AOZ1019-EVA EZBuckTM 2A Simple Buck Regulator Evaluation Board Note General Description Features The AOZ1019 evaluation board is a fully assembled and tested circuit board built with the AOZ1019 buck regulator IC. It outputs a preset or adjustable voltage and up to 2A of continuous current. The evaluation board requires an input voltage from 4.5V to 16V. The output voltage is preset and can be adjusted from 0.8V to VIN-0.4V The AOZ1019-EVA circuit features include; current limit, short circuit protection, input under voltage lock out, internal soft start and thermal shut down. It operates at a fixed 500kHz switching frequency. The current mode control and integrated internal MOSFET minimize component count, board area and total cost. Applications The AOZ1019 comes in an SO-8 package and is rated over a -40C to +85C ambient temperature range. 4.5V to 16V operating input voltage range Output voltage was preset to 3.3V, adjustable down to 0.8V 2A continuous output current Fixed 500kHz PWM operation Internal soft start Cycle-by-cycle current limit Short-circuit protection Thermal shutdown Point of load DC/DC conversion PCIe graphics cards Set top boxes DVD drives and HDD LCD panels Cable modems Telecom/networking/datacom equipment Evaluation Board Schematic VIN C1 22F Ceramic C6 1F VIN From PC L1 4.7H EN AOZ1019 C5 @2A COMP C4 RC CC VOUT +3.3V Output LX R1 FB AGND PGND D1 C2, C3 22F Ceramic R2 Figure 1. Rev. 1.0 October 2007 www.aosmd.com Page 1 of 4 AOZ1019-EVA Component List Ref Designation Value Description Manufacturer Part Number C1 22F Ceramic Cap, 22F, 25V, 1210, X5R GRM32ER61E226KE15L C2 22F Ceramic Cap, 22F, 25V, 1210, X5R GRM32ER61E226KE15L C3 22F Ceramic Cap, 22F, 25V, 1210, X5R GRM32ER61E226KE15L C4 NU C5 1000pF Ceramic Cap, 1000pF, 50V, 0603, X7R GRM188R71E102K Manufacturer Murata C6 1F Ceramic Cap, 1F, 25V, 0603, X5R GRM188R61E105KA12D CC 1000pF Ceramic Cap, 1000pF, 50V, 0603, X7R GRM188R71E102K R1(1) 31.6k Thick Film Res, 1%, 31.6k, 0603 CRCW060331K6FKTAP R2 20k Thick Film Res, 1%, 20k, 0603 CRCW060321K0FKTAP RC 20k Thick Film Res, 1%, 20k, 0603 CRCW060321K0FKTAP L1 4.7H Inductor, 4.7H, 2.9A LQH55DN3R3M03 Murata Schottky Barrier Diode, 2A, 30V, SMA B230A-FDICT-ND DIODES Buck Regulator IC, 2A, 16V AOZ1019AI AOS D1 U1 AOZ1019AI DALE Note: 8 + ( 10 x V O ) - . Table 1 shows that the value of R1 with typical output voltages. 1. Output voltage is set by R1; R1 = ---------------------------------0.8k Table 1. VO (V) R1 (k) 1.2 4.99 1.8 12.7 2.5 21.5 3.3 31.6 5.0 52.3 Rev. 1.0 October 2007 www.aosmd.com Page 2 of 4 AOZ1019-EVA PCB Layout Figure 1. Top Silk Screen Figure 2. Top Layer Figure 3. Bottom Layer Rev. 1.0 October 2007 www.aosmd.com Page 3 of 4 AOZ1019-EVA Quick Start Guide 1. Connect the terminals of load to +VOUT pins and GND pins. Set load current to between 0A and 2A. 2. Connect the DC power supply to +VIN pin and GND pins. Set DC power supply voltage to between 4.5V and 16V. 3. Connect EN pin to +VIN or any voltage source which is higher than 2V and less than 16V. 4. Turn on DC power supply and evaluation circuit will start. 5. Measure input voltage at the +VIN pin and GND pins to eliminate the effect of voltage drop on wire between DC power supply and evaluation board. 6. Measure output voltage at the +VOUT pin and GND pins to eliminate the effect of voltage drop on wire between load and evaluation board. 7. Use an oscilloscope to monitor input ripple voltage right across input capacitor C1. 8. Use an oscilloscope to monitor output ripple voltage right across output capacitor C2. This datasheet contains preliminary data; supplementary data may be published at a later date. Alpha & Omega Semiconductor reserves the right to make changes at any time without notice. LIFE SUPPORT POLICY ALPHA & OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. Rev. 1.0 October 2007 2. A critical component in any component of a life support, device, or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.aosmd.com Page 4 of 4