5 Non-Ventilated Automation Transformers Automation Transformers - Non-Ventilated 50 VA to 45 kVA SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments. Encapsulation and rugged UL Listed/NEMA Type 3R enclosures protect the transformer from dust, moisture, and provide extra shock and vibration resistance. SolaHD transformers fully comply with the latest addition of the National Electrical Code for Class I, Division 2, Group A, B, C and D locations when installed in compliance with NEC 501.100 (B). Features Single Phase: .05 - .250 kVA * UL Listed/NEMA Type 3R non encapsulated enclosure for indoor and outdoor service * Low temperature rise, UL Class 130oC insulation system, 80oC temperature rise under full load * Conduit knockouts for side entry into wiring compartment * Copper lead wire terminations Single Phase: 0.500 - 25 kVA Three Phase: 3 - 45 kVA * UL Listed/NEMA Type 3R encapsulated enclosure for indoor and outdoor service * Electrostatically shielded for quality power on sizes 1 kVA and larger * UL Class 200oC insulation system, 115C temperature rise under full load * Conduit knockouts for side entry into wiring compartment * Copper lead wire terminations * .500 - 45 kVA units are encapsulated with electrical grade silica and epoxy for industrial applications E25872 E77014 Accessories and Optional Design Styles * Stainless Steel Enclosures * Copper Wound designs * UL Listed/NEMA Type 4, 4X or 12 Encapsulated Enclosures * Low temperature designs available Related Products * Some SolaHD DC power supplies are available with Class I, Division 2 ratings or encapsulation. * Surge Protective Devices Certifications and Compliances * Listed: E25872, E77014 - UL 1561 or UL 506 - CSA C22.2 No. 47 or No. 66 Note: Weights and dimensions may change and should not be used for construction purposes. 224 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 5 Non-Ventilated Automation Transformers Selection Table: Single Phase Group 1: 240 x 480 Primary, 120/240 Secondary, 60 Hz kVA Catalog Number Catalog Number Group I Group II Rolled Steel Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style * Elec Conn * Primary Amps Secondary Amps 6.00 (152.4) 4.00 (101.6) 3.00 (76.2) 3.00 (1.36) 2 15 .208/.104 0.416/0.208 6.00 (152.4) 6.00 (152.4) 4.00 (101.6) 3.00 (76.2) 3.00 (1.36) 2 15 .312/.156 0.625/0.312 4.00 (101.6) 3.00 (76.2) 4.00 (1.81) 2 15 .417/.208 0.833/0.417 Non-Encapsulated .050 HS1B50 .075 HS1B75 .100 HS1B100 .150 HS1B150 8.00 (203.2) 4.00 (101.6) 4.00 (101.6) 5.00 (2.27) 2 15 .625/.313 1.25/.625 .250 HS1B250 8.00 (203.2) 4.00 (101.6) 4.00 (101.6) 8.00 (3.63) 2 15 1.04/.512 2.08/1.04 0.5 HS1F500B HSS1F500B 10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 22.0 (9.98) 3 15 2.08/1.04 4.16/2.08 0.75 HS1F750B HSS1F750B 10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 27.0 (12.25) 3 15 3.13/1.56 6.25/3.13 N/A Encapsulated 1 HS1F1BS HSS1F1BS 10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 28.0 (12.70) 3 16 4.17/2.08 8.33/4.17 HS1F1.5AS HSS1F1.5AS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 38.0 (17.24) 4 16 6.25/3.13 