Only One Name Means ProTek’Tion™

 




The PP-SM Series are thyristor surge suppression (TSS) devices designed to protect telecommunicaon equipment
against lightning and transients induced by AC power lines. These devices can be used on central oce equipment,
PBX, DSU, OCU and other telecommunicaon equiment/systems. The bidireconal conguraon provides protecon
for both posive and negave transients and the discrete surface mount package allows for individual placement of
the device on line cards or other locaons where mulple component devices do not oer the versale in board trace
layout.
This series can be used to provide protecon in accordance with industry standards such as FCC Part 68, ANSI C62.41,
UL 1459, GR-1089-CORE, IEC 61000-2, IEC 61000-4 and IEC 61000-4-5 requirements.
Compable with IEC 61000-4-2 (ESD): Air 15kV, Contact 8kV
Compable with IEC 61000-4-4 (EFT): 40A, 5/50ns
Compable with IEC 61000-4-5 (Surge): 95A, 8/20µs - L4(Line-
Ground), 48A - L4(Line-Line) & 83A - L2(Power)
FCC Part 68, UL 1459, Bellcore 1089 & ITU-K.20/K.21 Compliant
UL File Recognion #E208219
Peak O-State Voltage from 25 to 300 Volts
Surge Current Capability (See Table 1)
ESD Protecon > 25 kilovolts
Low Capacitance for T1/E1 Trunk & Line Card Applicaons
Bidireconal Conguraon
RoHS Compliant
REACH Compliant

Molded Plasc DO-214AA Package
Approximate Weight: 2.5 grams
Lead-Free Pure-Tin Plang (Annealed)
Solder Reow Temperature:
Pure-Tin - Sn, 100: 260-270°C
Flammability Rang UL 94V-0
12mm Tape and Reel per EIA Standard 481

T1/E1 Trunk & Line Cards
SLIC Line Card
DBX Branch Exchange Switches
FCC Part 68 Customer Premise Equipment
Line Interface Modem
xDSL Architecture Interface


 























SA 150 150 100 50 50 20 500 2000
SB 300 300 150 100 80 32 500 2000
SC 500 400 200 200 100 60 500 2000

1. Crical rate of rise for On-State Current (di/dt) and O-State Voltage (dv/dt).
DEVICE SYMBOL
BIDIRECTIONAL
Only One Name Means ProTek’Tion™

 




   
Surge Current - 50/60Hz (SC Series) ITSM 60 Amps
Juncon Temperature TA-40 to 150 °C
Storage Temperature TSTG -55 to 150 °C
Thermal Resistance (Juncon) - SA & SB Series RQJC 28 °C/Wa
Thermal Resistance (Juncon) - SC Series RQJC 26 °C/Wa
Thermal Resistance (Ambient) - SA & SB Series RQJA 90 °C/Wa
Thermal Resistance (Ambient) - SC Series RQJA 85 °C/Wa


tf
Peak Value IPP
TEST
WAVEFORM
PARAMETERS
tf = 10µs
td = 1000µs
td = t/(IPP/2)
e-t





IPP
ITSM
IT
IS
IH
IDRM
VTVDRM
VS










PPxxxxSA
PPxxxxSC
PPxxxxSB
Only One Name Means ProTek’Tion™

 















































