103
For Most Recent Data, Consult the Coto Technology Website: www.cotorelay.com 6 E-mail: info@cotorelay.com
RI-25 Series Dry Reed Switch
Operating and Storage Temperature
Operating ambient temperature; min: -55°C; max:
+125°C. Storage temperature; min: -55°C; max:
+125°C. Note: Temperature excursions up to 150°C
may be permissible. For more information contact your
nearest Coto Technology sales office.
Soldering
The switch can withstand soldering heat in accordance
with “IEC 68-2-20”, test Tb, method 1B: solder bath at
350 ±10°C for 3.5 ±0.5 s. Solderability is tested in
accordance with “IEC 68-2-20”, test Ta, method 3:
solder globule temperature 235°C; ageing Ib: 4 hours
steam.
Welding
The leads can be welded
Mounting
The leads should not be bent closer than 1 mm to the
glass-to-metal seals. Stress on the seals should be
avoided. Care must be taken to prevent stray magnetic
fields from influencing the operating and measuring
conditions.
ancy and reliability data. Further information is avail-
able on request.
Mechanical Data
Contact arrangement is normally open; lead finish is
tinned; net mass is approximately 190 mg; and can be
mounted in any position.
Shock
The switches are tested in accordance with “IEC 68-2-
27”, test Ea (peak acceleration 150 G, half sinewave;
duration 11 ms). Such a shock will not cause an open
switch (no magnetic field present) to close, nor a switch
kept closed by an 80 AT coil to open.
Vibration
The switches are tested in accordance with “IEC 68-2-
6”, test Fc (acceleration 10 G; below cross-over fre-
quency 57 to 62 Hz; amplitude 0.75 mm; frequency
range 10 to 2000 Hz, duration 90 minutes). Such a
vibration will not cause an open switch (no magnetic
field present) to close, nor a switch kept closed by an
80 AT coil to open.
Mechanical Strength
The robustness of the terminations is tested in accor-
dance with “IEC 68-2-21”, test Ua1 (load 40 N).
Model Number
RI-25AAA RI-25AA RI-25A RI-25B RI-25C
Parameters Test Conditions Units
Operating Characteristics
Operate Range AT 8-16 14-23 18-32 28-52 46-70
Release Range AT 4-14 7.5-17.5 8-22 12-29 16-32
Operate Time - including bounce (typ.) (energization) ms 0.25(20 AT) 0.25(29 AT) 0.25(40 AT) 0.25(65 AT) 0.25(88 AT)
Bounce Time (typ.) (energization) ms 0.05(20 AT) 0.15(29 AT) 0.15(40 AT) 0.15(65 AT) 0.15(88 AT)
Release Time (max) (energization)
µ
s70(20 AT) 30(29 AT) 30(40 AT) 30(65 AT) 30(88 AT)
Resonant Frequency (typ.) Hz 5100 5100 5100 5100 5100
Electrical Characteristics
Switched Power (max) W 10 15 15 25 25
Switched Voltage DC (max) V 200 200 200 200 200
Switched Voltage AC, RMS value (max) V 140 140 140 140 140
Switched Current DC (max) mA 750 1000 1000 1000 1000
Switched Current AC, RMS value (max) mA 750 1000 1000 1000 1000
Carry Current DC; AC, RMS value (max) A 1.5 1.75 2.5 2.75 3.0
Breakdown Voltage (min) V 200 275 325 400 500
Contact Resistance (initial max) (energization) m
Ω
100 (20 AT) 100 (25 AT) 100 (30AT) 100 (40 AT) 100 (40 AT)
Contact Resistance (initial typ.) (energization) m
Ω
70 (20 AT) 70 (25 AT) 70 (30 AT) 70 (40 AT) 70 (40 AT)
Contact Capacitance (max) without test coil pF 0.3 0.3 0.25 0.25 0.25
Insulation Resistance (min) RH
≤
45% M
Ω
10
6
10
6
10
6
10
6
10
6