12.5/6.25 2 HS1F2AS HSS1F2AS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 45.0 (20.42) 4 16 8.33/4.17 16.7/8.33 3 HS5F3AS HSS5F3AS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 55.0 (24.95) 4 17 12.5/6.25 25.0/12.5 1.5 HS5F5AS HSS5F5AS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 131.0 (59.42) 4 17 20.8/10.4 41.6/20.8 7.5 5 HS5F7.5AS HSS5F7.5AS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 156.0 (70.76) 4 18 31.3/15.6 62.5/31.3 10 HS5F10AS HSS5F10AS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 156.0 (70.76) 4 18 41.7/20.8 83.3./41.7 15 HS5F15AS HSS5F15AS 30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 549.0 (249.02) 4 18 62.5/31.2 125.0/62.5 25 HS5F25AS HSS5F25AS 30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 637.0 (288.94) 4 18 104.0/52.0 208.0/104.0 Group 2: 600 Volt Primary, 120/240 Secondary, 60 Hz kVA Catalog Number Group 1 Rolled Steel .100 HS10B100 Catalog Number Group 2 Stainless Steel Height in (mm) Width in (mm) 6.00 (152.4) 4.00 (101.6) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style * Elec Conn * Primary Amps Secondary Amps 4.00 (1.81) 2 21 0.167 .833/.417 Non-Encapsulated 3.00 (76.2) .150 HS10B150 8.00 (203.2) 4.00 (101.6) 4.00 (101.6) 5.00 (2.27) 2 21 0.25 1.25/.625 .250 HS10B250 8.00 (203.2) 4.00 (101.6) 4.00 (101.6) 8.00 (3.63) 2 21 0.417 2.08/1.04 HS10F500B 10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 22.0 (9.98) 3 21 0.833 4.16/2.08 N/A Encapsulated .500 HSS10F500B .750 HS10F750B HSS10F750B 10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 23.0 (10.43) 3 21 1.25 6.25/3.13 1 HS10F1BS HSS10F1BS 10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 28.0 (12.70) 3 21 1.67 8.33/4.17 1.5 HS10F1.5AS HSS10F1.5AS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 38.0 (17.24) 4 21 2.5 12.5/6.25 2 HS10F2AS HSS10F2AS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 60.0 (27.22) 4 21 3.33 16.7/8.33 3 HS10F3AS HSS10F3AS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 66.0 (29.94) 4 22 5.0 25.0/12.5 HS10F5AS HSS10F5AS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 100.0 (45.36) 4 22 8.3 41.6/20.8 7.5 5 HS10F7.5AS HSS10F7.5AS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 135.0 (61.23) 4 22 12.5 62.5/31.3 10 HS10F10AS HSS10F10AS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 150.0 (68.04) 4 22 16.7 83.3/41.7 * Note: Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section. Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 225 5 Non-Ventilated Automation Transformers Selection Table: Single Phase Group 3: 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz kVA Catalog Number Group 1 Rolled Steel Catalog Number Group 2 Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps @ 277 V Secondary Amps Encapsulated 1 HS12F1BS HSS12F1BS 10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 29.0 (13.15) 3 19 3.6 8.33/4.17 HS12F1.5AS HSS12F1.5AS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 40.0 (18.14) 4 20 5.4 12.5/6.25 2 HS12F2AS HSS12F2AS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 60.0 (27.22) 4 20 7.2 16.7/8.33 3 HS12F3AS