Insulation Resistance: ? 10^9 Ohm
Mating Cycles: = 100
Ambient Temperature (Operation)*: - 40 °C - + 90 °C
Protection Degree / IP Rating**: IP65, IP67
Design Standard: IEC 61076-2-101
Pollution Degree: 3 acc. to DIN EN 60664-1 (VDE 0110-1)
Overvoltage Category: III acc. to DIN EN 60664-1 (VDE 0110-1)
Materials
Contact Base Material: CuZn
Contact Plating: Cu/Au
Contact Bearer Material: TPU
Contact Bearer Color: Black
Flammability Class (Contact Bearer): UL 94 HB
Molded Body Material: TPU
Molded Body Color: Orange
Flammability Class (Molded Body): UL 94 HB
Attachment Material: CuZn
Attachment Plating: Nickel-plated
Shielding Material: CuZn, tin-plated
O-Ring Material: FKM, green
Additional Technical Data
Fastening Torque (Attachment): M 12x1: (50-60) Ncm, hand-tight
Cable Data
Cable Number: 184
Conductor Size: 0.25 mm²
Number of Wires: 8
Minimal Bending Radius (Fixed Inst): ? 5 x D
Minimal Bending Radius (Flexible Inst): ? 10 x D
Conductor material: Cu
Cable Jacket Material: PVC
Cable Jacket Color: orange
Cable Diameter D: ø 6.6 ± 0.20 mm
Wire Insulation Material: PVC
Insulated Wire Diameter: ø 1.30 mm
Overall Shield (Cable): C-Shield
Ambient Temperature (Fixed Installation): - 40 °C - + 105 °C
Ambient Temperature (Flex Installation): + 5 °C - + 105 °C
Flammability Class (Cable Jacket): IEC 60332-1 , VDE 0482-265-2-1 , EN 50265-2-1
Cable Characteristics: Mainly plasticizer diffusion free; Exclusion of silicone
Safety & Environmental Compliance
RoHS Compliant: yes
Resistances
Oil Resistance: Good chemical and oil resistance
Notes
Note Derating: Notice derating
Protection Degree / IP Rating Note: ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
Note: Do not connect or disconnect under load.
Variants
Item # Item Description Cable Length Rated Current Contact Bearer Color
11423 RKTS 8-184/2 M 2 m 2 A Black
11424 RKTS 8-184/5 M 5 m 2 A Black
17567 RKTS 8-184/20 M 20 m 2 A Black