PP0640SA GC 58 77 150 800 5 4 2.2 60
PP0720SA GD 65 88 150 800 5 4 2.2 60
PP0800SA GE 75 98 150 800 5 4 2.2 60
PP1100SA GF 90 130 150 800 5 4 2.2 60
PP1300SA GG 120 160 150 800 5 4 2.2 40
PP1500SA GH 140 180 150 800 5 4 2.2 40
PP1800SA GI 160 220 150 800 5 4 2.2 40
PP2300SA GJ 190 260 150 800 5 4 2.2 30
PP2600SA GK 220 300 150 800 5 4 2.2 30
PP3100SA GL 275 350 150 800 5 4 2.2 30
PP3500SA GM 300 400 150 800 5 4 2.2 30
PP0300SB GN 25 40 50 800 5 4 2.2 110
PP0640SB GP 58 77 150 800 5 4 2.2 60
PP0720SB GQ 65 88 150 800 5 4 2.2 60
PP0800SB GR 75 98 150 800 5 4 2.2 60
PP1100SB GS 90 130 150 800 5 4 2.2 60
PP1300SB GT 120 160 150 800 5 4 2.2 40
PP1500SB GU 140 180 150 800 5 4 2.2 40
PP1800SB GV 160 220 150 800 5 4 2.2 40
PP2300SB GW 190 260 150 800 5 4 2.2 30
PP2600SB GX 220 300 150 800 5 4 2.2 30
PP3100SB GY 275 350 150 800 5 4 2.2 30
PP3500SB GZ 300 400 150 800 5 4 2.2 30
PP0640SC HC 58 77 150 800 5 4 2.2 120
PP0720SC HD 65 88 150 800 5 4 2.2 120
PP0800SC HE 75 98 150 800 5 4 2.2 120
PP1100SC HF 90 130 150 800 5 4 2.2 120
PP1300SC HG 120 160 150 800 5 4 2.2 80
PP1500SC HH 140 180 150 800 5 4 2.2 80
PP1800SC HI 160 220 150 800 5 4 2.2 80
PP2300SC HJ 190 260 150 800 5 4 2.2 60
PP2600SC HK 220 300 150 800 5 4 2.2 60
PP3100SC HL 275 350 150 800 5 4 2.2 60
PP3500SC HM 300 400 150 800 5 4 2.2 60

1. Capacitance imblance between posive and negave polaries is typically < 15pF.
Only One Name Means ProTek’Tion™

 



































Only One Name Means ProTek’Tion™

 




The TSS (Thyristor Surge Suppressor) device is located across the p-to-ring aer a liming resistor and fuse combinaon. RTIP and RRING resistors are oponal de-
pending upon the TSS device selecon. Without the resistors, the PP3100SB/SC is recommended. However, with a resistance value of 7.5 Ohms for p and ring, the
PP3100SA is recommended. Digital signals may use a lower TSS device depending upon the total p to ring voltage range. Selecon of the TSS device, either PPxxxx-
SA or SB/SC is based upon the value of the p and ring resistors. For the Naonal Electric Code (NEC) arcle 800, it is recommended that at least one fuse be used in
the p or ring line for metallic surges. Fuses may be replaced with a suitable Posive Temperature Coecient (PTC) automac reseable current liming device.
To Protected
Equipment
TIP
RING
RTip
RRing
Fuse

There are two TSS devices, one located from p-to-ground and one ring-to-ground. For standard analog signals, the PP3100SA is recommended with a typical resistor
value for p and ring of 15 Ohms. The PP3100SB/SC is recommended for resistor values of 7.5 Ohms each. The Naonal Electric Code (NEC) arcle 800 requires two
fuse elements when connecng to ground. Fuses or a suitable Posive Temperature Coecient (PTC) automac reseable current liming device may be used. The
purpose of this circuit is to limit AC power current from geng on the ground line causing any safety hazard.
To Protected
Equipment
TIP
RING
RTip
RRing
Only One Name Means ProTek’Tion™

 




Three equal TSS devices are used in this applicaon for metallic (p-to-ring) and longitudinal (p-to-ground and ring-to-ground) protecon. For analog signals, the
PP3100SB/SC is recommended. With a resistance value of 15 Ohms for the p and ring resistors, the PP3100SA may be used. The Naonal Electric Code (NEC) arcle
800 requires two fuse elements when connecng to ground. Fuses or a suitable Posive Temperature Coecient (PTC) automac reseable current liming device
may be used. This circuit is recommended for protecon against the Bellcore requirement: First Level Lightning Surge Tests (Telecommunicaons Port), document #
GR-1089-CORE.
To Protected
Equipment
TIP
RING
RTip
RRing