HSS12F3AS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 66.0 (29.94) 4 20 10.8 25.0/12.5 HS12F5AS HSS12F5AS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 104.0 (47.17) 4 20 18.0 41.6/20.8 7.5 HS12F7.5AS HSS12F7.5AS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 135.0 (61.23) 4 20 27.1 62.5/31.3 10 HS12F10AS HSS12F10AS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 156.0 (70.76) 4 20 36.1 83.3/41.7 1.5 5 Group 4: Export 190/200/208/220/380/400/415/440 Volt Primary, 110/220 Secondary, 50/60 Hz Copper wound Export 200/208/230/400/415/460 Volt Primary, 115/230 Secondary, 50/60 Hz Copper wound Export 208/240/415/480 Volt Primary, 120/240 Secondary, 60 Hz only Copper wound kVA Catalog Number Catalog Number Group 1 Group 2 Rolled Steel Stainless Steel Height in (mm) Width in (mm) 6.00 (152.4) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps 2 Secondary Amps Encapsulated, Copper Wound 1 1.5 2 HS14F1BS HSS14F1BS 10.00 (254.0) 5.00 (127.0) 34.0 (15.42) 3 23 4.5/2.3 9.1/4.5 HS14F1.5BS HSS14F1.5BS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 40.0 (18.13) 4 24 6.8/3.4 13.6/6.8 HS14F2BS HSS14F2BS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 60.0 (27.21) 4 24 9.1/4.5 18.2/9.1 73.0 (33.11) 4 24 13.6/6.8 27.3/13.6 3 HS14F3BS HSS14F3BS 12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 5 HS14F5BS HSS14F5BS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 100.0 (45.36) 4 24 22.7/11.4 45.5/22.7 HS14F7.5BS HSS14F7.5BS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 140.0 (63.50) 4 24 34.1/17.0 68.2/34.1 HSS14F10BS 17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 175.0 (79.38) 4 24 45.5/22.7 90.9/45.5 7.5 10 HS14F10BS Notes: 1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section. 2. Amperage calculated at 220/440 Volts on primary. UL Listed and CSA Certified. 240 & 480 V not available at 50 Hz. 226 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 5 Non-Ventilated Automation Transformers Selection Tables: Three Phase Group A: 480 Volt Primary, 208Y/120 Secondary, 60 Hz kVA 3 Catalog Number Group I Rolled Steel HT1F3AS Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps HTS1F3AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 105.0 (47.63) 4 27 3.6 8.3 16.00 (406.4) 9.00 (228.6) 110.0 (49.90) 4 27 7.2 16.6 Secondary Amps 6 HT1F6AS HTS1F6AS 13.00 (330.2) 9 HT1F9AS HTS1F9AS 17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 250.0 (113.40) 4 27 10.8 25.0 20.00 (508.0) 11.00 (279.4) 261.0 (118.39) 4 27 18.1 41.7 15 HT1F15AS HTS1F15AS 17.00 (431.8) 30 HT1F30AS HTS1F30AS 30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 696.0 (315.70) 4 27 36.1 83.4 HTS1F45AS 30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 844.0 (382.83) 4 27 54.2 125.0 45 HT1F45AS Group B: 208 Volt Primary, 208Y/120 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps Secondary Amps 9.00 (228.6) 97.0 (44.00) 4 26 7.2 8.3 3 HT3F3AS HTS3F3AS 13.00 (330.2) 16.00 (406.4) 6 HT3F6AS HTS3F6AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 141.0 (63.96) 4 26 14.4 16.6 9 HT3F9AS HTS3F9AS 