Parameter Ratings Units
Peak Blocking Voltage 400 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1100 mW
Total Package Dissipation 2550 mW
Isolation Voltage, Input to Output, 60 sec. 5000 Vrms
ESD Rating, Human Body Model 8 kV
Operational Temperature -40 to +85 ºC
Storage Temperature -40 to +125 ºC
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 3.00 mW / ºC
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous 1-I
L- - 140
mA
Peak t=10ms ILPK - - 400
On-Resistance 2IF=2mA, IL=140mA RON -1422
Off-State Leakage Current VL=400VPILEAK -- 1 A
Switching Speeds
Turn-On IF=10mA, VL=10V ton - 0.525 1 ms
Turn-Off toff - 0.42 1
Output Capacitance IF=0mA, VL=50V, f=1MHz COUT -13 - pF
Input Characteristics
Input Control Current to Activate 3IL=140mA IF- 0.4 2 mA
Input Control Current to Deactivate - IF0.2 - - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR--10 A
Common Characteristics
Input to Output Capacitance - CI/O -3 - pF
1 Load current derates linearly from 140mA @ 25ºC to 70mA @ 85ºC.
2 Measurement taken within one second of turn-on time.
3 For applications requiring high-temperature operation (T