ACDC
Specification
20/40 Watts
•Ultra Compact Size
•Single Outputs from 3.3 to 48 V
•Encapsulated
•PCB & Chassis Mount Versions
•<0.3 W No Load Input Power
•Peak Load Capability
•3 Year Warranty
ECE Series
Input
Input Voltage • 85-264 VAC (120-370 VDC) derate load
from 100% at 90 VAC to 90% at 85 VAC
Input Frequency • 47-63 Hz
Input Current • ECE20: 0.3 A rms at 230 VAC
ECE40: 0.5 A rms at 230 VAC
Inrush Current • 20 A at 115 VAC, 40 A at 230 VAC,
cold start at 25 °C
Power Factor • EN61000-3-2 Class A
Earth Leakage Current • Class II construction no earth
No Load Input Power • <0.3 W
Input Protection • ECE20: Internal T1 A/250 VAC fuse
ECE40: Internal T2 A/250 VAC fuse
Output
Output Voltage • See tables
Initial Set Accuracy • ±1%
Minimum Load • No minimum load required
Start Up Delay • 2 s max
Start Up Rise Time • 16 ms max
Hold Up Time • 8 ms minimum at full load & 115 VAC
Line Regulation • ±0.5% max
Load Regulation • ±1% max, ±2% max for ECE40US03/05-S
Transient Response • 4% max deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise • 3.3-5 V versions: 60 mV pk-pk,
3.3-5 V ‘ECE40-S’ versions: 75 mV
pk-pk (see note 5), all other models 1%
pk-pk max 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, 195-216% Vnom
ECE20US03 / ECE40US03
Overload Protection • 110-180%
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature • 0.05%/°C
Coefficient
xppower.com
General
Efficiency • See tables
Isolation • 3000 VAC Input to Output
Switching Frequency • 70 kHz typical
Power Density • ECE20: 9.97 W/In3
ECE40: 7.82 W/In3
MTBF • >450 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -25 °C to +70 °C, derate linearly from
100% at +50 °C to 50% at +70 °C
Cooling • Convection-cooled
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude • 3000 m
Vibration • 2 g, 10 Hz to 500 Hz, 10 mins/cycle,
60 mins each cycle
EMC & Safety
Emissions • EN55022, level B conducted & radiated
Harmonic Currents • EN61000-3-2, EN61000-3-3
ESD Immunity • EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity • EN61000-4-3, 10 V/m 80% mod
Perf Criteria A
EFT/Burst • EN61000-4-4, level 3 Perf Criteria A
Surge • EN61000-4-5, installation Class 3,
Perf Criteria A
Conducted Immunity • EN61000-4-6, 10 Vrms Perf Criteria A
Magnetic Fields • EN61000-4-8, 10 A/m Perf Criteria A
Dips & Interruptions • EN61000-4-11, 30% for 10 ms,
60% for 100 ms, 100% for 5000 ms
Perf Criteria A, B, B
Safety Approvals • EN60950-1, UL60950-1,
CSA22.2 No. 234 per cUL