17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12) 4 26 21.7 25.0 Group C: 480 Volt Primary, 240 Volt 120 Secondary with reduced capacity center tap, 60 Hz 2 kVA 3 Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) HT5F3AS HTS5F3AS 13.00 (330.2) 16.00 (406.4) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps Secondary Amps 9.00 (228.6) 105.0 (47.63) 4 28 3.6 7.2 6 HT5F6AS HTS5F6AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 110.0 (49.90) 4 28 7.2 14.4 9 HT5F9AS HTS5F9AS 17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 250.0 (113.40) 4 28 10.8 21.7 15 HT5F15AS HTS5F15AS 17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 305.0 (138.35) 4 28 18.1 36.1 30 HT5F30AS HTS5F30AS 29.00 (736.6) 25.00 (635.0) 12.00 (304.8) 698.0 (316.61) 4 28 36.1 72.2 45 HT5F45AS HTS5F45AS 29.00 (736.6) 25.00 (635.0) 12.00 (304.8) 876.0 (397.35) 4 28 54.2 108.3 Approx. Ship Weight lbs (kg) Design Style 1 Elec Conn 1 Primary Amps Secondary Amps Group D: 240 Volt Primary, 208Y/120 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) 3 HT6F3AS HTS6F3AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 97.0 (44.00) 4 25 7.2 8.3 6 HT6F6AS HTS6F6AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 141.0 (63.96) 4 25 14.4 16.6 9 HT6F9AS HTS6F9AS 17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12) 4 25 21.7 25.0 Notes: 1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section. 2. Refer to Capacity of Center Tap in Center Tap Delta Transformers at the beginning of this section. Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 227 5 Non-Ventilated Automation Transformers Selection Tables: Three Phase Group E: 480 Volt Primary, 380Y/220 Secondary, 60 Hz kVA 3 6 9 Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel Height in (mm) Width in (mm) Depth in (mm) Approx. Ship Weight lbs (kg) Design Style * Elec Conn * Primary Amps Secondary Amps HTS79F3AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 121.0 (54.88) 4 29 3.6 4.6 HT79F6AS HTS79F6AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 141.0 (63.96) 4 29 7.2 9.1 HT79F9AS HTS79F9AS 17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 255.0 (115.7) 4 29 10.8 13.6 HT79F3AS Group F: 600 Volt Primary, 208Y/120 Secondary, 60 Hz kVA Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel 3 HT7F3AS HTS7F3AS 6 HT7F6AS 9 HT7F9AS Depth in (mm) Approx. Ship Weight lbs (kg) Design Style * Elec Conn * Primary Amps Secondary Amps 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 116.0 (52.62) 4 30 2.9 8.3 HTS7F6AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 145.0 (65.77) 4 30 5.8 16.6 HTS7F9AS 17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 225.0 (115.67) 4 30 8.7 25.0 Ship Weight Approx. (lbs) Design Style * Elec Conn * Primary Amps Secondary Amps 3.6 Height in (mm) Width in (mm) Group G: 208 Volt Primary, 480Y/277 Secondary, 60 Hz Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel 3 HT84F3AS HTS84F3AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 97.0 (44.00) 4 31 8.3 6 HT84F6AS HTS84F6AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 141.0 (63.96) 4 31 16.6 7.2 