Circuit board layout is crical for electromagnec compability protecon. The following guidelines are recommended:
The protecon device should be placed near the input terminals or connectors, the device will divert the transient current
immediately before it can be coupled into the nearby traces.
The path length between the TVS device and the protected line should be minimized.
All conducve loops including power and ground loops should be minimized.
The transient current return path to ground should be kept as short as possible to reduce parasic inductance.
Ground planes should be used whenever possible. For mullayer PCBs, use ground vias.
Only One Name Means ProTek’Tion™

 




  
   
A 1.96 2.21 0.077 0.087
B 4.06 4.57 0.160 0.180
C 3.30 3.94 0.130 0.155
D 2.00 2.50 0.079 0.098
E 0.76 1.52 0.030 0.060
F 0.10 0.20 0.004 0.008
G 5.08 5.59 0.200 0.220
H 0.15 031 0.006 0.012

1. Dimensions are exclusive of mold ash and metal burrs.

  
   
A 2.10 - 0.083 -
B 1.27 - 0.050 -
C - 2.69 - 0.106
D 1.27 - 0.083 -
A C
B
Polarity Band
D
G
F
E
H
A
B C D
Only One Name Means ProTek’Tion™

 




     
PPxxxxSA/SB/SC -LF -T 3,000 13” n/a
This device is only available in a Lead-Free conguraon.
User Direcon of Feed
t
K0
A0 P
D
P0
E
B0
F
W
10 Pitches Cumulave
Tolerance on tape ± 0.2

 
     
330mm (13”) 12mm 3.79 ± 0.15 5.72 ± 0.15 2.46 ± 0.30 1.55 ± 0.05 1.75 ± 0.10 5.5 ± 0.05 12.00 ± 0.30 4.00 ± 0.10 8.00 ± 0.10 0.25 ± 0.10

1. Dimensions are in millimeters.
2. Surface mount product is taped and reeled in accordance with EIA-481.
3. Sux - T = 13” Reel - 3,000 pieces per 12mm tape.
4. Marking on Part - marking code (see page 2) and logo.
Package outline, pad layout and tape specicaons per document number 06030.R2 2/11.
Only One Name Means ProTek’Tion™

 



COPYRIGHT © ProTek Devices 2000 - This literature is subject to all applicable copyright laws and is not for resale in any manner.
SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteriscs described herein without noce.
DESIGN CHANGES: ProTek reserves the right to disconnue product lines without noce and that the nal judgement concerning selecon and specicaons is the buyer’s and that in furnishing engineering
and technical assistance. ProTek assumes no responsibility with respect to the selecon or specicaons of such products. ProTek makes no warranty, representaon or guarantee regarding the suitability of
its products for any parcular purpose, nor does ProTek assume any liability arising out of the applicaon or use of any product or circuit and specically disclaims any and all liability without limitaon special,
consequenal or incidental damages.
LIFE SUPPORT POLICY: ProTek Devices products are not authorized for use in life support systems without wrien consent from the factory.

In business more than 20 years, ProTek Devices™ is a privately-held company located in Tempe, Arizona, that oers a product line of tran-
sient voltage suppressors (TVS); avalanche breakdown diodes; steering diode TVS arrays and other surge suppressor component products.
These TVS devices protect electronic systems from the eects of lightning, electrostac discharge (ESD), nuclear electromagnec pulses
(NEMP), inducve switching and EMI / RFI. ProTek Devices also oers high performance interface and linear products that include analog
switches; mulplexers; LED drivers; audio control ICs; RF and related high frequency products. The analog devices work in a host of con-
sumer; industrial; automove and other applicaons.


2929 South Fair Lane
Tempe, Arizona 85282
USA

General: 602-431-8101
Sales: & Markeng: 602-414-5109
Customer Service: 602-414-5114
Product Technical Support: 602-414-5107

General: 602-431-2288

Sales: sales@protekdevices.com
Customer Service: service@protekdevices.com
Technical Support: support@protekdevices.com

8 Ubi Road 2, #06-19
Zervex
Singapore - 408538
Tel: +65-67488312
Fax: +65-67488313

www.protekdevices.com