ______________________________________________________________________________________ 2500 1500000 4100000 130 FWA-2500AH ______________________________________________________________________________________ 1 3000 2100000 5700000 150 FWA-3000AH ______________________________________________________________________________________ 4000 3400000 9200000 257 FWA-4000AH 35785301 ______________ Fig. 2 n Interrupting rating 200kA RMS Symmetrical. n Watts loss provided at rated current. n (130 Vdc/Interrupting Rating 50kA) U.L. Recognition on 1000 through 2000 amperes. 1 kg = 2.2 lbs 1 lb = 0.45 kg Electrical Characteristics Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K , given as a function of applied working voltage, E g , (RMS). Arc Voltage This curve gives the peak arc voltage, U L , which may appear across the fuse during its operation as a function of the applied working voltage, E g , (RMS) at a power factor of 15%. 1.5 K Power Losses Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current . The correction factor, K p , is given as a function of the RMS load current, Ib , in % of the rated current . 1.0 Kp 0.8 UL 1.0 0.6 0.5 300 0.4 0.5 0.2 0.3 0.2 0.15 26 7-11-01 0.3 200 100 Eg Eg 65 104 SB01191 130 50 100 Ib 0.1 150 30 40 50 60 70 80 90 100% Form No. FWA 130 Page 1 of 2 BIF Doc #720001 Bussmann(R) FWA 130V 1000-4000A (R) Dimensions Fig. 1: 1000-3000 Amp Range Fig. 2: 4000 Amp Range 1.875 1.875 D B B C Order # FWA-1000AH-2000AH FWA-2500AH-3000AH FWA-4000AH Fig. 1 1 2 B 2.0 3.0 3.5 C 1.0 1.5 1.5 D -- -- 1.5 C Thread Depth Tapped *-24 TM Tapped TM-20 TM Tapped TM-20 TM Dimension in inches. 1mm = 0.0394 1 = 25.4mm The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 7-11-01 SB01191 Form No. FWA 130 Page 2 of 2 BIF Doc #720001