9 HT84F9AS HTS84F9AS 17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12) 4 31 25.0 10.8 Ship Weight Approx. (lbs) Design Style * Elec Conn * Primary Amps Secondary Amps kVA Height in (mm) Width in (mm) Depth in (mm) Group H: 240 Volt Primary, 480Y/277 Secondary, 60 Hz Catalog Number Group I Rolled Steel Catalog Number Group II Stainless Steel 3 HT85F3AS HTS85F3AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 97.0 (44.00) 4 32 7.2 3.6 6 HT85F6AS HTS85F6AS 13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 141.0 (63.96) 4 32 14.4 7.2 9 HT85F9AS HTS85F9AS 17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12) 4 32 21.6 10.8 kVA Height in (mm) Width in (mm) Depth in (mm) * Notes: Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section. 228 Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. Non-Ventilated Automation Transformers 5 Design Styles D W H Style 2 - Non-Encapsulated W D H Style 3 - Encapsulated Style 4 - Encapsulated Customized Enclosures - Contact Technical Services Style 5 - Encapsulated Available for all encapsulated kVA sizes (For Type 4, 12 and 4X) Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 229 5 Non-Ventilated Automation Transformers Electrical Connections (Single Phase) 240 X 480 Volt Primary 120/240 Volt Secondary Taps: None H1 15 H2 H3 240 X 480 Volt Primary 120/240 Volt Secondary Taps: None H4 H1 H3 16 H2 240 X 480 Volt Primary 120/240 Volt Secondary Taps: 2, 21/2% FCAN & FCBN H2 H3 H4 H1 H4 17 H8 H5 H6 H7 SHIELD SHIELD X3 X1 X2 X3 X1 X4 X2 X4 X3 X1 X2 X4 Primary Voltage Interconnect 504 H4 to H5 Connect Lines to H1 & H8 Primary Voltage Interconnect Connect Lines to Primary Voltage Interconnect Connect Lines to 492 H3 to H5 H1 & H8 480 H2 to H3 H1 & H4 480 H2 to H3 H1 & H4 480 H3 to H6 H1 & H8 240 H1 to H3 H2 to H4 H1 & H4 240 H1 to H3 H2 to H4 H1 & H4 Secondary Voltage Interconnect Connect Lines to Secondary Voltage Interconnect Connect Lines to 240 X2 to X3 X1 & X4 240 X2 to X3 X1 & X4 120-0-120 X2 to X3 X2 to X1-X2-X4 120-0-120 X2 to X3 X2 to X1-X2-X4 120 X1 to X3 X2 to X4 X1 & X4 120 X1 to X3 X2 to X4 X1 & X4 HS1 Series HS1 Series 240 X 480 Volt Primary, 120/240 Volt Secondary Taps: 2, 21/2% FCAN; 4, 21/2% FCBN H1 H2 H3 H4 H5 H6 H7 H8 H9 18 H10 H3 H2 X3 X2 Connect Lines to 504 H5 to H6 H1 & H10 H1 & H8 240 H1 to H6 H3 to H8 H1 & H8 228 H1 to H7 H2 to H8 H1 & H8 Secondary Voltage Interconnect Connect Lines to 240 X2 to X3 X1 & X4 X2 to X3 X2 to 120-0-120 X1-X2-X4 X1 to X3 X2 to X4 120 X1 & X4 20 X3 X1 X2 H1 H2 H3 H4 H5 H6 H7 H8 X4 492 H4 to H6 H1 & H10 Primary Voltage Interconnect Connect Lines to 480 H4 to H7 H1 & H10 277 H2 to H3 H1 & H6 468 H3 to H7 H1 & H10 240 H2 to H3 H1 & H5 X1 Primary Voltage Interconnect Connect Lines to 277 H4 to H5 H1 & H8 240 H3 to H6 H1 & H8 208 H2 to H7 H1 & H8 120 H1 to H6 H3 to H8 H1 & H8 Secondary Voltage Interconnect Connect Lines to 240 X2 to X3 X1 & X4 120-0-120 X2 to X3 X2 to X1-X2-X4 120 X1 to X3 X2 to X4 X1 & X4 208 H2 to H3 H1 & H4 120 H1 to H3 H2 to H5 H1 & H5 Secondary Voltage Interconnect Connect Lines to 240 X2 to X3 X1 & X4 H1 & H10 120-0-120 X2 