MDR-60 60W Single Output Industrial DIN Rail Power Supply series Features : Universal AC input/Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 Class I, Div 2 Hazardous Locations T4 LED indicator for power on DC OK relay contact No load power consumption<0.75W 100% full load burn-in test 3 years warranty Bauar t gepruft Sicherheit egel ma ge od o s be wac g SPECIFICATION UL62368-1 MODEL MDR-60-24 MDR-60-48 DC VOLTAGE 5V 12V 24V 48V RATED CURRENT 10A 5A 2.5A 1.25A CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A 0 ~ 1.25A RATED POWER 50W 12 ~ 15V 24 ~ 30V 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.5% 1.0% 1.0% 1.0% 88% 87% Note.5 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 78% 1.8A/115VAC 1A/230VAC COLD START 30A/115VAC 60A/230VAC <1mA / 240VAC WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING NOTE 20ms/115VAC at full load 120 ~ 370VDC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) FUNCTION DC OK SIGNAL IEC62368-1 500ms, 30ms/115VAC at full load EFFICIENCY (Typ.) OVER VOLTAGE OTHERS 60W 1.0% 5 ~ 6V PROTECTION (Note 4) 60W 150mVp-p VOLTAGE TOLERANCE Note.3 2.0% VOLTAGE ADJ. RANGE OVERLOAD EMC 60W 120mVp-p 200mVp-p 48 ~ 56V LEAKAGE CURRENT SAFETY & EN62368-1 MDR-60-12 SETUP, RISE TIME INPUT www.tuv.com ID 2000000000 TPTC004 MDR-60-5 RIPPLE & NOISE (max.) Note.2 80mVp-p OUTPUT R33100 RoHS 86% 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6.25 ~ 7.25V 15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover Relay contact rating(max.): 30V/1A resistive -20 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 50) Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 UL508, UL62368-1, TUV EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A, EAC TP TC 020 299.2K hrs min. MIL-HDBK-217F (25) 40*90*100mm (W*H*D) 0.33Kg; 42pcs/14.8Kg/0.82CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:MDR-60-SPEC 2020-10-20 MDR-60 60W Single Output Industrial DIN Rail Power Supply Mechanical Specification Case No.962A 35 40 series Unit:mm 100 5 5 5 5 5 +V +V -V -V DC OK DC OK + 90 +V ADJ N L 7.5 7.5 Install DIN rail TS35/7.5 or TS35/15 Block Diagram fosc : 60KHz DC OK RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V O.C.P. DETECTION CIRCUIT FG CONTROL O.L.P. O.V.P. DC OK Relay Contact Contact Close PSU turns on / DC OK. Contact Open PSU turns off / DC Fail. Contact Ratings (max.) 30V/1A resistive load. Derating Curve Output Derating VS Input Voltage 100 100 12V,24V,48V 90 80 80 70 50 5V LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 45 55 AMBIENT TEMPERATURE () 60 70 (VERTICAL) 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:MDR-60-SPEC 2020-10-20