to X3 X2 to X1-X2-X4 H1 & H10 120 X1 to X3 X2 to X4 X1 & X4 456 H3 to H8 H1 & H10 444 H2 to H8 H1 & H10 432 H2 to H9 H1 & H10 252 H1 to H6 H5 to H10 H1 & H10 240 H1 to H7 H4 to H10 228 H1 to H8 H3 to H10 216 H1 to H9 H2 to H10 H1 & H10 Secondary Voltage Interconnect Connect Lines to 240 X2 to X3 X1 & X4 120-0-120 X2 to X3 X2 to X1-X2-X4 120 X1 to X3 X2 to X4 X1 & X4 HS5 Series 230 H1 to H5 H4 to H8 120/208/240/277 Volt Primary 120/240 Volt Secondary Taps: None SHIELD Interconnect 252 HS5 Series X4 Primary Voltage H1 & H8 H1 & H8 H4 H5 H6 SHIELD X1 H2 to H6 H2 to H7 19 120/208/240/277 Volt Primary 120/240 Volt Secondary Taps: None H1 468 456 HS12 Series (1 kVA only) SHIELD X3 = Earth Ground X2 X4 HS12 Series Note: Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject to change without notice. Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 5 Non-Ventilated Automation Transformers Electrical Connections (Single Phase) 600 Volt Primary, 120/240 Volt Secondary Taps: None 21 H1 H2 600 Volt Primary 120/240 Volt Secondary Taps: 2, 5% FCBN H1 H2 H3 H4 22 H5 H6 190/200/208/220/380/400/415/440 Volt Pri. 110/220 Volt Secondary Taps: None 23 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 SHIELD SHIELD X3 X1 X2 X4 X3 X1 X3 X1 Primary Voltage X2 X4 Interconnect Primary Voltage Interconnect Connect Lines to 600 H3 to H4 H1 & H6 570 H2 to H4 Connect Lines to 600 H1 & H2 540 Secondary Voltage Interconnect Connect Lines to 240 X2 to X3 X1 & X4 120-0-120 X2 to X3 X2 to m X1, X2 & X4 120 X1 to X3 X2 to X4 X1 & X4 H2 to H5 440 H5 to H6 H1 & H10 H1 & H6 415 H4 to H6 H1 & H9 400 H3 to H6 H1 & H8 380 H2 to H6 H1 & H7 220 H1 to H6 H5 to H10 H1 & H10 208 H1 to H6 H4 to H9 H1 & H9 200 H1 to H6 H3 to H8 H1 & H8 190 H1 to H6 H2 to H7 H1 & H7 Secondary Voltage Interconnect Connect Lines to 220 X2 to X3 X1 & X4 110-0-110 X2 to X3 X2 to X1, X2 & X4 110 X1 to X3 X2 to X4 X1 & X4 X2 to X3 X1 & X4 120-0-120 X2 to X3 X2 to X1-X2-X4 120 X1 to X3 X2 to X4 X1 & X4 24 H6 H7 H8 H9 H1 & H6 240 190/200/208/220/380/400/415/440 Volt Pri. 110/220 Volt Secondary Taps: None H2 H3 H4 H5 Connect Lines to Connect Lines to Note: 1 through 2 kVA units have electrostatic shielding. H1 Interconnect Interconnect HS10 Series X4 Primary Voltage Secondary Voltage HS10 Series X2 H10 HS14 Series (1 kVA only) SHIELD X1 Primary Voltage X3 X2 Interconnect X4 Connect Lines to 440 H5 to H6 H1 & H10 415 H4 to H7 H1 & H10 400 H3 to H8 H1 & H10 380 H2 to H9 H1 & H10 220 H1 to H6, H5 to H10 H1 & H10 208 H1 to H7, H4 to H10 H1 & H10 200 H1 to H8, H3 to H10 H1 & H10 190 H1 to H9 H2 to H10 H1 & H10 Secondary Voltage Interconnect Connect Lines to 220 X2 to X3 X1 & X4 110-0-110 X2 to X3 X2 to X1, X2 & X4 110 X1 to X3 X2 to X4 X1 & X4 HS14 Series = Earth Ground Note: Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject to change without notice. Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 231 5 Non-Ventilated Automation Transformers Electrical Connections (Three Phase) 240 Volt Primary 208Y/120 Volt Secondary Taps: 2, 5% FCBN 25 H1 208 Volt Primary 208Y/120 Volt Secondary Taps: 2, 5% FCBN 26 27 H1 8 5 2 96 3 H3 H2 8 5 2 74 1 X1 X3 X2 H3 X1 X3 X2 96 3 SHIELD X0 X1 X3 X2 H3 H1 Connect Lines To 240 1-H1 & 2-H2 & 3-H3 H1, H2, H3 4-H1 & 5-H2 & 6-H3 H1, H2, H3 216 7-H1 & 8-H2 & 9-H3 H1, H2, H3 Secondary Voltage Connect Lines To 208 X1, X2, & X3 120 X0, X1, X2, X3 Primary Voltage H1 Connect Taps 28 Primary Voltage Interconnect Connect Lines to 208 1-H1 & 2-H2 & 3-H3 H1, H2, H3 480 1-H1 & 2-H2 & 3- H3 H1, H2, H3 4-H1 & 5-H2 & 6-H3 H1, H2, H3 456 4-H1 & 5-H2 & 6- H3 H1, H2, H3 187 7-H1 & 8-H2 & 9-H3 H1, H2, H3 432 7-H1 & 8-H2 & 9- H3 H1, H2, H3 Connect Lines To Secondary Voltage 208 X1, X2, & X3 208 X1, X2, & X3 120 X0, X1, X2, X3 120 X0, X1, X2, X3 H1 29 H3 H2 8 5 2 9 6 3 Connect Lines to HT1 Series 480 Volt Primary 380Y/220 Volt Secondary Taps: 2, 5% FCBN 74 1 8 5 2 X3 198 H3 H2 H3 Connect Lines To HT3 Series 480 Volt Primary 240 w/120 CT Volt Secondary Taps: 2, 5% FCBN X0 X1 X3 Secondary Voltage HT6 Series X2 H2 X0 X1 228 H1 X2 H2 X3 Connect Taps 74 1 8 5 2 74 1 SHIELD X0 X0 X1 Primary Voltage H3 H2 X2 H2 H1 H1 96 3 SHIELD X0 27 H3 H2 74 1 480 Volt Primary 208Y/120 Volt Secondary Taps: 2, 5% FCBN 96 3 SHIELD SHIELD X0 X6 X1 X3 X2 X3 X2 H2 X1 X2 H2 X2 X0 X1 H1 H3 X3 X1 H1 X6 Primary Voltage Connect Taps Connect Lines To 480 1-H1 & 2-H2 & 3-H3 H1, H2, H3 456 4-H1 & 5-H2 & 6-H3 H1, H2, H3 432 Secondary Voltage 7-H1 & 8-H2 & 9-H3 Interconnect 240 120-0-120 Connect Lines To X1, X2, X3 X6 to HT5 Series 232 H1, H2, H3 X1-X6-X3 H3 X3 Primary Voltage Interconnect Connect Lines to 480 1-H1 & 2-H2 & 3-H3 H1, H2 & H3 456 4-H1 & 5-H2 & 6-H3 H1, H2 & H3 432 7-H1 & 8-H2 & 9-H3 H1, H2 & H3 Secondary Voltage Interconnect Connect Lines to 380 X1, X2, X3 220 X0, X1, X2, X3 HT79 Series = Earth Ground Notes: Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject to change without notice. Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 5 Non-Ventilated Automation Transformers Electrical Connections (Three Phase) 600 Volt Primary 208Y/120 Volt Secondary Taps: 2, 5% FCBN H1 30 H3 H2 8 5 2 74 1 208 Volt Primary 480Y/277 Volt Secondary Taps: 2, 5% FCBN 8 5 2 74 1 X3 X2 X1 96 3 31 X1 X3 X2 H1 Primary Voltage H0 H1 H3 Connect Taps H3 H2 SHIELD X1 H1 X3 H3 H2 H2 X2 H0 H1 H0 H1 X3 H0 H2 X2 X0 X1 96 3 SHIELD X2 H2 8 5 2 74 1 X3 X2 X1 96 3 SHIELD X0 32 240 Volt Primary 480Y/277 Volt Secondary Taps: 2, 5% FCBN X1 H3 X3 H3 Line Leads Primary Voltage Connect Taps Line Leads Primary Voltage Connect Taps Line Leads 208 1-X1 & 2-X2 & 3-X3 X1, X2, X3 240 1-X1 & 2-X2 & 3-X3 X1, X2, X3 600 1-H1 & 2-H2 & 3-H3 H1, H2, H3 570 4-H1 & 5-H2 & 6-H3 H1, H2, H3 198 4-X1 & 5-X2 & 6-X3 X1, X2, X3 228 4-X1 & 5-X2 & 6-X3 X1, X2, X3 540 7-H1 & 8-H2 & 9-H3 H1, H2, H3 187 7-X1 & 8-X2 & 9-X3 X1, X2, X3 216 7-X1 & 8-X2 & 9-X3 X1, X2, X3 Line Leads Secondary Voltage Line Leads Secondary Voltage 208 X1, X2, X3 480 H1, H2, H3 480 H1, H2, H3 120 X0, X1, X2, X3 277 H0, H1, H2, H3 277 H0, H1, H2, H3 Secondary Voltage HT7 Series HT84 Series Line Leads HT85 Series Notes: Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject to change without notice. Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. 233